In Vivo Fluoroscopic Analysis of the Normal Human Knee
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
The objective of the current study was to use fluoroscopy and computed tomography to accurately determine the three-dimensional, in vivo, weightbearing kinematics of five normal knees. Three-dimensional computer-aided design models of each subject's femur and tibia were recreated from the three-dimensional computed tomography bone density data. Three-dimensional motions for each subject then were determined for five weightbearing activities. During gait, the lateral condyle experienced -4.3 mm (range, -1.9--10.3 mm) of average motion, whereas the medial condyle moved only -0.9 mm (range, 3.4--5.8 mm). One subject experienced 5.8 mm of medial condyle motion. On average, during deep flexion activities, subjects experienced -12.7 mm (range, 1.4--29.8 mm) of lateral condyle motion, whereas the medial condyle motion only was -2.9 mm (range, 3.0--9.0 mm). One subject experienced 5.8 and 9.0 mm of medial condyle motion during gait and a deep knee bend, respectively leading to the occurrence of a lateral pivot motion. During the deep flexion activities, the subjects experienced significantly more axial rotation (> 13 degrees) than gait (< 5 degrees). During all five activities, the lateral condyle experienced significantly more anteroposterior translation, leading to axial rotation of the tibia relative to the femur.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Markolf, K., Mensch, J., & Amstutz, H. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658050-00001 · Cited by 844
Three-dimensional kinematics of the human knee during walking
Lafortune, M. A., Cavanagh, P. R., Sommer, H. J., & Kalenak, A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90254-x · Cited by 694
Fukubayashi, T., Torzilli, P. A., Sherman, M. F., & Warren, R. F. (1982) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198264020-00018 · Cited by 554
Patient outcomes following tricompartmental total knee replacement. A meta-analysis
Callahan, C. M. (1994) · JAMA · doi:10.1001/jama.271.17.1349 · Cited by 506
Stabilizing mechanisms of the loaded and unloaded knee joint
Hsieh, H., & Walker, P. (1976) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197658010-00016 · Cited by 376
Justification of triaxial goniometer for the measurement of joint rotation
Chao, E. Y. S. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90044-5 · Cited by 355
Knee biomechanics and total knee replacement
Andriacchi, T. P., Stanwyck, T. S., & Galante, J. O. (1986) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(86)80033-x · Cited by 197
In Vivo Kinematic Analysis of a Mobile Bearing Total Knee Prosthesis
Stiehl, J. B., Dennis, D. A., Komistek, R. D., & Keblish, P. A. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199712000-00010 · Cited by 185
Self-citationInteraction between intrinsic knee mechanics and the knee extensor mechanism
Draganich, L. F., Andriacchi, T. P., & Andersson, G. B. J. (1987) · Journal of Orthopaedic Research · doi:10.1002/jor.1100050409 · Cited by 182
Hoff, W. A., Komistek, R. D., Dennis, D. A., Gabriel, S. M., & Walker, S. A. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00009-6 · Cited by 178
Self-citationComprehensive gait analysis in posterior-stabilized knee arthroplasty
Wilson, S. A., McCann, P. D., Gotlin, R. S., Ramakrishnan, H. K., Wootten, M. E., & Insall, J. N. (1996) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(96)80023-4 · Cited by 140
Kärrholm, J., Jonsson, H., Nilsson, K. G., & Söderqvist, I. (1994) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/bf01552655 · Cited by 80
Cited by
The movement of the normal tibio-femoral joint
Freeman, M. A. R., & Pinskerova, V. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.006 · Cited by 532
In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics
Dennis, D. A., Mahfouz, M. R., Komistek, R. D., & Hoff, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.042 · Cited by 302
Self-citationFeasibility of Using Orthogonal Fluoroscopic Images to Measure In Vivo Joint Kinematics
Li, Wuerz, & DeFrate, L. E. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1691448 · Cited by 192
Li, G., DeFrate, L. E., Sun, H., & Gill, T. J. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503262175 · Cited by 182
Fregly, B. J., Rahman, H. A., & Banks, S. A. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1933949 · Cited by 155
Metadata
- Authors
- Komistek, R. D., Dennis, D. A., & Mahfouz, M.
- Venue
- Clinical Orthopaedics & Related Research
- Published
- 2003-05
- Volume
- 410
- Issue
- 410
- Pages
- 69-81
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2069389983
- Cited by
- 436
- References
- 12
- FWCI
- 17.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.