Clinical Accuracy of Fluoroscopic Computer-Assisted Pedicle Screw Fixation: A CT Analysis
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
In Brief Study Design. Observational cohort study with computerized tomography (CT) analysis of in vivo pedicle screw placement. Objective. To evaluate the clinical accuracy of computer-assisted fluoroscopy for the placement of thoracic and lumbosacral (LS) pedicle screws. Summary of Background Data. Computer-assisted fluoroscopy is an adjunct for the placement of pedicle screws. Methods. Postoperative CT of 360 titanium pedicle screws (281 LS [L1–S1]; 79 thoracic [T2–T12]) were independently assessed. All screws were placed using the FluoroNav™ system (Medtronic Surgical Navigation Technologies, Louisville, CO). The relative position of the screw to the pedicle was graded as follows: A = completely in; B = <2 mm breach; C = 2–4 mm breach; and D = >4 mm breach. If an osseous breach occurred, the direction of the breach was further classified. Results. Eight-five percent of screws were completely contained within the pedicle. Fifty-five-pedicle breaches (25 medial; 30 lateral) occurred. Pedicle breaches were graded B in 13.1% (47 breaches), C in 1.9% (7), and D in 0.3% (1) of screws. Pedicle breach was significantly higher in the thoracic compared to the LS spine, 31.6% (25/79) and 10.6% (30/281), respectively (P < 0.0001). In the thoracic spine, 72% of pedicle breaches were lateral. In 49% of breaches, the screw diameter was larger than the pedicle diameter. None of the pedicle breaches were associated with neurologic or other clinical sequelae. Conclusions. The clinical pedicle breach rate in this study is comparable to those reported using conventional techniques with or without fluoroscopic assistance. FluoroNav™ appears to be a safe adjunct for the placement of thoracic and LS pedicle screws. In this series of 360 pedicle screws (T2–S1) placed with the assistance of virtual fluoroscopy, 55 pedicle breaches occurred. The majority of breaches (86%) were minor (<2 mm). None of the pedicle breaches were associated with clinical sequelae. FluoroNav™ system (Medtronic Surgical Navigation Technologies, Louisville, CO) is a safe adjunct for the placement of pedicle screws.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accuracy of Pedicular Screw Placement In Vivo
GERTZBEIN, S. D., & ROBBINS, S. E. (1990) · Spine · doi:10.1097/00007632-199001000-00004 · Cited by 1,381 · cited 1×
“Clinically, encroachment of the epidural space up to 2 mm is conservatively considered to be safe in most cases.(2,3,8) Furthermore, although the use of CT analysis for pedicle screw placement has reasonable correlation with gross in vitro inspection, it can be associated with 1–2 mm of error due to metal artifact.”
BackgroundEsses, S. I., Sachs, B. L., & Dreyzin, V. (1993) · Spine · doi:10.1097/00007632-199311000-00015 · Cited by 706
Complications Associated with Pedicle Screws*
LONSTEIN, J. E., DENIS, F., PERRA, J. H., PINTO, M. R., SMITH, M. D., & WINTER, R. B. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199911000-00003 · Cited by 542
WEINSTEIN, J. N., SPRATT, K. F., SPENGLER, D., BRICK, C., & REID, S. (1988) · Spine · doi:10.1097/00007632-198809000-00008 · Cited by 532
Amiot, L.-P., Lang, K., Putzier, M., Zippel, H., & Labelle, H. (2000) · Spine · doi:10.1097/00007632-200003010-00012 · Cited by 450 · cited 2×
“3%, thoracic and lumbar) in the misplacement rates of pedicle screws.(1,9,22,25,27,29,31,32,36,37) In addition to improved accuracy, 3-D CAS systems reduce the range (i.”
BackgroundAccuracy of Computer-Assisted Pedicle Screw Placement: An In Vivo Computed Tomography Analysis
Schwarzenbach, O., Berlemann, U., Jost, B., Visarius, H., Arm, E., Langlotz, F., Nolte, L.-P., & Ozdoba, C. (1997) · Spine · doi:10.1097/00007632-199702150-00020 · Cited by 284 · cited 2×
“3%, thoracic and lumbar) in the misplacement rates of pedicle screws.(1,9,22,25,27,29,31,32,36,37) In addition to improved accuracy, 3-D CAS systems reduce the range (i.”
BackgroundLaine, T., Schlenzka, D., Mäkitalo, K., Tallroth, K., Nolte, L.-P., & Visarius, H. (1997) · Spine · doi:10.1097/00007632-199706010-00018 · Cited by 277 · cited 2×
“3%, thoracic and lumbar) in the misplacement rates of pedicle screws.(1,9,22,25,27,29,31,32,36,37) In addition to improved accuracy, 3-D CAS systems reduce the range (i.”
BackgroundPedicle Screw Placement Using Image Guided Techniques
Merloz, P., Tonetti, J., Pittet, L., Coulomb, M., Lavalle??, S., & Sautot, P. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199809000-00006 · Cited by 260 · cited 2×
“3%, thoracic and lumbar) in the misplacement rates of pedicle screws.(1,9,22,25,27,29,31,32,36,37) In addition to improved accuracy, 3-D CAS systems reduce the range (i.”
BackgroundApplication of frameless stereotaxy to pedicle screw fixation of the spine
Kalfas, I. H., Kormos, D. W., Murphy, M. A., McKenzie, R. L., Barnett, G. H., Bell, G. R., Steiner, C. P., Trimble, M. B., & Weisenberger, J. P. (1995) · Journal of Neurosurgery · doi:10.3171/jns.1995.83.4.0641 · Cited by 247 · cited 2×
“3%, thoracic and lumbar) in the misplacement rates of pedicle screws.(1,9,22,25,27,29,31,32,36,37) In addition to improved accuracy, 3-D CAS systems reduce the range (i.”
BackgroundStereotactic Navigation for Placement of Pedicle Screws in the Thoracic Spine
Youkilis, A. S., Quint, D. J., McGillicuddy, J. E., & Papadopoulos, S. M. (2001) · Neurosurgery · doi:10.1097/00006123-200104000-00015 · Cited by 232 · cited 1×
“3% and, in general, are less than those reported in this series.(1,9,22,25,27,29,31,32,36,37,49) In comparison to the use of conventional techniques with fluoroscopic or virtual fluoroscopic (2-D CAS) assistance, the use of 3-D CAS enables the real time visualization of pedicle specific axial, sagittal and coronal pla…”
Background
Cited by
Devito, D. P., Kaplan, L., Dietl, R., Pfeiffer, M., Horne, D., Silberstein, B., Hardenbrook, M., Kiriyanthan, G., Barzilay, Y., Bruskin, A., et al. (2010) · Spine · doi:10.1097/brs.0b013e3181d323ab · Cited by 407
Navigated Total Knee Replacement: A Meta-Analysis
Bauwens, K., Matthes, G., Wich, M., Gebhard, F., Hanson, B., Ekkernkamp, A., & Stengel, D. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200702000-00005 · Cited by 399
Mason, A., Paulsen, R., Babuska, J. M., Rajpal, S., Burneikiene, S., Nelson, E. L., & Villavicencio, A. T. (2014) · Journal of Neurosurgery: Spine · doi:10.3171/2013.11.spine13413 · Cited by 384
Rajasekaran, S., Vidyadhara, S., Ramesh, P., & Shetty, A. P. (2007) · Spine · doi:10.1097/01.brs.0000252094.64857.ab · Cited by 358
Navigation and Robotics in Spinal Surgery: Where Are We Now?
Overley, S. C., Cho, S. K., Mehta, A. I., & Arnold, P. M. (2017) · Neurosurgery · doi:10.1093/neuros/nyw077 · Cited by 327
Verma, R., Krishan, S., Haendlmayer, K., & Mohsen, A. (2010) · European Spine Journal · doi:10.1007/s00586-009-1258-4 · Cited by 242
“Thus, 23 publications [5, 6, 8, 9, 12–30] were analysed in this paper (Table 2; 2 randomised controlled trials, 12 case–control studies and 9 case series).”
BackgroundMethodVascular injury and complication in neurosurgical spine surgery
Inamasu, J., & Guiot, B. H. (2006) · Acta Neurochirurgica · doi:10.1007/s00701-005-0669-1 · Cited by 225
“improved following a better appreciation of surgical anatomy, as occurred in the cervical spine [10, 89].”
Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review
Aoude, A. A., Fortin, M., Figueiredo, R., Jarzem, P., Ouellet, J., & Weber, M. H. (2015) · European Spine Journal · doi:10.1007/s00586-015-3853-x · Cited by 223
Image-guided pedicle screw insertion accuracy: a meta-analysis
Tian, N.-F., & Xu, H.-Z. (2009) · International Orthopaedics · doi:10.1007/s00264-009-0792-3 · Cited by 220
Image-guided spine surgery: state of the art and future directions
Tjardes, T., Shafizadeh, S., Rixen, D., Paffrath, T., Bouillon, B., Steinhausen, E. S., & Baethis, H. (2010) · European Spine Journal · doi:10.1007/s00586-009-1091-9 · Cited by 206
“Generally, in the thoracic spine lateral pedicle breaches appear to be more common [22, 24, 82] than medial pedicle violation.”
BackgroundPerdomo-Pantoja, A., Ishida, W., Zygourakis, C., Holmes, C., Iyer, R. R., Cottrill, E., Theodore, N., Witham, T. F., & Lo, S.-F. L. (2019) · World Neurosurgery · doi:10.1016/j.wneu.2019.02.217 · Cited by 176
Metadata
- Authors
- Rampersaud, Y. R., Pik, J. H. T., Salonen, D., & Farooq, S.
- Venue
- Spine
- Published
- 2005-04
- Volume
- 30
- Issue
- 7
- Pages
- E183-E190
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W1968760086
- Cited by
- 160
- References
- 16
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.