Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Task Force II: Blood pressure measurement and cardiovacular outcome

Staessen, Jan A., Asmar, Roland, De Buyzere, Marc, Imai, Yutaka, Parati, Gianfranco, Shimada, Kazayuki, Stergiou, George, Redón, Josep, Verdecchia, Paolo·2001·Blood Pressure Monitoring

Abstract

OBJECTIVE: To reach a consensus on the prognostic significance of new techniques of automated blood pressure measurement. METHODS: A Task Force on the prognostic significance of ambulatory blood pressure monitoring wrote this review in preparation for the Eighth International Consensus Conference (28-31 October 2001, Sendai, Japan). This synopsis was amended to account for opinions aired at the conference and to reflect the common ground reached in the discussions. POINTS OF CONSENSUS: (1) Prospective studies in treated and untreated hypertensive patients and in the general population have demonstrated that, even after adjusting for established risk factors, the incidence of cardiovascular events is correlated with blood pressure on conventional as well as ambulatory measurement. Ambulatory monitoring, however, significantly refines the prediction already provided by conventional blood pressure measurement. (2) White-coat hypertension is usually defined as an elevated clinic blood pressure in the presence of a normal daytime ambulatory blood pressure. Event-based studies in hypertensive patients have convincingly demonstrated that the risk of cardiovascular disease is less in patients with white-coat hypertension than in those with higher ambulatory blood pressure levels even after controlling for concomitant risk factors. Based on prognostic evidence, white-coat hypertension can now be defined as a conventional blood pressure that is persistently equal to or greater than 140/90 mmHg with an average daytime ambulatory blood pressure of below 135/85 mmHg. The issue of whether or not white-coat hypertension predisposes to sustained hypertension needs further research. (3) There is a growing body of evidence showing that a decreased nocturnal fall in blood pressure (<10% of the daytime level) is associated with a worse prognosis, irrespective of whether night-time dipping is studied as a continuous or a class variable. (4) Intermittent techniques of ambulatory blood pressure monitoring are limited in terms of quantifying short-term blood pressure variability. Proven cardiovascular risk factors such as old age, a higher than usual blood pressure and diabetes mellitus are often associated with greater short-term blood pressure variability. After adjusting for these risk factors, some - but not all - studies have nevertheless reported an independent and positive relationship between cardiovascular outcome and measures of variability of daytime and night-time blood pressure, for example standard deviation. (5) Reference values for ambulatory blood pressure measurement in children are currently based on statistical parameters of blood pressure distribution. In children and adolescents, functional rather than distribution-based definitions of ambulatory hypertension have yet to be developed. (6) Several studies of gestational hypertension have shown that, compared with office measurement, ambulatory blood pressure monitoring is a better predictor of maternal and fetal complications. Pregnancy is a special indication for ambulatory monitoring so that the white-coat effect can be measured and pregnant women are not given antihypertensive drugs unnecessarily. (7) Ambulatory pulse pressure and the QKD interval are measurements obtained by ambulatory monitoring that to some extent reflect the functional characteristics of the large arteries. The QKD interval is correlated with left ventricular mass, and ambulatory pulse pressure is a strong predictor of cardiovascular outcome. (8) Under standardized conditions, the self-measurement of blood pressure is equally as effective as ambulatory blood pressure monitoring in identifying the white-coat effect, but further studies are required to elucidate fully the prognostic accuracy of self-measured blood pressure in comparison with conventional and ambulatory blood pressure measurement. CONCLUSIONS: Ambulatory blood pressure measurement refines the prognostic information provided by conventional blood pressure readings obtained in the clinic or the doctor's office. Longitudinal studies of patients with white-coat hypertension should clarify the transient, persistent or progressive nature of this condition, particularly in paediatric patients, in whom white-coat hypertension may be a harbinger of sustained hypertension and target-organ damage in adulthood. Finally, the applicability, cost-effectiveness and long-term prognostic accuracy of the self-measurement of blood pressure should be evaluated in relation to conventional blood pressure measurement and ambulatory monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00126097-200112000-00016

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 187

Metadata

Authors
Staessen, J. A., Asmar, R., De Buyzere, M., Imai, Y., Parati, G., Shimada, K., Stergiou, G., Redón, J., & Verdecchia, P.
Venue
Blood Pressure Monitoring
Published
2001-12
Volume
6
Issue
6
Pages
355-370
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2038526565
Cited by
187
References
8
FWCI
5.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Task Force II: Blood pressure measurement and cardiovacular outcome. https://app.cochat.ai/papers/10.1097/00126097-200112000-00016
The paper
Staessen, J. A., Asmar, R., De Buyzere, M., Imai, Y., Parati, G., Shimada, K., Stergiou, G., Redón, J., & Verdecchia, P. (2001). Task Force II: Blood pressure measurement and cardiovacular outcome. Blood Pressure Monitoring. https://doi.org/10.1097/00126097-200112000-00016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.