CoChat

Visual Acuity and Optical Parameters in Progressive-Power Lenses

VILLEGAS, ELOY A., ARTAL, PABLO · 2006 · Optometry and Vision Science
Cited by 48

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

PURPOSES: The purposes of this study are to explore the effect of astigmatism and high-order aberrations of progressive-power lenses (PPLs) on visual acuity (VA) and to find a good optical metric for evaluating visual performance of PPLs. METHODS: A Hartmann-Shack (HS) wavefront sensor was used to measure PPLs and human eyes either independently or in combination. An additional channel permits the measurement of VA under the same optical conditions. Measurements were taken in six relevant locations of a PPL and in three eyes of different normal subjects. In every case, we obtained the wavefront aberration as Zernike polynomials expansions, the root mean square (RMS) error, and two metrics on point spread function (PSF): Strehl ratio and the common logarithm of the volume under the PSF normalized to one (Log_Vol_PSF). RESULTS: Aberration coupling of the PPL with the eye tends to equalize the retinal image quality between central and peripheral zones of the progressive lenses. In the corridor of the PPL, the combination of small amounts of coma, trefoil, and astigmatism (total RMS 0.1 mum) does not significantly affect VA. The continuous increase of astigmatism from corridor to outside zones reduces moderately the quality of vision. The highest correlations between optical metrics and VA were found for Log_Vol_PSF of the entire system eye plus PPL. CONCLUSIONS: Ocular aberrations reduce optical quality difference between corridor and peripheral zones of PPLs. In the same way, VA through the corridor is similar to that of eyes without a lens and it decreases slowly toward peripheral locations. VA through PPLs is well predicted by the logarithm of metrics directly related with image spread (Log_Vol_PSF or equivalent) of the complete system of the eye with the lens.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/01.opx.0000232818.37832.ee

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 49

  1. Sullivan CM, 1989, Grating visual acuity testing as a means of psychophysical assessment of progressive addition lenses, Optom Vis Sci, 66, 565, 10.1097/00006324-198909000-00001 · doi:10.1097/00006324-198909000-00001
  2. Kris MJ, 1999, Practitioner trial of SOLA Percepta progressive lenses, Clin Exp Optom, 82, 187, 10.1111/j.1444-0938.1999.tb06641.x · doi:10.1111/j.1444-0938.1999.tb06641.x
  3. Boroyan HJ, 1995, Lined multifocal wearers prefer progressive addition lenses, J Am Optom Assoc, 66, 296
  4. Sullivan CM, 1989, Analysis of a progressive addition lens population, Ophthal Physiol Opt, 9, 163, 10.1111/j.1475-1313.1989.tb00837.x · DOI
  5. Fauquier C, 1995, Vision Science and Its Applications, OSA Technical Digest Series, 151
  6. Sullivan CM, 1988, Progressive addition and variable focus lenses: a review, Ophthal Physiol Opt, 8, 402, 10.1111/j.1475-1313.1988.tb01177.x · doi:10.1111/j.1475-1313.1988.tb01177.x
  7. Legge GE, 1987, Tolerance to visual defocus, J Opt Soc Am (A), 4, 851, 10.1364/JOSAA.4.000851 · doi:10.1364/josaa.4.000851
  8. Campbell FW, 1965, Optical and retinal factors affecting visual resolution, J Physiol (Lond), 181, 576, 10.1113/jphysiol.1965.sp007784 · DOI · Paper page
  9. Woods RL, 1996, Monocular diplopia caused by ocular aberrations and hyperopic defocus, Vision Res, 36, 3597, 10.1016/0042-6989(96)00092-2 · doi:10.1016/0042-6989(96)00092-2
  10. Charman WN, 1976, The optical quality of the monochromatic retinal image as a function of focus, Br J Physiol Opt, 31, 119
  11. Miller AD, 1997, Effect of small focal errors on vision, Optom Vis Sci, 74, 521, 10.1097/00006324-199707000-00020 · doi:10.1097/00006324-199707000-00020
  12. Artal P, 1995, Through focus image quality of eyes implanted with monofocal and multifocal intraocular lenses, Opt Eng, 34, 772, 10.1117/12.191818 · doi:10.1117/12.191818
  13. Villegas EA, 2002, Correlation between optical and psychophysical parameters as a function of defocus, Optom Vis Sci, 79, 60
  14. Campbell FW, 1957, The depth of field of the human eye, Opt Acta, 4, 157, 10.1080/713826091 · DOI
  15. Tucker J, 1975, The depth‐of‐focus of the human eye for Snellen letters, Am J Optom Physiol Opt, 52, 3, 10.1097/00006324-197501000-00002 · DOI · Paper page
  16. Atchison DA, 1997, Subjective depth‐of‐focus of the eye, Optom Vis Sci, 74, 511, 10.1097/00006324-199707000-00019 · DOI
  17. Marcos S, 1999, The depth‐of‐field of the human eye from objective and subjective measurements, Vision Res, 39, 2039, 10.1016/S0042-6989(98)00317-4 · DOI
  18. Mouroulis P, 1992, Visual instrument image quality metrics and the effects of coma and astigmatism, J Opt Soc Am (A), 9, 34, 10.1364/JOSAA.9.000034 · DOI
  19. Minkwitz G, 1963, [On the surface astigmatism of a fixed symmetrical aspheric surface.], Opt Acta (Lond), 10, 223
  20. Volk D, 1962, The omnifocal lens for presbyopia, Arch Ophthalmol, 68, 776, 10.1001/archopht.1962.00960030780012 · doi:10.1001/archopht.1962.00960030780012
  21. Boudoncle B, 1990, Proceedings of the International Lens Design Conference, Monterey, CA, June 11–14, 1990, 194
  22. Fowler CW, 1989, A comparison of three methods for the measurement of progressive addition lenses, Ophthal Physiol Opt, 9, 81, 10.1111/j.1475-1313.1989.tb00813.x · DOI
  23. Spiers T, 2000, Optical Fourier filtering for whole lens assessment of progressive power lenses, Ophthal Physiol Opt, 20, 281, 10.1046/j.1475-1313.2000.00541.x · doi:10.1046/j.1475-1313.2000.00541.x
  24. Burns D, 1995, Blur due to pupil area when using progressive addition spectacles, Ophthal Physiol Opt, 15, 273, 10.1046/j.1475-1313.1995.9500010b.x · DOI
  25. Maitenaz B, 1967, Image retienne donnée par une verre correcteur de puissance progressive, Revue d'Optique, 46, 233
  26. Villegas EA, 2003, Spatially resolved wavefront aberrations of ophthalmic progressive‐power lenses in normal viewing conditions, Optom Vis Sci, 80, 106, 10.1097/00006324-200302000-00006 · doi:10.1097/00006324-200302000-00006 · Paper page
  27. Liang J, 1994, Objective measurement of wave aberrations of the human eye with the use of a Hartmann‐Shack wave‐front sensor, J Opt Soc Am (A), 11, 1949, 10.1364/JOSAA.11.001949 · DOI · Paper page
  28. Liang J, 1997, Aberrations and retinal image quality of the normal human eye, J Opt Soc Am (A), 14, 2873, 10.1364/JOSAA.14.002873 · DOI · Paper page
  29. Prieto PM, 2000, Analysis of the performance of the Hartmann‐Shack sensor in the human eye, J Opt Soc Am (A), 17, 1388, 10.1364/JOSAA.17.001388 · DOI · Paper page
  30. 1993, Standard for the Safe Use of Lasers: ANSI Z136.1
  31. Thibos LN, 2000, Vision Science and Its Applications, OSA Trends in Optics and Photonics Series, 232
  32. Chateau N, 1996, Infrared pupillometry in presbyopes fitted with soft contact lenses, Optom Vis Sci, 73, 733, 10.1097/00006324-199612000-00003 · DOI
  33. BlendowskeR VillegasEA ArtalP.An analytical model describing aberrations in the progression corridor of progressive addition lenses. Optom Vis Sci (in press).
  34. Guirao A, 1999, Average optical performance of the human eye as a function of age in a normal population, Invest Ophthalmol Vis Sci, 40, 203
  35. Artal P, 2002, Contribution of the cornea and internal surfaces to the change of ocular aberrations with age, J Opt Soc Am (A), 19, 137, 10.1364/JOSAA.19.000137 · DOI · Paper page
  36. I Jspeert JK, 1990, The intraocular straylight function in 129 healthy volunteers; dependence on angle, age and pigmentation, Vision Res, 30, 699, 10.1016/0042-6989(90)90096-4 · DOI · Paper page
  37. Villegas EA, 2006, The effect of correcting small astigmatisms on visual acuity, Invest Ophthalmol Vis Sci, 47
  38. Atchison DA, 2005, Noticeable, troublesome and objectionable limits of blur, Vision Res, 45, 1967, 10.1016/j.visres.2005.01.022 · DOI
  39. Ciuffreda KJ, 2006, ‘Bothersome blur': a functional unit of blur perception, Vision Res, 46, 895, 10.1016/j.visres.2005.10.004 · DOI
  40. Applegate RA, 2003, Visual acuity as a function of Zernike mode and level of root mean square error, Optom Vis Sci, 80, 97, 10.1097/00006324-200302000-00005 · doi:10.1097/00006324-200302000-00005 · Paper page
  41. Fernandez EJ, 2002, Adaptive optics visual simulator, J Refract Surg, 18, S634, 10.3928/1081-597X-20020901-27 · DOI
  42. Artal P, 2004, Neural compensation for the eye's optical aberrations, J Vis, 4, 281, 10.1167/4.4.4 · DOI · Paper page
  43. Villegas EA, 2005, Is there neural adaptation to the aberrations in progressive power lenses, Invest Ophthalmol Vis Sci, 46
  44. Plainis S, 2005, The effect of ocular aberrations on steady‐state errors of accommodative response, J Vis, 5, 466, 10.1167/5.5.7 · DOI · Paper page
  45. Buehren T, 2006, Accommodation stimulus‐response function and retinal image quality, Vision Res, 46, 1633, 10.1016/j.visres.2005.06.009 · DOI
  46. Cheng H, 2004, A population study on changes in wave aberrations with accommodation, J Vis, 4, 272, 10.1167/4.4.3 · DOI
  47. Artal P, 2002, Are optical aberrations during accommodation a significant problem for refractive surgery, J Refract Surg, 18, S563, 10.3928/1081-597X-20020901-13 · doi:10.3928/1081-597x-20020901-13
  48. He JC, 2003, Change in corneal shape and corneal wave‐front aberrations with accommodation, J Vis, 3, 456
  49. Thibos LN, 2004, Accuracy and precision of objective refraction from wavefront aberrations, J Vis, 4, 329, 10.1167/4.4.9 · DOI · Paper page

Cited by

See all 48

Metadata

Authors
VILLEGAS, E. A., & ARTAL, P.
Venue
Optometry and Vision Science
Publisher
Wiley
Published
2006-09
Volume
83
Issue
9
Pages
672-681
ISSN
1040-5488 (ISSN-L)
OpenAlex
W2113650777
Cited by
48
References
3
FWCI
1.33
Type
journal article
Language
en
Open access
closed
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.