Perioperative Auto-titrated Continuous Positive Airway Pressure Treatment in Surgical Patients with Obstructive Sleep Apnea: A Randomized Controlled Trial

Liao, Pu, Luo, Quanwei, Elsaid, Hisham, Kang, Weimin, Shapiro, Colin M., Chung, Frances · 2013 · Anesthesiology
Cited by 112

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Background: Obstructive sleep apnea (OSA) may worsen postoperatively. The objective of this randomized open-label trial is to determine whether perioperative auto-titrated continuous positive airway pressure (APAP) treatment decreases postoperative apnea hypopnea index (AHI) and improves oxygenation in patients with moderate and severe OSA. Methods: The consented patients with AHI of more than 15 events/h on preoperative polysomnography were randomized into the APAP or control group (receiving routine care). The APAP patients received APAP for 2 or 3 preoperative, and 5 postoperative nights. All patients were monitored with oximetry for 7 to 8 nights (N) and underwent polysomnography on postoperative N3. The primary outcome was AHI on the postoperative N3. Results: One hundred seventy-seven OSA patients undergoing orthopedic and other surgeries were enrolled (APAP: 87 and control: 90). There was no difference between the two groups in baseline data. One hundred six patients (APAP: 40 and control: 66) did polysomnography on postoperative N3, and 100 patients (APAP: 39 and control: 61) completed the study. The compliance rate of APAP was 45%. The APAP usage was 2.4–4.6 h/night. In the APAP group, AHI decreased from preoperative baseline: 30.1 (22.1, 42.5) events/h (median [25th, 75th percentile]) to 3.0 (1.0, 12.5) events/h on postoperative N3 (P < 0.001), whereas, in the control group, AHI increased from 30.4 (23.2, 41.9) events/h to 31.9 (13.5, 50.2) events/h, P = 0.302. No significant change occurred in the central apnea index. Conclusions: The trial showed the feasibility of perioperative APAP for OSA patients. Perioperative APAP treatment significantly reduced postoperative AHI and improved oxygen saturation in the patients with moderate and severe OSA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aln.0b013e318297d89a

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 112

Metadata

Authors
Liao, P., Luo, Q., Elsaid, H., Kang, W., Shapiro, C. M., & Chung, F.
Venue
Anesthesiology
Published
2013-10
Volume
119
Issue
4
Pages
837-847
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2000726520
Cited by
112
References
11
FWCI
7.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Perioperative Auto-titrated Continuous Positive Airway Pressure Treatment in Surgical Patients with Obstructive Sleep Apnea: A Randomized Controlled Trial. https://app.cochat.ai/papers/10.1097/aln.0b013e318297d89a
The paper
Liao, P., Luo, Q., Elsaid, H., Kang, W., Shapiro, C. M., & Chung, F. (2013). Perioperative Auto-titrated Continuous Positive Airway Pressure Treatment in Surgical Patients with Obstructive Sleep Apnea: A Randomized Controlled Trial. Anesthesiology. https://doi.org/10.1097/aln.0b013e318297d89a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.