Dual-energy X-ray absorptiometry and body composition
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: Dual-energy X-ray absorptiometry is now widely adopted for the measurement of the fat, fat-free soft tissue and bone mineral compartments of the body. Whereas it is regarded by many as a reference technique for such measurements, it is not without limitations. Inter and intra-manufacturer differences have been areas of concern. This review focuses on recent literature addressing these areas and the issue of validity. RECENT FINDINGS: Body composition measurements using newer generation dual-energy X-ray absorptiometry machines compared between different manufacturers and compared with earlier instruments continue to show differences that may be unacceptable, particularly for investigators upgrading their machines or involved in multicentre studies using different machines. In terms of validity, significant deviations at a group level are reported when compared with reference four-component models, and perhaps more importantly, wide limits of agreement are seen that are a concern for the interpretation of results at an individual level. SUMMARY: It is important that investigators recognize the limitations of dual-energy X-ray absorptiometry technology in the interpretation of their results. There is a continuing need both for inter-machine comparisons and validation studies against accepted criterion methods, particularly as new software or technological changes are introduced. Such studies permit the development of translation equations for the cross-calibration of devices, and may be vital for cross-sectional studies. For longitudinal studies in many populations, dual-energy X-ray absorptiometry is without question a valuable technique for the measurement of compositional changes, both at the total body and regional levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Visser, M., Deeg, D. J. H., & Lips, P. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030604 · Cited by 1,099
Total-body skeletal muscle mass: Estimation by a new dual-energy X-ray absorptiometry method
Kim, J., Wang, Z., Heymsfield, S. B., Baumgartner, R. N., & Gallagher, D. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/76.2.378 · Cited by 737
Dual-energy X-ray absorptiometry body composition model: review of physical concepts
Pietrobelli, A., Formica, C., Wang, Z., & Heymsfield, S. B. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.271.6.e941 · Cited by 594
Accuracy of measurements of body composition by dual-energy x-ray absorptiometry in vivo
Svendsen, O., Haarbo, J., Hassager, C., & Christiansen, C. (1993) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/57.5.605 · Cited by 411
Use of dual-energy x-ray absorptiometry in body-composition studies: not yet a “gold standard”
Roubenoff, R., Kehayias, J., Dawson-Hughes, B., & Heymsfield, S. (1993) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/58.5.589 · Cited by 369
Sarcopenia and increased adipose tissue infiltration of muscle in elderly African American women
Song, M.-Y., Ruts, E., Kim, J., Janumala, I., Heymsfield, S., & Gallagher, D. (2004) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/79.5.874 · Cited by 324
Clinical Applications of Body Composition Measurements Using DXA
Albanese, C. V., Diessel, E., & Genant, H. K. (2003) · Journal of Clinical Densitometry · doi:10.1385/jcd:6:2:75 · Cited by 276
Glickman, S. G., Marn, C. S., Supiano, M. A., & Dengel, D. R. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01234.2003 · Cited by 274
Accuracy of dual-energy x-ray absorptiometry for body-composition measurements in children
Ellis, K., Shypailo, R., Pratt, J., & Pond, W. (1994) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/60.5.660 · Cited by 229
Sopher, A. B., Thornton, J. C., Wang, J., Pierson, R. N., Heymsfield, S. B., & Horlick, M. (2004) · Pediatrics · doi:10.1542/peds.113.5.1285 · Cited by 228
Cited by
Assessing Adiposity: A Scientific Statement From the American Heart Association
Cornier, M.-A., Després, J.-P., Davis, N., Grossniklaus, D. A., Klein, S., Lamarche, B., Lopez-Jimenez, F., Rao, G., St-Onge, M.-P., Towfighi, A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318233bc6a · Cited by 945
Sarcopenia: etiology, clinical consequences, intervention, and assessment
Lang, T., Streeper, T., Cawthon, P., Baldwin, K., Taaffe, D. R., & Harris, T. B. (2010) · Osteoporosis International · doi:10.1007/s00198-009-1059-y · Cited by 777
Pitfalls in the measurement of muscle mass: A need for a reference standard
Buckinx, F., Landi, F., Cesari, M., Fielding, R. A., Visser, M., Engelke, K., Maggi, S., Dennison, E., Al‐Daghri, N. M., Allepaerts, S., et al. (2018) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12268 · Cited by 765
“However, this is a highly intensive and costly procedure and does not enable the measurement of muscle mass specifically.(88) As a 3component model (combining protein and minerals into ‘solids’), DXA is superior to standard densitometry (which”
Baracos, V. E., Reiman, T., Mourtzakis, M., Gioulbasanis, I., & Antoun, S. (2010) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2010.28608c · Cited by 482
Simmonds, M., Burch, J., Llewellyn, A., Griffiths, C., Yang, H., Owen, C., Duffy, S., & Woolacott, N. (2015) · Health Technology Assessment · doi:10.3310/hta19430 · Cited by 381
Nana, A., Slater, G. J., Stewart, A. D., & Burke, L. M. (2015) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2013-0228 · Cited by 372
Stroke induced Sarcopenia: Muscle wasting and disability after stroke
Scherbakov, N., von Haehling, S., Anker, S. D., Dirnagl, U., & Doehner, W. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.10.031 · Cited by 295
DXA: Technical aspects and application
Bazzocchi, A., Ponti, F., Albisinni, U., Battista, G., & Guglielmi, G. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.04.004 · Cited by 279
Contemporary methods of body composition measurement
Fosbøl, M. Ø., & Zerahn, B. (2015) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12152 · Cited by 279
Tools in the Assessment of Sarcopenia
Cooper, C., Fielding, R., Visser, M., van Loon, L. J., Rolland, Y., Orwoll, E., Reid, K., Boonen, S., Dere, W., Epstein, S., et al. (2013) · Calcified Tissue International · doi:10.1007/s00223-013-9757-z · Cited by 246
“However, DXA is unable to evaluate intramuscular fat, which can account for 5–15 % of observed muscle mass in obese people [39].”
Guglielmi, G., Ponti, F., Agostini, M., Amadori, M., Battista, G., & Bazzocchi, A. (2016) · Aging Clinical and Experimental Research · doi:10.1007/s40520-016-0589-3 · Cited by 221
“Variations in soft tissue hydration may determine errors in estimation of BC: A DXA fundamental assumption is in fact a ‘‘constancy’’ of fat-free body mass hydration [77, 78], even if small changes (in a range from 68.”
BackgroundCawthon, P. M., Orwoll, E. S., Peters, K. E., Ensrud, K. E., Cauley, J. A., Kado, D. M., Stefanick, M. L., Shikany, J. M., Strotmeyer, E. S., Glynn, N. W., et al. (2019) · The Journals of Gerontology: Series A · doi:10.1093/gerona/gly129 · Cited by 213
“Measures of lean mass from DXA are influenced by hydration status and the presence of extracellular fluid, as water is included in lean mass estimates (as water is neither bone nor fat) (40).”
BackgroundBody composition assessment by dual-energy X-ray absorptiometry (DXA)
Andreoli, A., Scalzo, G., Masala, S., Tarantino, U., & Guglielmi, G. (2009) · La radiologia medica · doi:10.1007/s11547-009-0369-7 · Cited by 202
The cachexia score (CASCO): a new tool for staging cachectic cancer patients
Argilés, J. M., López-Soriano, F. J., Toledo, M., Betancourt, A., Serpe, R., & Busquets, S. (2011) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1007/s13539-011-0027-5 · Cited by 183
“In addition to weight determination, lean body mass can be measured using either bioelectrical impedance analysis (BIA) [14, 15] or dual X-ray absorptiometry (DEXA) [15, 16], although the latter is preferred [17].”
MethodScott, D., Seibel, M., Cumming, R., Naganathan, V., Blyth, F., Le Couteur, D. G., Handelsman, D. J., Waite, L. M., & Hirani, V. (2017) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.3016 · Cited by 174
“Furthermore, although DXA is an accepted technique for assessing body composition and BMD, its assumptions may influence interpretation of results,((31)) so future studies using imaging techniques such as magnetic resonance imaging and computed tomography may shed further light on the effects of sarcopenic obesity on…”
Savastano, S., Belfiore, A., Di Somma, C., Mauriello, C., Rossi, A., Pizza, G., De Rosa, A., Prestieri, G., Angrisani, L., & Colao, A. (2010) · Obesity Surgery · doi:10.1007/s11695-009-0006-5 · Cited by 100
Prediction of Fatness by Standing 8‐Electrode Bioimpedance: A Multiethnic Adolescent Population
Sluyter, J. D., Schaaf, D., Scragg, R. K. R., & Plank, L. D. (2010) · Obesity · doi:10.1038/oby.2009.166 · Cited by 85
“Although DXA, regarded as a gold standard for bone measurement, is not without limitations for body fat estimation (23), it is widely available and more easily applied and acceptable to volunteers than other reference methods such as those based on hydrodensitometry or isotope dilution.”
MethodSelf-citationRush, E. C., Chandu, V, & Plank, L. D. (2006) · International Journal of Obesity · doi:10.1038/sj.ijo.0803230 · Cited by 64
Self-citationRocha, J. N. D. S., Pereira-Monteiro, M. R., Vasconcelos, A. B. S., Pantoja-Cardoso, A., Aragão-Santos, J. C., & Da Silva-Grigoletto, M. E. (2024) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2023.105303 · Cited by 15
Metadata
- Authors
- Plank, L. D.
- Venue
- Current Opinion in Clinical Nutrition & Metabolic Care
- Published
- 2005-05
- Volume
- 8
- Issue
- 3
- Pages
- 305-309
- ISSN
- 1363-1950 (ISSN-L)
- OpenAlex
- W2010239915
- Cited by
- 185
- References
- 48
- FWCI
- 2.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.