Effects of norepinephrine on mean systemic pressure and venous return in human septic shock*
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Norepinephrine exerts venoconstriction that could increase both the mean systemic pressure and the resistance to venous return, but this has not yet been investigated in human septic shock. We examined the relative importance of both effects and the resulting effect on venous return when decreasing the dose of norepinephrine. SETTING: Intensive care unit. PATIENTS: Sixteen septic shock patients. MEASUREMENTS: For estimating the venous return curve, we constructed the regression line between the pairs of cardiac index (pulse contour analysis) and central venous pressure values. These values were measured during 15-sec end-inspiratory and end-expiratory ventilatory occlusions performed at two levels of positive end-expiratory pressure, in view of widening the range of cardiac index:central venous pressure measurements and increasing the accuracy of the regression line. The x-axis intercept of the regression line was used to estimate the mean systemic pressure and the inverse of the slope of the regression line to quantify resistance to venous return. These measurements were obtained before and after decreasing the dose of norepinephrine. Passive leg raising was performed before and after decreasing the dose of norepinephrine. MAIN RESULTS: Decreasing the dose of norepinephrine from 0.30 (0.10-1.40) to 0.19 (0.08-1.15) µg/kg/min decreased the mean systemic pressure from 33 ± 12 mm Hg to 26 ± 10 mm Hg (p = .0003). The slope of the multipoint cardiac index:central venous pressure relationship increased (p = .02). The resistance to venous return decreased, i.e., 1/slope decreased. Simultaneously, cardiac index decreased from 3.47 ± 0.86 L/min/m2 to 3.28 ± 0.76 L/min/m (p = .04), indicating a decrease in venous return. Passive leg raising increased cardiac index to a larger extent after (8% ± 4%) than before (1% ± 4%) decreasing norepinephrine (p = .001), suggesting an increase in unstressed blood volume at the lowest dose of norepinephrine. CONCLUSIONS: In septic shock patients, decreasing the dose of norepinephrine decreased the mean systemic pressure and, to a lesser extent, the resistance to venous return. As a result, venous return decreased.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mercat, A., Richard, J.-C. M., Vielle, B., Jaber, S., Osman, D., Diehl, J.-L., Lefrant, J.-Y., Prat, G., Richecoeur, J., Nieszkowska, A., et al. (2008) · JAMA · doi:10.1001/jama.299.6.646 · Cited by 1,344
Passive leg raising predicts fluid responsiveness in the critically ill*
Monnet, X., Rienzo, M., Osman, D., Anguel, N., Richard, C., Pinsky, M. R., & Teboul, J.-L. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000215453.11735.06 · Cited by 952 · cited 1×
“The effects of a passive leg raising test on the pulse contour analysis– derived CI were assessed, as previously described (17, 18).”
MethodSelf-citationVenous Return at Various Right Atrial Pressures and the Normal Venous Return Curve
Guyton, A. C., Lindsey, A. W., Abernathy, B., & Richardson, T. (1957) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1957.189.3.609 · Cited by 544 · cited 4×
“Nevertheless, there are no physiological arguments to suggest that it should not be true (15).”
BackgroundMethodInfluentialGlobal End-Diastolic Volume as an Indicator of Cardiac Preload in Patients With Septic Shock *
Michard, F., Alaya, S., Zarka, V., Bahloul, M., Richard, C., & Teboul, J.-L. (2003) · Chest · doi:10.1378/chest.124.5.1900 · Cited by 352 · cited 1×
“It is con sidered as a marker of preload (12).”
BackgroundSelf-citationRobotham, J. L., Takata, M., Berman, M., & Harasawa, Y. (1991) · Anesthesiology · doi:10.1097/00000542-199101000-00026 · Cited by 272 · cited 1×
“Given the physiological relationship between left ventricular ejection fraction and left ventricular afterload (38), the fact that the cardiac function index did not change while systolic arterial pressure decreased suggests that decreasing the dose of nor epinephrine decreased the left ventricular contractility.”
BackgroundVascular hyporesponsiveness to vasopressors in septic shock: from bench to bedside
Levy, B., Collin, S., Sennoun, N., Ducrocq, N., Kimmoun, A., Asfar, P., Perez, P., & Meziani, F. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-2045-8 · Cited by 218 · cited 1×
“Norepinephrine exerts powerful arterial vasoconstrictive effects allowing to restore the mean arterial pressure (1).”
BackgroundHamzaoui, O., Georger, J.-F., Monnet, X., Ksouri, H., Maizel, J., Richard, C., & Teboul, J.-L. (2010) · Critical Care · doi:10.1186/cc9207 · Cited by 206 · cited 2×
“Recent studies showed that norepinephrine can also increase cardiac preload (3, 4) and cardiac output in case of preload dependence (3).”
BackgroundResultSelf-citationPrecision of the transpulmonary thermodilution measurements
Monnet, X., Persichini, R., Ktari, M., Jozwiak, M., Richard, C., & Teboul, J.-L. (2011) · Critical Care · doi:10.1186/cc10421 · Cited by 194 · cited 1×
“Calibration of pulse contour analysis–derived estimation of stroke volume was performed by using transpulmo nary thermodilution, with injection of three cold saline boluses (15 mL each) (11).”
MethodSelf-citationMonnet, X., Jabot, J., Maizel, J., Richard, C., & Teboul, J.-L. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e318206d2a3 · Cited by 185
Self-citationHamzaoui, O., Monnet, X., Richard, C., Osman, D., Chemla, D., & Teboul, J.-L. (2008) · Critical Care Medicine · doi:10.1097/01.ccm.ob013e318161fec4 · Cited by 179 · cited 1×
“As a result, the minimal changes in CI we measured (between inspiratory and expiratory occlusions at PEEP = 5 cm H2O) were far above the precision of pulse contour analysis for measuring CI (29, 30).”
Self-citationCentral venous pressure: A useful but not so simple measurement
Magder, S. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000227646.98423.98 · Cited by 174 · cited 1×
“, on the axillary line, 5 cm below the sternal angle (10), and zeroing was performed against atmospheric pressure.”
BackgroundEstimation of left ventricular systolic function by single transpulmonary thermodilution
Combes, A., Berneau, J.-B., Luyt, C. E., & Trouillet, J. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2289-2 · Cited by 149 · cited 1×
“The cardiac function index is an estimation of the left ven tricular systolic function (13, 14).”
Effects of Positive End-expiratory Pressure on the Canine Venous Return Curve
Fessler, H. E., Brower, R. G., Wise, R. A., et al. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/146.1.4 · Cited by 146
Monnet, X., Anguel, N., Naudin, B., Jabot, J., Richard, C., & Teboul, J. (2010) · Critical Care · doi:10.1186/cc9058 · Cited by 140 · cited 1×
“As a result, the minimal changes in CI we measured (between inspiratory and expiratory occlusions at PEEP = 5 cm H2O) were far above the precision of pulse contour analysis for measuring CI (29, 30).”
Self-citationMueller, H. S., Ayres, S. M., Gregory, J., Giannelli, S., & Grace, W. J. (1970) · Journal of Clinical Investigation · doi:10.1172/jci106408 · Cited by 117 · cited 1×
“This allows a rapid restoration of arterial pressure (19) and might increase the coronary blood flow (20).”
BackgroundPinsky, M. R. (2007) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3282efad97 · Cited by 109
Skomedal, T., Borthne, K., Aass, H., Geiran, O. R., & Osnes, J. (1997) · Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(24)36448-1 · Cited by 91 · cited 1×
“Norepinephrine might also exert an inotropic effect through β1 and, to a lesser extent, α1adrenergic stimulation (21).”
BackgroundComparative effects of early versus delayed use of norepinephrine in resuscitated endotoxic shock*
Sennoun, N., Montemont, C., Gibot, S., Lacolley, P., & Levy, B. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000269028.28521.08 · Cited by 90 · cited 1×
“In animals with endotoxinic shock, the use of catecholamines is associated with a lesser amount of delivered fluid (5).”
BackgroundStatic filling pressure in patients during induced ventricular fibrillation
Schipke, J. D., Heusch, G., Sanii, A. P., et al. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00604.2003 · Cited by 77 · cited 1×
“The range of mean systemic pressures we observed in our patients was in the same range than reported in human stud ies (7, 31, 32) but higher than observed in previous animal studies (6, 22, 28, 33–35).”
ResultHemodynamic effects of passive leg raising: an echocardiographic study in patients with shock
Caille, V., Jabot, J., Belliard, G., Charron, C., Jardin, F., & Vieillard‐Baron, A. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1067-y · Cited by 68 · cited 1×
“The effects of a passive leg raising test on the pulse contour analysis– derived CI were assessed, as previously described (17, 18).”
Method
Cited by
Sepsis: pathophysiology and clinical management
Gotts, J. E., & Matthay, M. A. (2016) · BMJ · doi:10.1136/bmj.i1585 · Cited by 1,243
Myburgh, J. A., & Mythen, M. G. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1208627 · Cited by 631
2023 Update on Sepsis and Septic Shock in Adult Patients: Management in the Emergency Department
Guarino, M., Perna, B., Cesaro, A. E., Maritati, M., Spampinato, M. D., Contini, C., & De Giorgio, R. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12093188 · Cited by 294
A rational approach to fluid therapy in sepsis
Marik, P., & Bellomo, R. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aev349 · Cited by 261
Prediction of fluid responsiveness. What’s new?
Monnet, X., Shi, R., & Teboul, J.-L. (2022) · Annals of Intensive Care · doi:10.1186/s13613-022-01022-8 · Cited by 249
“Alternatives to fluid may be considered for improving the haemodynamic status, as using the preload effect of norepinephrine in septic shock patients [95, 96] or simply decreasing the level of PEEP, for instance.”
BackgroundSelf-citation
Metadata
- Authors
- Persichini, R., Silva, S., Teboul, J.-L., Jozwiak, M., Chemla, D., Richard, C., & Monnet, X.
- Venue
- Critical Care Medicine
- Published
- 2012-12
- Volume
- 40
- Issue
- 12
- Pages
- 3146-3153
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2074693408
- Cited by
- 218
- References
- 20
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.