Differences in night-time and daytime ambulatory blood pressure when diurnal periods are defined by self-report, fixed-times, and actigraphy: Improving the Detection of Hypertension study
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To determine whether defining diurnal periods by self-report, fixed-time, or actigraphy produce different estimates of night-time and daytime ambulatory blood pressure (ABP). METHODS: Over a median of 28 days, 330 participants completed two 24-h ABP and actigraphy monitoring periods with sleep diaries. Fixed night-time and daytime periods were defined as 0000-0600 h and 1000-2000 h, respectively. Using the first ABP period, within-individual differences for mean night-time and daytime ABP and kappa statistics for night-time and daytime hypertension (systolic/diastolic ABP≥120/70 mmHg and ≥135/85 mmHg, respectively) were estimated comparing self-report, fixed-time, or actigraphy for defining diurnal periods. Reproducibility of ABP was also estimated. RESULTS: Within-individual mean differences in night-time systolic ABP were small, suggesting little bias, when comparing the three approaches used to define diurnal periods. The distribution of differences, represented by 95% confidence intervals (CI), in night-time systolic and diastolic ABP and daytime systolic and diastolic ABP was narrowest for self-report versus actigraphy. For example, mean differences (95% CI) in night-time systolic ABP for self-report versus fixed-time was -0.53 (-6.61, +5.56) mmHg, self-report versus actigraphy was 0.91 (-3.61, +5.43) mmHg, and fixed-time versus actigraphy was 1.43 (-5.59, +8.46) mmHg. Agreement for night-time and daytime hypertension was highest for self-report versus actigraphy: kappa statistic (95% CI) = 0.91 (0.86,0.96) and 1.00 (0.98,1.00), respectively. The reproducibility of mean ABP and hypertension categories was similar using each approach. CONCLUSION: Given the high agreement with actigraphy, these data support using self-report to define diurnal periods on ABP monitoring. Further, the use of fixed-time periods may be a reasonable alternative approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Standards of medical care in diabetes—2014
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s014 · Cited by 4,572
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Cheung, A. K., Chang, T. I., Cushman, W. C., Furth, S. L., Hou, F. F., Ix, J. H., Knoll, G. A., Muntner, P., Pecoits-Filho, R., Sarnak, M. J., et al. (2021) · Kidney International · doi:10.1016/j.kint.2020.11.003 · Cited by 1,452
Self-citationEuropean Society of Hypertension practice guidelines for ambulatory blood pressure monitoring
Parati, G., Stergiou, G., O’Brien, E., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000221 · Cited by 1,021
Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study
Boggia, J., Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Kuznetsova, T., Torp-Pedersen, C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61538-4 · Cited by 887 · cited 2×
“Fixed-time periods were defined by the International Database of ABP in relation to Cardiovascular Outcome criteria for Europeans [night-time: 0000–0600 h (6 h), daytime: 1000–2000 h (10 h)] [6,19].”
BackgroundMethodFagard, R. H., Celis, H., Thijs, L., Staessen, J. A., Clement, D. L., De Buyzere, M. L., & De Bacquer, D. A. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.100727 · Cited by 742
Predictive Role of the Nighttime Blood Pressure
Hansen, T. W., Li, Y., Boggia, J., Thijs, L., Richart, T., & Staessen, J. A. (2011) · Hypertension · doi:10.1161/hypertensionaha.109.133900 · Cited by 597
Nocturnal blood pressure and cardiovascular disease: a review of recent advances
Yano, Y., & Kario, K. (2012) · Hypertension Research · doi:10.1038/hr.2012.26 · Cited by 227 · cited 1×
“com Night-time ABP and nondipping BP status have been associated with increased risk for CVD outcomes and mortality, independent of mean daytime ABP [25,26].”
Background
Cited by
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“One study showed higher agreement in daytime and nocturnal BP between self-report and actigraphy than between either self-report and fixed time or fixed time and actigraphy.(100) Selfreport is the most pragmatic approach in clinical practice to define sleep and awake periods.”
BackgroundSelf-citationMorawski, K., Ghazinouri, R., Krumme, A., Lauffenburger, J. C., Lu, Z., Durfee, E., Oley, L., Lee, J., Mohta, N., Haff, N., et al. (2018) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2018.0447 · Cited by 333
Reproducibility study of nocturnal blood pressure dipping in patients with high cardiovascular risk
Burgos‐Alonso, N., Ruiz Arzalluz, M. V., Garcia‐Alvarez, A., Fernandez‐Fernandez de Quincoces, D., & Grandes, G. (2021) · The Journal of Clinical Hypertension · doi:10.1111/jch.14222 · Cited by 19
“29,31,33 Omboni et al observed a reproducibility of 60.3% considering SBP and 60.9% considering DBP. 18 Gorostidi et al 34 and at Booth et al study 35 noted that the non-dipper pattern is more common and the reproducibility is slightly higher in high-risk patients than in other groups.”
BackgroundInfluential
Metadata
- Authors
- Booth, J. N., Muntner, P., Abdalla, M., Diaz, K. M., Viera, A. J., Reynolds, K., Schwartz, J. E., & Shimbo, D.
- Venue
- Journal of Hypertension
- Published
- 2016-02
- Volume
- 34
- Issue
- 2
- Pages
- 235-243
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2427351222
- Cited by
- 50
- References
- 11
- FWCI
- 2.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Differences in night-time and daytime ambulatory blood pressure when diurnal periods are defined by self-report, fixed-times, and actigraphy: Improving the Detection of Hypertension study. https://app.cochat.ai/papers/10.1097/hjh.0000000000000791
- The paper
- Booth, J. N., Muntner, P., Abdalla, M., Diaz, K. M., Viera, A. J., Reynolds, K., Schwartz, J. E., & Shimbo, D. (2016). Differences in night-time and daytime ambulatory blood pressure when diurnal periods are defined by self-report, fixed-times, and actigraphy: Improving the Detection of Hypertension study. Journal of Hypertension. https://doi.org/10.1097/hjh.0000000000000791
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.