Limitations and validation of bioelectrical impedance analysis in morbidly obese patients
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: Several factors limit the use of bioelectrical impedance analysis as a valid predictor of the amount of body fat in morbidly obese individuals. The purpose of this review is to examine the theory and assumptions that may limit the use of bioelectrical impedance analysis in such individuals. RECENT FINDINGS: There is currently insufficient validation of bioelectrical impedance analysis equations in obese individuals with body mass indices greater than 34 kg/m. Several factors limit the application of bioelectrical impedance analysis in morbidly obese individuals. Obese individuals have a relatively high amount of extracellular water and total body water, which may overestimate fat-free mass and underestimate fat mass. Central body fat will generally overestimate the percentage of fat-free mass and underestimate the percentage of fat mass in overweight and obese adults with the use of prediction formulas developed in normal weight individuals. SUMMARY: A relatively increased amount of total body water and a relative increase in extracellular water will result in an underestimation of the percentage of body fat and an overestimation of fat-free mass in the morbid obesity state. A different body build disposition (mainly in those with severe abdominal obesity) will result in an overestimation of the percentage of body fat. New equations are needed to validate bioelectrical impedance analysis in morbidly obese patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Das, S. K., Roberts, S. B., Kehayias, J. J., Wang, J., Hsu, L. K. G., Shikora, S. A., Saltzman, E., & McCrory, M. A. (2003) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00185.2002 · Cited by 183
Eisenkölbl, J., Kartasurya, M., & Widhalm, K. (2001) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1601184 · Cited by 115
Cited by
Norman, K., Stobäus, N., Pirlich, M., & Bosy-Westphal, A. (2012) · Clinical Nutrition · doi:10.1016/j.clnu.2012.05.008 · Cited by 1,049
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
“[16,59,60], is through the use of quad current injection electrodes located on the right and left wrist and foot, and quad voltage electrodes located at the same place (Figure 4d).”
BackgroundLean Tissue Imaging: A New Era for Nutritional Assessment and Intervention
Prado, C. M. M., & Heymsfield, S. B. (2014) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607114550189 · Cited by 550
Is bioelectrical impedance accurate for use in large epidemiological studies?
Dehghan, M., & Merchant, A. T. (2008) · Nutrition Journal · doi:10.1186/1475-2891-7-26 · Cited by 505
Bioimpedance Spectroscopy for Clinical Assessment of Fluid Distribution and Body Cell Mass
Earthman, C., Traughber, D., Dobratz, J., & Howell, W. (2007) · Nutrition in Clinical Practice · doi:10.1177/0115426507022004389 · Cited by 209
Kasper, A. M., Langan-Evans, C., Hudson, J. F., Brownlee, T. E., Harper, L. D., Naughton, R. J., Morton, J. P., & Close, G. L. (2021) · Nutrients · doi:10.3390/nu13041075 · Cited by 196
“Nevertheless, this method has several limitations including (1) outputs that can be affected by temperature and hydration status [28]; (2) sensitivity to conductive surface of electrodes and electrode placement [29]; (3) makes assumptions on the composition of the body in formula and calculations, irrespective of popu…”
MethodMeasuring Muscle Mass and Strength in Obesity: a Review of Various Methods
Sizoo, D., de Heide, L. J. M., Emous, M., van Zutphen, T., Navis, G., & van Beek, A. P. (2021) · Obesity Surgery · doi:10.1007/s11695-020-05082-2 · Cited by 77
Gil, S., Kirwan, J. P., Murai, I. H., Dantas, W. S., Merege‐Filho, C. A. A., Ghosh, S., Shinjo, S. K., Pereira, R. M. R., Teodoro, W. R., Felau, S. M., et al. (2021) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12815 · Cited by 72
Ito, M. K., Gonçalves, V. S. S., Faria, S. L. C. M., Moizé, V., Porporatti, A. L., Guerra, E. N. S., De Luca Canto, G., & de Carvalho, K. M. B. (2017) · Obesity Surgery · doi:10.1007/s11695-016-2453-0 · Cited by 69
Kreidieh, D., Itani, L., El Masri, D., Tannir, H., Citarella, R., & El Ghoch, M. (2018) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd5040051 · Cited by 46
“Second, we assessed body composition using an impedance analyser; despite being validated, this method has not yet been accepted as a gold-standard technique for overweight and obese patients [18], especially in terms of lean body mass assessment and regional pattern measurements.”
MethodJiménez, A., Omaña, W., Flores, L., Coves, M. J., Bellido, D., Perea, V., & Vidal, J. (2012) · Obesity Surgery · doi:10.1007/s11695-011-0570-3 · Cited by 40
Sylivris, A., Mesinovic, J., Scott, D., & Jansons, P. (2022) · Obesity Reviews · doi:10.1111/obr.13442 · Cited by 39
Kreidieh, D., Itani, L., El Masri, D., Tannir, H., & El Ghoch, M. (2020) · Frontiers in Endocrinology · doi:10.3389/fendo.2020.00022 · Cited by 21
Metadata
- Authors
- Coppini, L. Z., Waitzberg, D. L., & Campos, A. C. L.
- Venue
- Current Opinion in Clinical Nutrition & Metabolic Care
- Published
- 2005-05
- Volume
- 8
- Issue
- 3
- Pages
- 329-332
- ISSN
- 1363-1950 (ISSN-L)
- OpenAlex
- W2056594824
- Cited by
- 199
- References
- 2
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.