A Prospective Randomized Study of Posterolateral Lumbar Fusion Using Osteogenic Protein-1 (OP-1) Versus Local Autograft With Ceramic Bone Substitute: Emphasis of Surgical Exploration and Histologic Assessment
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
STUDY DESIGN: A prospective, randomized and controlled study. OBJECTIVES: To evaluate the osteoinductive property of Osteogenic Protein-1 (OP-1 or BMP-7) and fusion rate in human instrumented posterolateral lumbar fusion through radiographic examination, surgical exploration, and histologic assessment. SUMMARY OF BACKGROUND DATA: The use of osteoinductive agents is a current topic in spinal fusion. Numerous preclinical investigations have demonstrated efficacy of osteoinductive proteins in spinal fusion, but few human clinical studies have been reported. METHODS: Nineteen patients with L3-L4 or L4-L5 degenerative spondylolisthesis underwent posterolateral lumbar fusion using pedicle screw instrumentation. The patients were randomized to receive either OP-1 Putty (3.5 mg OP-1/g of collagen matrix per side) alone (n = 9), or local autograft with HA-TCP granules (n = 10). Fusion status was evaluated using plain radiography and CT scan. Radiographic fusion criteria included less than 5 degrees of angular motion, less than 2 mm of translation, and evidence of bridging bone in the posterolateral lumbar area in which the graft materials were placed following decortication. After a minimum 1-year follow-up, the patients who showed radiographic evidence of fusion underwent instrumentation removal and surgical exploration of the fusion site. Biopsy specimens were taken from the fusion mass and evaluated histologically. RESULTS: Radiographic fusion rate was 7 of 9 OP-1 patients and 9 of 10 control patients. Based on surgical exploration of these 16 patients, new bone formation was macroscopically observed in the posterolateral lumbar region in all cases; however, solid fusion was observed in 4 of 7OP-1 and 7 of 9 HA-TCP/autograft patients. Histologic assessment demonstrated viable bone in 6 of 7 OP-1 patients. All the control (HA-TCP/autograft) specimens contained viable bone and fibrous tissue surrounding ceramic granules, suggesting slow incorporation of the graft material. CONCLUSIONS: In a human posterolateral lumbar spine trial, OP-1 reliably induced viable amounts of new bone formation, but the fusion success rate evaluated by surgical exploration was only 4 of 7.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fairbank, J. C. T., & Pynsent, P. B. (2000) · Spine · doi:10.1097/00007632-200011150-00017 · Cited by 5,851
Cited by
Zara, J. N., Siu, R. K., Zhang, X., Shen, J., Ngo, R., Lee, M., Li, W., Chiang, M., Chung, J., Kwak, J., et al. (2011) · Tissue Engineering Part A · doi:10.1089/ten.tea.2010.0555 · Cited by 560
Bessa, P. C., Casal, M., & Reis, R. L. (2008) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.74 · Cited by 549
BONE MORPHOGENETIC PROTEINS IN CLINICAL APPLICATIONS
Gautschi, O. P., Frey, S. P., & Zellweger, R. (2007) · ANZ Journal of Surgery · doi:10.1111/j.1445-2197.2007.04175.x · Cited by 406
Review: Mineralization of Synthetic Polymer Scaffolds for Bone Tissue Engineering
Kretlow, J. D., & Mikos, A. G. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0394 · Cited by 343
Effects of protein dose and delivery system on BMP-mediated bone regeneration
Boerckel, J. D., Kolambkar, Y. M., Dupont, K. M., Uhrig, B. A., Phelps, E. A., Stevens, H. Y., García, A. J., & Guldberg, R. E. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.03.063 · Cited by 323
Psychosocial Aspects of Disabling Musculoskeletal Pain
Vranceanu, A.-M., Barsky, A., & Ring, D. (2009) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.h.01512 · Cited by 304
Clinical applications of BMP-7/OP-1 in fractures, nonunions and spinal fusion
White, A. P., Vaccaro, A. R., Hall, J. A., Whang, P. G., Friel, B. C., & McKee, M. D. (2007) · International Orthopaedics · doi:10.1007/s00264-007-0422-x · Cited by 270
Jeon, O., Song, S. J., Kang, S.-W., Putnam, A. J., & Kim, B.-S. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.02.023 · Cited by 261
Studies of bone morphogenetic protein-based surgical repair
Lo, K. W.-H., Ulery, B. D., Ashe, K. M., & Laurencin, C. T. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.03.014 · Cited by 249
“1% of patients treated with OP-1® to assist posterolateral lumbar fusion actually had complete spinal fusion one year after surgery [23].”
A COMPREHENSIVE REVIEW OF THE SAFETY PROFILE OF BONE MORPHOGENETIC PROTEIN IN SPINE SURGERY
Benglis, D., Wang, M. Y., & Levi, A. D. (2008) · Operative Neurosurgery · doi:10.1227/01.neu.0000326030.24220.d8 · Cited by 232
“Human trials using rhBMP-7 and rhBMP-2 in posterolateral fusion have been reported with and without instrumentation (17, 21, 30, 75).”
MethodScaffold Translation: Barriers Between Concept and Clinic
Hollister, S. J., & Murphy, W. L. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2011.0251 · Cited by 224
Complications Related to Osteobiologics Use in Spine Surgery: A Systematic Review
Mroz, T. E., Wang, J. C., Hashimoto, R., & Norvell, D. C. (2010) · Spine · doi:10.1097/brs.0b013e3181d81ef2 · Cited by 217
Stem Cells from Adipose Tissue Allow Challenging New Concepts for Regenerative Medicine
Helder, M. N., Knippenberg, M., Klein-Nulend, J., & Wuisman, P. I. J. M. (2007) · Tissue Engineering · doi:10.1089/ten.2006.0165 · Cited by 207
Raizman, N. M., OʼBrien, J. R., Poehling-Monaghan, K. L., & Yu, W. D. (2009) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-200908000-00003 · Cited by 194
“However, a study of single-level instrumented fusion followed by surgical exploration and instrumentation removal showed that whereas 7 of 9 patients treated with OP-1 and 9 of 10 patients receiving autograft plus hydroxyapatite and tricalcium phosphate demonstrated radiographic fusion, only 4 of the 7 OP-1 patients a…”
Bone and Joint Research Group, H. D. A. H., Gothard, D., Smith, E., Kanczler, J., Rashidi, H., Qutachi, O., Henstock, J., Rotherham, M., El Haj, A., Shakesheff, K., et al. (2014) · European Cells and Materials · doi:10.22203/ecm.v028a13 · Cited by 188
Haidar, Z. S., Hamdy, R. C., & Tabrizian, M. (2009) · Biotechnology Letters · doi:10.1007/s10529-009-0100-8 · Cited by 179
“…et al. (2002) OP-1 putty* Posterolateral lumbar fusions 36 Vaccaro et al. (2005) OP-1 putty Posterolateral lumbar arthrodesis (instrumented) 19 Kanayama et al. (2006) OP-1 putty Posterolateral lumbar arthrodesis 24 Vaccaro et al. (2008) *OP-1 putty consists of rhOP-1, Type I bovine bone…”
Dawson, E., Bae, H. W., Burkus, J. K., Stambough, J. L., & Glassman, S. D. (2009) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.g.01157 · Cited by 164
Muthu, S., & Ramakrishnan, E. (2021) · Spine · doi:10.1097/brs.0000000000003645 · Cited by 30
Metadata
- Authors
- Kanayama, M., Hashimoto, T., Shigenobu, K., Yamane, S., Bauer, T. W., & Togawa, D.
- Venue
- Spine
- Published
- 2006-05
- Volume
- 31
- Issue
- 10
- Pages
- 1067-1074
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2035935211
- Cited by
- 153
- References
- 1
- FWCI
- 11.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.