Predicting Proximal Femoral Strength Using Structural Engineering Models
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Hip fracture related to osteoporosis and metastatic disease is a major cause of morbidity and mortality. An accurate and precise method of predicting proximal femoral strength and fracture location would be useful for research and clinical studies of hip fracture. The goals of this study were to develop a structural modeling technique that accurately predicts proximal femoral strength; to evaluate the accuracy and precision of this predicted strength on an independent data set; and to evaluate the ability of this technique to predict fracture location. Fresh human cadaveric proximal femora with and without metastatic lesions were studied using computed tomography scan-based three-dimensional structural models and mechanical testing to failure under single-limb stance-type loading. The models understated proximal femoral strength by an average of 444 N, and the precision of the predicted strength was +/- 1900 N. Therefore, the ability to predict hip strength in an individual subject is limited primarily by the level of precision, rather than accuracy. This level of precision is likely to be sufficient for many studies of hip strength. Finally, these models predict fractures involving the subcapital and cervical regions, consistent with most fractures produced experimentally under single-limb stance-type loading.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnosis of osteoporosis and assessment of fracture risk
Kanis, J. A. (2002) · The Lancet · doi:10.1016/s0140-6736(02)08761-5 · Cited by 2,260
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533 · cited 2×
“Trabecular bone is orthotropic(8,15) and cortical bone is transversely isotropic.(36) Bone is also weaker in tension than in compression.”
BackgroundMIRELS, H. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198912000-00027 · Cited by 1,214
Prediction of femoral fracture load using automated finite element modeling
Keyak, J. H., Rossi, S. A., Jones, K. A., & Skinner, H. B. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00123-1 · Cited by 682
Self-citationPredicting Femoral Neck Strength From Bone Mineral Data: A Structural Approach
BECK, T. J., RUFF, C. B., WARDEN, K. E., SCOTT, W. W., & RAO, G. U. (1990) · Investigative Radiology · doi:10.1097/00004424-199001000-00004 · Cited by 551
Musculo-skeletal loading conditions at the hip during walking and stair climbing
Heller, M. O., Bergmann, G., Deuretzbacher, G., Dürselen, L., Pohl, M., Claes, L., Haas, N. P., & Duda, G. N. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00039-2 · Cited by 446
Femoral strength is better predicted by finite element models than QCT and DXA
Cody, D. D., Gross, G. J., J. Hou, F., Spencer, H. J., Goldstein, S. A., & P. Fyhrie, D. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00099-8 · Cited by 440
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401
Survival and ambulation following hip fracture.
Miller, C. W. (1978) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197860070-00010 · Cited by 372
Mortality Risk After Hip Fracture
Richmond, J., Aharonoff, G. B., Zuckerman, J. D., & Koval, K. J. (2003) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200301000-00008 · Cited by 315
Cited by
Prediction of strength and strain of the proximal femur by a CT-based finite element method
Bessho, M., Ohnishi, I., Matsuyama, J., Matsumoto, T., Imai, K., & Nakamura, K. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.08.003 · Cited by 407
Schileo, E., Taddei, F., Cristofolini, L., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.009 · Cited by 373
Schileo, E., Dall’Ara, E., Taddei, F., Malandrino, A., Schotkamp, T., Baleani, M., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.05.017 · Cited by 372
Subject-specific finite element models can accurately predict strain levels in long bones
Schileo, E., Taddei, F., Malandrino, A., Cristofolini, L., & Viceconti, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.02.010 · Cited by 330
Keaveny, T. M., Donley, D. W., Hoffmann, P. F., Mitlak, B. H., Glass, E. V., & San Martin, J. A. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.061011 · Cited by 258
Nazarian, A., von Stechow, D., Zurakowski, D., Müller, R., & Snyder, B. D. (2008) · Calcified Tissue International · doi:10.1007/s00223-008-9174-x · Cited by 244
“From the mechanics of structures, the load-bearing capacity of a bone affected by metastatic cancer depends on the shape and cross-sectional geometry of that bone in addition to its material properties [2–9].”
BackgroundReduction in proximal femoral strength due to long-duration spaceflight
Keyak, J. H., Koyama, A. K., LeBlanc, A., Lu, Y., & Lang, T. F. (2009) · Bone · doi:10.1016/j.bone.2008.11.014 · Cited by 236
“For stance loading, a displacement vector oriented within the coronal plane and at 20° to the shaft axis was incrementally applied to the femoral head, and the distal end of the model was fully constrained [5].”
BackgroundMethodSelf-citationBisphosphonates as a supplement to exercise to protect bone during long-duration spaceflight
LeBlanc, A., Matsumoto, T., Jones, J., Shapiro, J., Lang, T., Shackelford, L., Smith, S. M., Evans, H., Spector, E., Ploutz-Snyder, R., et al. (2013) · Osteoporosis International · doi:10.1007/s00198-012-2243-z · Cited by 234
Self-citationBouxsein, M. L., Szulc, P., Munoz, F., Thrall, E., Sornay-Rendu, E., & Delmas, P. D. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.070309 · Cited by 217
Cohen, A., Dempster, D. W., Recker, R. R., Lappe, J. M., Zhou, H., Zwahlen, A., Müller, R., Zhao, B., Guo, X., Lang, T., et al. (2013) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2013-1047 · Cited by 206
Bousson, V., Le Le Bras, A., Roqueplan, F., Kang, Y., Mitton, D., Kolta, S., Bergot, C., Skalli, W., Vicaut, E., Kalender, W., et al. (2006) · Osteoporosis International · doi:10.1007/s00198-006-0074-5 · Cited by 189
“A mechanical testing procedure simulating the impact from a fall onto the greater trochanter would probably have produced a broader spectrum of fractures, with a larger proportion offractures involving the trochanteric region [31, 32 ].”
Liu, X. S., Cohen, A., Shane, E., Yin, P. T., Stein, E. M., Rogers, H., Kokolus, S. L., McMahon, D. J., Lappe, J. M., Recker, R. R., et al. (2010) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.111 · Cited by 186
“7 (SIMULIA) to determine stiffness, as described by Keyak and colleagues.((39))”
BackgroundMethodInfluentialOrwoll, E. S., Adler, R. A., Amin, S., Binkley, N., Lewiecki, E. M., Petak, S. M., Shapses, S. A., Sinaki, M., Watts, N. B., & Sibonga, J. D. (2013) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1948 · Cited by 184
Keyak, J. H., Sigurdsson, S., Karlsdottir, G., Oskarsdottir, D., Sigmarsdottir, A., Zhao, S., Kornak, J., Harris, T. B., Sigurdsson, G., Jonsson, B. Y., et al. (2011) · Bone · doi:10.1016/j.bone.2011.03.682 · Cited by 165
“From the baseline (pre-fracture) QCT data, we computed the strength of the left hip of each subject in the fracture and control groups using our FE modelingmethod [6,8,17,18].”
InfluentialSelf-citationAdvances in bone imaging for osteoporosis
Adams, J. E. (2013) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2012.217 · Cited by 165
Spaceflight-induced Bone Loss: Is there an Osteoporosis Risk?
Sibonga, J. D. (2013) · Current Osteoporosis Reports · doi:10.1007/s11914-013-0136-5 · Cited by 147
Sibonga, J., Matsumoto, T., Jones, J., Shapiro, J., Lang, T., Shackelford, L., Smith, S. M., Young, M., Keyak, J., Kohri, K., et al. (2019) · Bone · doi:10.1016/j.bone.2019.07.013 · Cited by 142
Self-citationTowards human exploration of space: the THESEUS review series on muscle and bone research priorities
Lang, T., Van Loon, J. J. W. A., Bloomfield, S., Vico, L., Chopard, A., Rittweger, J., Kyparos, A., Blottner, D., Vuori, I., Gerzer, R., et al. (2017) · npj Microgravity · doi:10.1038/s41526-017-0013-0 · Cited by 141
Adaptation of the Skeletal System During Long-Duration Spaceflight
Sibonga, J. D., Cavanagh, P. R., Lang, T. F., LeBlanc, A. D., Schneider, V. S., Shackelford, L. C., Smith, S. M., & Vico, L. (2007) · Clinical Reviews in Bone and Mineral Metabolism · doi:10.1007/s12018-008-9012-8 · Cited by 67
“Reductions in Whole Bone Strength A Finite Element Analysis [FEA] had been developed from three dimensional images of QCT hip scans to determine force to failure for loading of the femoral neck in two orientations: the posterior lateral direction (associated with backward falls to the side) and the axial direction (as…”
BackgroundInfluential
Metadata
- Authors
- Keyak, J. H., Kaneko, T. S., Tehranzadeh, J., & Skinner, H. B.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2005-08
- Volume
- &NA;
- Issue
- 437
- Pages
- 219-228
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2078515578
- Cited by
- 278
- References
- 31
- FWCI
- 6.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.