STUDY DESIGN: Accuracy requirement analysis for image-guided pedicle screw placement. OBJECTIVES: To derive theoretical accuracy requirements for image-guided spinal pedicle screw placement. SUMMARY OF BACKGROUND DATA: Underlying causes of inaccuracy in image-guided surgical systems and methods for quantifying this inaccuracy have been studied. However, accuracy requirements for specific spinal surgical procedures have not been delineated. In particular, the accuracy requirements for image-guided spinal pedicle screw placement have not been previously reported. METHODS: A geometric model was developed relating spinal pedicle anatomy to accuracy requirements for image-guided surgery. This model was used to derive error tolerances for pedicle screw placement when using clinically relevant screw diameters in the cervical (3.5 mm), thoracic (5.0 mm), and thoracolumbar spine (6.5 mm). The error tolerances were represented as the permissible rotational and translational deviations from the ideal screw trajectory that would avoid pedicle wall perforation. The relevant dimensions of the pedicle model were extracted from existing morphometric data. RESULTS: As anticipated, accuracy requirements were greatest at spinal levels where the relevant screw diameter approximated the dimensions of the pedicle. These requirements were highest for T5, followed in descending order by T4, T7, T6, T3, T12, L1, T8, T11, C4, L2, C3, T10, C5, T2, T9, C6, L3, C2, T1, C7, L4, and L5. Maximum permissible translational/rotational error tolerances ranged from 0.0 mm/0.0 degrees at T5 to 3.8 mm/12.7 degrees at L5. CONCLUSIONS: These results, obtained by mathematical analysis, demonstrate that extremely high accuracy is necessary to place pedicle screws at certain levels of the spine without perforating the pedicle wall. These accuracy requirements exceed the accuracy of current image-guided surgical systems, based on clinical utility errors reported in the literature. In actual use, however, these systems have been shown to improve the accuracy of pedicle screw placement. This dichotomy indicates that other factors, such as the surgeon's visual and tactile feedback, may be operative.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00007632-200102150-00010

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

Metadata

Authors
Rampersaud, Y. R., Simon, D. A., & Foley, K. T.
Venue
Spine
Published
2001-02
Volume
26
Issue
4
Pages
352-359
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2072547850
Cited by
224
References
14
FWCI
8.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.