Abstract
STUDY DESIGN: Accuracy requirement analysis for image-guided pedicle screw placement. OBJECTIVES: To derive theoretical accuracy requirements for image-guided spinal pedicle screw placement. SUMMARY OF BACKGROUND DATA: Underlying causes of inaccuracy in image-guided surgical systems and methods for quantifying this inaccuracy have been studied. However, accuracy requirements for specific spinal surgical procedures have not been delineated. In particular, the accuracy requirements for image-guided spinal pedicle screw placement have not been previously reported. METHODS: A geometric model was developed relating spinal pedicle anatomy to accuracy requirements for image-guided surgery. This model was used to derive error tolerances for pedicle screw placement when using clinically relevant screw diameters in the cervical (3.5 mm), thoracic (5.0 mm), and thoracolumbar spine (6.5 mm). The error tolerances were represented as the permissible rotational and translational deviations from the ideal screw trajectory that would avoid pedicle wall perforation. The relevant dimensions of the pedicle model were extracted from existing morphometric data. RESULTS: As anticipated, accuracy requirements were greatest at spinal levels where the relevant screw diameter approximated the dimensions of the pedicle. These requirements were highest for T5, followed in descending order by T4, T7, T6, T3, T12, L1, T8, T11, C4, L2, C3, T10, C5, T2, T9, C6, L3, C2, T1, C7, L4, and L5. Maximum permissible translational/rotational error tolerances ranged from 0.0 mm/0.0 degrees at T5 to 3.8 mm/12.7 degrees at L5. CONCLUSIONS: These results, obtained by mathematical analysis, demonstrate that extremely high accuracy is necessary to place pedicle screws at certain levels of the spine without perforating the pedicle wall. These accuracy requirements exceed the accuracy of current image-guided surgical systems, based on clinical utility errors reported in the literature. In actual use, however, these systems have been shown to improve the accuracy of pedicle screw placement. This dichotomy indicates that other factors, such as the surgeon's visual and tactile feedback, may be operative.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Esses, S. I., Sachs, B. L., & Dreyzin, V. (1993) · Spine · doi:10.1097/00007632-199311000-00015 · Cited by 706 · cited 1×
“Anatomic and clinical studies in which conventional surgical techniques were used have reported pedicle screw misplacement rates from 5% to 41% for lumbar screws and 3% to 55% for thoracic screws.(6,10,11,21,26,27,36,43,49,51,52) These high misplacement rates are consistent with the low geometric error tolerances deri…”
ResultWEINSTEIN, J. N., SPRATT, K. F., SPENGLER, D., BRICK, C., & REID, S. (1988) · Spine · doi:10.1097/00007632-198809000-00008 · Cited by 532
Cervical Human Vertebrae Quantitative Three-Dimensional Anatomy of the Middle and Lower Regions
PANJABI, M. M., DURANCEAU, J., GOEL, V., OXLAND, T., & TAKATA, K. (1991) · SPINE · doi:10.1097/00007632-199108000-00001 · Cited by 463
Thoracic Human Vertebrae Quantitative Three-Dimensional Anatomy
PANJABI, M. M., TAKATA, K., GOEL, V., FEDERICO, D., OXLAND, T., DURANCEAU, J., & KRAG, M. (1991) · SPINE · doi:10.1097/00007632-199108000-00006 · Cited by 396
Accuracy of Computer-Assisted Pedicle Screw Placement: An In Vivo Computed Tomography Analysis
Schwarzenbach, O., Berlemann, U., Jost, B., Visarius, H., Arm, E., Langlotz, F., Nolte, L.-P., & Ozdoba, C. (1997) · Spine · doi:10.1097/00007632-199702150-00020 · Cited by 284
Laine, T., Schlenzka, D., Mäkitalo, K., Tallroth, K., Nolte, L.-P., & Visarius, H. (1997) · Spine · doi:10.1097/00007632-199706010-00018 · Cited by 277
Pedicle Screw Placement Using Image Guided Techniques
Merloz, P., Tonetti, J., Pittet, L., Coulomb, M., Lavalle??, S., & Sautot, P. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199809000-00006 · Cited by 260
Application of frameless stereotaxy to pedicle screw fixation of the spine
Kalfas, I. H., Kormos, D. W., Murphy, M. A., McKenzie, R. L., Barnett, G. H., Bell, G. R., Steiner, C. P., Trimble, M. B., & Weisenberger, J. P. (1995) · Journal of Neurosurgery · doi:10.3171/jns.1995.83.4.0641 · Cited by 247
Image-Guided Insertion of Transpedicular Screws: A Laboratory Set-Up
Nolte, L.-P., Zamorano, L. J., Jiang, Z., Wang, Q., Langlotz, F., & Berlemann, U. (1995) · Spine · doi:10.1097/00007632-199502001-00016 · Cited by 197
Foley, K. T., & Smith, M. M. (1996) · Neurosurgery Clinics of North America · doi:10.1016/s1042-3680(18)30385-1 · Cited by 195
Self-citationPlanning and Insertion of Pedicle Screws with Computer Assistance
Berlemann, U., Monin, D. L., Arm, E., Nolte, L. –., & Ozdoba, C. (1997) · Journal of Spinal Disorders · doi:10.1097/00002517-199704000-00004 · Cited by 72
Image-Guided Computer-Assisted Spine Surgery: A Pilot Study on Pedicle Screw Fixation
Nolte, L. P., Zamorano, L. J., Arm, E., Visarius, H., Jiang, Z., Berlerman, U., & Schwarzenbach, O. (1996) · Stereotactic and Functional Neurosurgery · doi:10.1159/000099677 · Cited by 62
Medical Imaging and Registration in Computer Assisted Surgery
Simon, D. A., & e, S. P. L. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199809000-00004 · Cited by 43 · cited 1×
“Multiple sources of error for image-guided systems have been documented.(17,20,46,47) Many qualitative and quantitative studies have reported the accuracy of image-guided surgical systems for performing various spinal surgical procedures.”
BackgroundSelf-citationA New Halo-Vest: Rationale, Design and Biomechanical Comparison to Standard Halo-Vest Designs
Krag, M. H., & Beynnon, B. D. (1988) · Spine · doi:10.1097/00007632-198803000-00002 · Cited by 28
Cited by
Free Hand Pedicle Screw Placement in the Thoracic Spine: Is it Safe?
Kim, Y. J., Lenke, L. G., Bridwell, K. H., Cho, Y. S., & Riew, K. D. (2004) · Spine · doi:10.1097/01.brs.0000109983.12113.9b · Cited by 706
Rajasekaran, S., Vidyadhara, S., Ramesh, P., & Shetty, A. P. (2007) · Spine · doi:10.1097/01.brs.0000252094.64857.ab · Cited by 358
Standardized evaluation methodology for 2-D-3-D registration
van de Kraats, E. B., Penney, G. P., Tomazevic, D., van Walsum, T., & Niessen, W. J. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.853240 · Cited by 211
“8 mm [37] in different levels of the spine.”
BackgroundImage-guided spine surgery: state of the art and future directions
Tjardes, T., Shafizadeh, S., Rixen, D., Paffrath, T., Bouillon, B., Steinhausen, E. S., & Baethis, H. (2010) · European Spine Journal · doi:10.1007/s00586-009-1091-9 · Cited by 206
“[83] raises another intriguing question concerning the neuropsychological basis of image-guided surgery, i.”
Background3-D/2-D registration of CT and MR to X-ray images
Tomazevic, D., Likar, B., Slivnik, T., & Pernus, F. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819277 · Cited by 167
“[29] reported the following maximum permissible translational (rotational) errors: 0.”
BackgroundResultInfluential
Metadata
- Authors
- Rampersaud, Y. R., Simon, D. A., & Foley, K. T.
- Venue
- Spine
- Published
- 2001-02
- Volume
- 26
- Issue
- 4
- Pages
- 352-359
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2072547850
- Cited by
- 224
- References
- 14
- FWCI
- 8.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.