Predicting Fluid Responsiveness by Passive Leg Raising: A Systematic Review and Meta-Analysis of 23 Clinical Trials*
Open accessThe DOI matches its Crossref record, with a small difference in title or year; 75 of the 75 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Passive leg raising creates a reversible increase in venous return allowing for the prediction of fluid responsiveness. However, the amount of venous return may vary in various clinical settings potentially affecting the diagnostic performance of passive leg raising. Therefore we performed a systematic meta-analysis determining the diagnostic performance of passive leg raising in different clinical settings with exploration of patient characteristics, measurement techniques, and outcome variables. DATA SOURCES: PubMed, EMBASE, the Cochrane Database of Systematic Reviews, and citation tracking of relevant articles. STUDY SELECTION: Clinical trials were selected when passive leg raising was performed in combination with a fluid challenge as gold standard to define fluid responders and non-responders. DATA EXTRACTION: Trials were included if data were reported allowing the extraction of sensitivity, specificity, and area under the receiver operating characteristic curve. DATA SYNTHESIS: Twenty-three studies with a total of 1,013 patients and 1,034 fluid challenges were included. The analysis demonstrated a pooled sensitivity of 86% (95% CI, 79-92), pooled specificity of 92% (95% CI, 88-96), and a summary area under the receiver operating characteristic curve of 0.95 (95% CI, 0.92-0.98). Mode of ventilation, type of fluid used, passive leg raising starting position, and measurement technique did not affect the diagnostic performance of passive leg raising. The use of changes in pulse pressure on passive leg raising showed a lower diagnostic performance when compared with passive leg raising-induced changes in flow variables, such as cardiac output or its direct derivatives (sensitivity of 58% [95% CI, 44-70] and specificity of 83% [95% CI, 68-92] vs sensitivity of 85% [95% CI, 78-90] and specificity of 92% [95% CI, 87-94], respectively; p < 0.001). CONCLUSIONS: Passive leg raising retains a high diagnostic performance in various clinical settings and patient groups. The predictive value of a change in pulse pressure on passive leg raising is inferior to a passive leg raising-induced change in a flow variable.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Self-citationEarly goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743
Comparison of Two Fluid-Management Strategies in Acute Lung Injury
(2006) · New England Journal of Medicine · doi:10.1056/nejmoa062200 · Cited by 3,538
Deeks, J. J., Macaskill, P., & Irwig, L. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.01.016 · Cited by 2,910 · cited 2×
“Brun (48) 23 28 0 (0) 0 (0) 17 (74) — 87 101 6.”
BackgroundBoyd, J. H., Forbes, J., Nakada, T.-A., Walley, K. R., & Russell, J. A. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181feeb15 · Cited by 1,517
A hierarchical regression approach to meta‐analysis of diagnostic test accuracy evaluations
Rutter, C. M., & Gatsonis, C. A. (2001) · Statistics in Medicine · doi:10.1002/sim.942 · Cited by 1,505
Predicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
Passive leg raising predicts fluid responsiveness in the critically ill*
Monnet, X., Rienzo, M., Osman, D., Anguel, N., Richard, C., Pinsky, M. R., & Teboul, J.-L. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000215453.11735.06 · Cited by 952
Marik, P. E., & Cavallazzi, R. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a25fd · Cited by 866 · cited 2×
“Monnet (43) 39 — — 28 (72) 25 (64) 39 (100) 93 ± 24 73 ± 18 6.”
ResultEffect of Intraoperative Fluid Management on Outcome after Intraabdominal Surgery
Nisanevich, V., Felsenstein, I., Almogy, G., Weissman, C., Einav, S., & Matot, I. (2005) · Anesthesiology · doi:10.1097/00000542-200507000-00008 · Cited by 864
Pulse pressure variations to predict fluid responsiveness: influence of tidal volume
De Backer, D., Heenen, S., Piagnerelli, M., Koch, M., & Vincent, J.-L. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2586-4 · Cited by 706
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Self-citationvan Enst, W. A., Ochodo, E., Scholten, R. J., Hooft, L., & Leeflang, M. M. (2014) · BMC Medical Research Methodology · doi:10.1186/1471-2288-14-70 · Cited by 429
Self-citationPassive leg raising: five rules, not a drop of fluid!
Monnet, X., & Teboul, J.-L. (2015) · Critical Care · doi:10.1186/s13054-014-0708-5 · Cited by 425
Lamia, B., Ochagavia, A., Monnet, X., Chemla, D., Richard, C., & Teboul, J.-L. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0646-7 · Cited by 393
Derichard, A., Robin, E., Tavernier, B., Costecalde, M., Fleyfel, M., Onimus, J., Lebuffe, G., Chambón, J. P., & Vallet, B. (2009) · British Journal of Anaesthesia · doi:10.1093/bja/aep267 · Cited by 393
Cavallaro, F., Sandroni, C., Marano, C., La Torre, G., Mannocci, A., De Waure, C., Bello, G., Maviglia, R., & Antonelli, M. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1929-y · Cited by 386
Boulain, T., Achard, J.-M., Teboul, J.-L., Richard, C., Perrotin, D., & Ginies, G. (2002) · Chest · doi:10.1378/chest.121.4.1245 · Cited by 351
‘Liberal’ vs. ‘restrictive’ perioperative fluid therapy – a critical assessment of the evidence
BUNDGAARD‐NIELSEN, M., SECHER, N. H., & KEHLET, H. (2009) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2009.02029.x · Cited by 336
Monnet, X., Osman, D., Ridel, C., Lamia, B., Richard, C., & Teboul, J.-L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181968fe1 · Cited by 301
Diagnosis of central hypovolemia by using passive leg raising
Maizel, J., Airapetian, N., Lorne, E., Tribouilloy, C., Massy, Z., & Slama, M. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0642-y · Cited by 297
Passive leg raising for predicting fluid responsiveness: importance of the postural change
Jabot, J., Teboul, J.-L., Richard, C., & Monnet, X. (2009) · Intensive Care Medicine · doi:10.1007/s00134-008-1293-3 · Cited by 289
Hofer, C. K., Müller, S. M., Furrer, L., Klaghofer, R., Genoni, M., & Zollinger, A. (2005) · Chest · doi:10.1378/chest.128.2.848 · Cited by 279
Reuter, D. A., Bayerlein, J., Goepfert, M. S. G., Weis, F. C., Kilger, E., Lamm, P., & Goetz, A. E. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1649-7 · Cited by 265
Holte, K., Klarskov, B., Christensen, D. S., Lund, C., Nielsen, K. G., Bie, P., & Kehlet, H. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000143269.96649.3b · Cited by 262
Monnet, X., Bleibtreu, A., Ferré, A., Dres, M., Gharbi, R., Richard, C., & Teboul, J.-L. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31822f08d7 · Cited by 246
Marik, P. E., Levitov, A., Young, A., & Andrews, L. (2013) · Chest · doi:10.1378/chest.12-1274 · Cited by 243
Holte, K., & Kehlet, H. (2006) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2006.01.003 · Cited by 229
Préau, S., Saulnier, F., Dewavrin, F., Durocher, A., & Chagnon, J.-L. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181c8fe7a · Cited by 224
Monnet, X., Jabot, J., Maizel, J., Richard, C., & Teboul, J.-L. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e318206d2a3 · Cited by 185
Mahjoub, Y., Touzeau, J., Airapetian, N., Lorne, E., Hijazi, M., Zogheib, E., Tinturier, F., Slama, M., & Dupont, H. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181eb3c21 · Cited by 184
Lafanechère, A., Pène, F., Goulenok, C., Delahaye, A., Mallet, V, Choukroun, G., Chiche, J., Mira, J., & Cariou, A. (2006) · Critical Care · doi:10.1186/cc5044 · Cited by 178
Rutlen, D. L., Wackers, F. J., & Zaret, B. L. (1981) · Circulation · doi:10.1161/01.cir.64.1.146 · Cited by 167
Monnet, X., Bataille, A., Magalhaes, E., Barrois, J., Le Corre, M., Gosset, C., Guerin, L., Richard, C., & Teboul, J.-L. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2693-y · Cited by 159
Thiel, S. W., Kollef, M. H., & Isakow, W. (2009) · Critical Care · doi:10.1186/cc7955 · Cited by 150
Biais, M., Vidil, L., Sarrabay, P., Cottenceau, V., Revel, P., & Sztark, F. (2009) · Critical Care · doi:10.1186/cc8195 · Cited by 149
Biais, M., Bernard, O., Ha, J. C., Degryse, C., & Sztark, F. (2010) · British Journal of Anaesthesia · doi:10.1093/bja/aeq031 · Cited by 141
Monnet, X., Dres, M., Ferré, A., Teuff, G. L., Jozwiak, M., Bleibtreu, A., Deley, M. L., Chemla, D., Richard, C., & Teboul, J. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes182 · Cited by 132
Effects of fluid administration on arterial load in septic shock patients
García, M. I. M., González, P. G., Romero, M. Á. G., Cano, A. G., Oscier, C., Rhodes, A., Grounds, R. M., & Cecconi, M. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3898-7 · Cited by 126
Fluid responsiveness predicted by noninvasive Bioreactance-based passive leg raise test
Benomar, B., Ouattara, A., Estagnasié, P., Brusset, A., & Squara, P. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1990-6 · Cited by 125
Kupersztych-Hagege, E., Teboul, J., Artigas, A., Talbot, A., Sabatier, C., Richard, C., & Monnet, X. (2013) · British Journal of Anaesthesia · doi:10.1093/bja/aet282 · Cited by 117
Pre-ejection period variations predict the fluid responsiveness of septic ventilated patients
Feissel, M., Badie, J. C., Merlani, P. G., Faller, J.-P., & Bendjelid, K. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000186415.43713.2f · Cited by 108
García, M. I. M., Cano, A. G., Romero, M. Á. G., Pintado, R. M., Madueño, V. P., & Monrové, J. C. D. (2012) · Annals of Intensive Care · doi:10.1186/2110-5820-2-9 · Cited by 107
Trof, R. J., Sukul, S. P., Twisk, J. W. R., Girbes, A. R. J., & Groeneveld, A. B. J. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1776-x · Cited by 104
Self-citationPassive Leg Raising Does Not Produce a Significant or Sustained Autotransfusion Effect
Gaffney, F. A., Bastian, B. C., Thal, E. R., Atkins, J. M., & Blomqvist, C. G. (1982) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-198203000-00003 · Cited by 97
Prediction of fluid responsiveness in severe preeclamptic patients with oliguria
Brun, C., Zieleskiewicz, L., Textoris, J., Müller, L., Bellefleur, J., Antonini, F., Tourret, M., Ortega, D., Vellin, A., Lefrant, J., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2770-2 · Cited by 91
Lakhal, K., Ehrmann, S., Runge, I., Benzékri-Lefèvre, D., Legras, A., Dequin, P. F., Mercier, E., Wolff, M., Regnier, B., & Boulain, T. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1755-2 · Cited by 89
Basic concepts of fluid responsiveness
Cherpanath, T. G. V., Geerts, B. F., Lagrand, W. K., Schultz, M. J., & Groeneveld, A. B. J. (2013) · Netherlands Heart Journal · doi:10.1007/s12471-013-0487-7 · Cited by 89
Self-citationSuehiro, K., & Okutani, R. (2010) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2010.03.014 · Cited by 86
Changes in cardiac output after acute blood loss and position change in man
WONG, D. H., O'Connor, D. T., Tremper, K. K., Zaccari, J., THOMPSON, P., & Hill, D. W. (1989) · Critical Care Medicine · doi:10.1097/00003246-198910000-00002 · Cited by 78
Geerts, B. F., van den Bergh, L., Stijnen, T., Aarts, L. P. H. J., & Jansen, J. R. C. (2012) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2012.06.003 · Cited by 73
Self-citationGarcía, M. I. M., Cano, A. G., & Monrové, J. C. D. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1295-1 · Cited by 71
Hemodynamic effects of passive leg raising: an echocardiographic study in patients with shock
Caille, V., Jabot, J., Belliard, G., Charron, C., Jardin, F., & Vieillard‐Baron, A. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1067-y · Cited by 68
Change in stroke volume in response to fluid challenge: assessment using esophageal Doppler
Roeck, M., Jakob, S. M., Böhlen, T., Brander, L., Knuesel, R., & Takala, J. A. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1720-4 · Cited by 61
THE CIRCULATORY RESPONSE TO A STANDARD POSTURAL CHANGE IN ISCHAeMIC HEART DISEASE
Thomas, M., & Shillingford, J. P. (1965) · Heart · doi:10.1136/hrt.27.1.17 · Cited by 57
Lukito, V., Djer, M. M., Pudjiadi, A. H., & Munasir, Z. (2011) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e3182388ab3 · Cited by 56
Prediction of fluid responsiveness in patients admitted to the medical intensive care unit
Saugel, B., Kirsche, S. V., Hapfelmeier, A., Phillip, V., Schultheiß, C., Schmid, R. M., & Huber, W. (2012) · Journal of Critical Care · doi:10.1016/j.jcrc.2012.10.008 · Cited by 55
Grassi, G. M., Giannattasio, C., Saino, A. T., Sabadini, E., Capozi, A., Sampieri, L., Cuspidi, C., & Mancia, G. (1988) · Hypertension · doi:10.1161/01.hyp.11.1.92 · Cited by 54
Guinot, P., Zogheib, E. H., Detave, M., Moubarak, M., Hubert, V., Badoux, L., Bernard, E., Besserve, P., Caus, T., & Dupont, H. (2011) · Critical Care · doi:10.1186/cc10451 · Cited by 54
Malbrain, M. L. N. G., & Reuter, D. A. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181f1b6a2 · Cited by 52
Volume Responsiveness in Critically Ill Patients: Use of Sonography to Guide Management
Evans, D. P., Ferraioli, G., Snellings, J. E., & Levitov, A. B. (2014) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.33.1.3 · Cited by 43
Duus, N., Shogilev, D. J., Skibsted, S., Zijlstra, H. W., Fish, E., Oren-Grinberg, A., Lior, Y., Novack, V., Talmor, D. S., Kirkegaard, H., et al. (2014) · Journal of Critical Care · doi:10.1016/j.jcrc.2014.07.031 · Cited by 41
Godfrey, G. E. P., Dubrey, S. W., & Handy, J. M. (2014) · Anaesthesia · doi:10.1111/anae.12560 · Cited by 36
Bedside assessment of passive leg raising effects on venous return
Keller, G., Desebbe, O., Benard, M., Bouchet, J.-B., & Lehot, J.-J. (2011) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-011-9303-3 · Cited by 35
Defining Fluid Responsiveness: A Guide to Patient-Tailored Volume Titration
Cherpanath, T. G. V., Aarts, L. P. H. J., Groeneveld, J., & Geerts, B. F. (2014) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2013.12.025 · Cited by 35
Self-citationPulse Contour Analysis to Assess Hemodynamic Response to Passive Leg Raising
Geerts, B. F., de Wilde, R. B. P., Aarts, L. P. H. J., & Jansen, J. R. C. (2010) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2010.09.013 · Cited by 34
Self-citationPassive leg raising as an indicator of fluid responsiveness in patients with severe sepsis
Dong, Z., Fang, Q., Zheng, X., & Shi, H. (2012) · World Journal of Emergency Medicine · doi:10.5847/wjem.j.issn.1920-8642.2012.03.006 · Cited by 31
Yazigi, A. G., Chouery, É., Hlais, S., Madi‐Jebara, S., Haddad, F., Hayek, G., & Jabbour, K. (2011) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2011.09.014 · Cited by 27
Fellahi, J.-L., Fischer, M.-O., Dalbera, A., Massetti, M., Gérard, J., & Hanouz, J. (2012) · Annals of Intensive Care · doi:10.1186/2110-5820-2-26 · Cited by 26
Yu, T., Huang, Y., Guo, F., Yang, Y., Teboul, J., & Qiu, H. (2013) · Journal of Surgical Research · doi:10.1016/j.jss.2013.07.006 · Cited by 22
Iwashima, Y., Horio, T., Suzuki, Y., Takagi, T., Kamide, K., Ohishi, M., Ogihara, T., Yoshikawa, J., Kawano, Y., & Rakugi, H. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e32833f387c · Cited by 9
Cherpanath, T. G. V., Smeding, L. S., Lagrand, W. K., Hirsch, A., Schultz, M. J., & Groeneveld, J. (2013) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/1440-1681.12187 · Cited by 7
Self-citationHuang, L., Zhang, W., Cai, W.-X., Luo, H., Chen, Y., & Zhang, S. (2010) · Zhonghua jizhen yixue zazhi · doi:10.3760/cma.j.issn.1671-0282.2010.09.004 · Cited by 3
Research works printed but not linked: 2
- Lei, 2010, Chin J Emerg Med, 19, 916
- Perel, 2012, Cochrane Database Syst Rev, 6, CD000567
Cited by
Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021
Evans, L., Rhodes, A., Alhazzani, W., Antonelli, M., Coopersmith, C. M., French, C., Machado, F. R., Mcintyre, L., Ostermann, M., Prescott, H. C., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06506-y · Cited by 5,082
Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock 2021.
Evans, L., Rhodes, A., Alhazzani, W., Antonelli, M., Coopersmith, C. M., French, C., Machado, F. R., Mcintyre, L., Ostermann, M., Prescott, H. C., et al. (2021) · Critical Care Medicine · doi:10.1097/ccm.0000000000005337 · Cited by 2,935
Prediction of fluid responsiveness: an update
Monnet, X., Marik, P. E., & Teboul, J.-L. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0216-7 · Cited by 600
Comparison of Echocardiographic Indices Used to Predict Fluid Responsiveness in Ventilated Patients
Vignon, P., Repessé, X., Bégot, E., Léger, J., Jacob, C., Bouferrache, K., Slama, M., Prat, G., & Vieillard-Baron, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0844oc · Cited by 308
Ehrman, R. R., Sullivan, A. N., Favot, M. J., Sherwin, R. L., Reynolds, C. A., Abidov, A., & Levy, P. D. (2018) · Critical Care · doi:10.1186/s13054-018-2043-8 · Cited by 284
Metadata
- Authors
- Cherpanath, T. G. V., Hirsch, A., Geerts, B. F., Lagrand, W. K., Leeflang, M. M., Schultz, M. J., & Groeneveld, A. B. J.
- Affiliations
- Erasmus MC (NL)
- ORCID
- Venue
- Critical Care Medicine
- Published
- 2016-05
- Volume
- 44
- Issue
- 5
- Pages
- 981-991
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2231155641
- Semantic Scholar
- 4502cac799627c29edb12c20f32e4af15985ae51
- Cited by
- 253
- References
- 74
- Citations by year
- 2026: 16 · 2025: 23 · 2024: 14 · 2023: 38 · 2022: 18 · 2021: 33 · 2020: 24 · 2019: 24 · 2018: 22 · 2017: 24 · 2016: 16
- FWCI
- 5.67
- Type
- journal article
- Language
- en
- Open access
- green
- pure.amsterdamumc.nl
- Licence
- other-oa
- Locations
- Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion, other-oa)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion)
- Funders
- Edwards Lifesciences
- Topics
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Sepsis Diagnosis and Treatment
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
- Keywords
- passive leg raising, fluid responsiveness, fluid challenge, venous return, diagnostic accuracy, sensitivity and specificity, pulse pressure, cardiac output, hemodynamic monitoring, mechanical ventilation
- MeSH terms
- Blood Pressure, Cardiac Output, Fluid Therapy, Hemodynamics, Humans, Leg, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.