Sources of inaccuracy in the measurement of adult patients’ resting blood pressure in clinical settings: a systematic review
Open accessThe DOI matches its Crossref record; 386 of the 390 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
BACKGROUND: To interpret blood pressure (BP) data appropriately, healthcare providers need to be knowledgeable of the factors that can potentially impact the accuracy of BP measurement and contribute to variability between measurements. METHODS: A systematic review of studies quantifying BP measurement inaccuracy. Medline and CINAHL databases were searched for empirical articles and systematic reviews published up to June 2015. Empirical articles were included if they reported a study that was relevant to the measurement of adult patients' resting BP at the upper arm in a clinical setting (e.g. ward or office); identified a specific source of inaccuracy; and quantified its effect. Reference lists and reviews were searched for additional articles. RESULTS: A total of 328 empirical studies were included. They investigated 29 potential sources of inaccuracy, categorized as relating to the patient, device, procedure or observer. Significant directional effects were found for 27; however, for some, the effects were inconsistent in direction. Compared with true resting BP, significant effects of individual sources ranged from -23.6 to +33 mmHg SBP and -14 to +23 mmHg DBP. CONCLUSION: A single BP value outside the expected range should be interpreted with caution and not taken as a definitive indicator of clinical deterioration. Where a measurement is abnormally high or low, further measurements should be taken and averaged. Wherever possible, BP values should be recorded graphically within ranges. This may reduce the impact of sources of inaccuracy and reduce the scope for misinterpretations based on small, likely erroneous or misleading, changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“On a beat-to-beat basis, BP levels can vary markedly (from –24 mmHg to 33 mmHg) in response to usual extrinsic and behavioural factors4”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [4]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“the highly variable nature of office and out-of-office BP readings has been widely acknowledged”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [4]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Standardization is essential because there are many aspects of BP measurement, including the patient’s physical condition, clinic environment, and equipment that can readily result in inaccurate and unreliable values.23,25,26”
From International Consensus on Standardized Clinic Blood Pressure Measurement – A Call to Action (2023) · cites this paper as [25]
In the citing paper
“Even when a validated automated device is used, the accuracy of BP measurement may be influenced by many factors. 19 – 21”
From Hypertension Canada guideline for the diagnosis and treatment of hypertension in adults in primary care (2025) · cites this paper as [19]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
The Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220 · cited 1×
“Therefore, when interpreting the accuracy of a device, both the mean bias and the width of the limits of agreement should be considered [165,166].”
BackgroundPickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051 · cited 4×
“Generally, this change is assumed to involve an increase in both SBP and DBP from normal daytime values [4].”
BackgroundMethodInfluentialHuman blood pressure determination by sphygmomanometry.
Perloff, D., Grim, C., Flack, J., Frohlich, E. D., Hill, M., McDonald, M., & Morgenstern, B. Z. (1993) · Circulation · doi:10.1161/01.cir.88.5.2460 · Cited by 1,591
Williams, B., Poulter, N. R., Brown, M. J., Davis, M., McInnes, G. T., Potter, J. F., Sever, P. S., & McG Thom, S. (2004) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001683 · Cited by 1,272
Effects of Caffeine on Plasma Renin Activity, Catecholamines and Blood Pressure
Robertson, D., Frölich, J. C., Carr, R. K., Watson, J. T., Hollifield, J. W., Shand, D. G., & Oates, J. A. (1978) · New England Journal of Medicine · doi:10.1056/nejm197801262980403 · Cited by 757
Cited by
Items 301–400 of 422
Improving Hypertension and Diabetes Mellitus Control with a Dedicated Patient Navigator
Marsden, J. E., Zhang, J., Bays, C., Schumann, S. O., Schreiner, A. D., Khan, A., Mauldin, P. D., Davis, K. S., & Moran, W. P. (2024) · Southern Medical Journal · doi:10.14423/smj.0000000000001745 · Cited by 1
How useful is a casual BP measurement?
Lewis, P. (2026) · Clinical Medicine · doi:10.1016/j.clinme.2026.100626 · Cited by 1
Mennitto, S. (2023) · eScholarship@McGill (McGill) · doi:10.82308/27877 · Cited by 1
Methodology of Office Blood Pressure Measurement
Brady, T. M. (2022) · Springer eBooks · doi:10.1007/978-3-319-31420-4_42-2 · Cited by 1
Medical Device Safety-an E-Guide for Nursing Students
Kimeli, J., & Otieno, R. (2025) · Theseus (Ammattikorkeakoulujen) · Cited by 1
Lacunza, C. D., Castellano, M. R., Feixes, M. A., Cardozo, R. M., Cáceres, A. B., & Guillou, M. A. S. (2025) · Revista Argentina de Cardiología · doi:10.7775/rac.es.v89.i3.19631 · Cited by 1
Management of hypertensive urgencies: a new opportunity for unattended blood pressure measurement
Robles, N. R., Fıcı, F., & Grassi, G. M. (2024) · Journal of Human Hypertension · doi:10.1038/s41371-024-00907-4 · Cited by 1
Automated blood pressure measurement may not improve efficiency if manual technique was suboptimal
Boonyasai, R. T., Dietz, K. B., McCannon, E. L., & Cooper, L. A. (2018) · Journal of Clinical Hypertension · doi:10.1111/jch.13263 · Cited by 1
Cutolo, C. A., Vercellin, A. C. V., Desideri, L. F., Bonzano, C., Piccolino, F. C., Traverso, C. E., & Nicolò, M. (2020) · Modeling and Artificial Intelligence in Ophthalmology · doi:10.35119/maio.v2i4.109 · Cited by 1
Intensify Stroke Prediction Model Associated with Hypertensive State
Islam, M. R., Rahman, M. S., Paul, R. R., Hosen, M. F., Khairunnahar, M., & Nayeem, M. J. (2024) · International Conference on Advancement in Electrical and Electronic Engineering (ICAEEE) · doi:10.1109/icaeee62219.2024.10561847 · Cited by 1
When Routine Errors Matter: The Effect of Non-Standardized Blood Pressure MeasurementPreprint
Vesga-Reyes, P. A., Zapata-Vasquez, I. L., Carrillo, D. C., Gómez‐Mesa, J. E., León-Giraldo, H., & Vesga-Reyes, C. E. (2026) · medRxiv · doi:10.64898/2026.02.26.26347228
Vazeou, A., & Stergiou, G. S. (2022) · Biomarkers in disease · doi:10.1007/978-3-030-81303-1_37-1
Okubai, T., Kahsay, D. T., Netsereab, T. B., & Asnake, M. A. (2025) · SAGE Open Nursing · doi:10.1177/23779608251403037
Goupil, R., Tsuyuki, R. T., Santesso, N. A., Terenzi, K. A., Habert, J., Cheng, G., Gysel, S. C., Bruneau, J., Leung, A. A. C., Campbell, N. R. C., et al. (2025) · Canadian Pharmacists Journal / Revue des Pharmaciens du Canada · doi:10.1177/17151635251352537
Gästgivars, O., Ögren, J., Carlberg, B., & Brunström, M. (2026) · Journal of Internal Medicine · doi:10.1111/joim.70164
Blood Pressure Control and Mortality Among US Veterans
Yamada, M., Griffin, B. R., Shi, Q., Sambharia, M., Swee, M. L., Good, M. K., Kennelty, K. A., Faro, E. Z., Reisinger, H. S., Girotra, S. R., et al. (2026) · Hypertension · doi:10.1161/hypertensionaha.125.25787
Leveraging the Electronic Health Record to Identify and Manage Resistant Hypertension
Shankar, B., Ben-Shlomo, A., Cheng, S. C., & Ebinger, J. E. (2026) · Current Hypertension Reports · doi:10.1007/s11906-026-01371-w
Disparities in Blood Pressure Measurement
Ali, A., Salman, L. A., & Cohen, J. B. (2026) · Current Hypertension Reports · doi:10.1007/s11906-026-01391-6
Vazeou, A., & Stergiou, G. S. (2022) · Biomarkers in disease · doi:10.1007/978-3-031-08014-2_37
Patel, M. K., Timko-Swaim, L., Conklin, P., & Lu, W.-H. (2026) · Journal of Clinical Hypertension · doi:10.1111/jch.70234
Garg, R., & Sathe, S. (2023) · International Journal of Advanced Research in Medicine · doi:10.22271/27069567.2023.v5.i3a.493
Teaching Analytics Medical-Data Common Sense
Sagi, T., Shmueli, N., Friedman, B., & Bergman, R. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-71055-2_14
Fangman, A., Gannavaram, S., Steinbeck, M., Adler, R. S., Khan, A. W., & Fu, Z. (2025) · medRxiv · doi:10.1101/2025.08.18.25333937
Lu, Y., Linderman, G. C., Mahajan, S., Liu, Y., Mortazavi, B. J., Huang, C., Khera, R., Spatz, E. S., & Krumholz, H. M. (2021) · medRxiv · doi:10.1101/2021.08.18.21262255
Warneke, K., Lebelt, N., Liebermann, F., Jöst, B., & Herbsleb, M. (2026) · BMC Cardiovascular Disorders · doi:10.1186/s12872-026-06262-1
The sine transform is the sine qua non of the pulmonary and systemic pressure relationship
Doyle, M., Rayarao, G., & Biederman, R. W. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1120330
Bankanie, V., Lilngulu, A., & Li, Y. (2020) · Research Square · doi:10.21203/rs.2.22073/v1
Turner, W., Marca, R. L., Infanger, D., Brühl, A. B., Marschall, K., Schulze, B., Pfaff, M., Russmann, T., Böker, H., & Schmidt‐Trucksäss, A. (2026) · Journal of Affective Disorders Reports · doi:10.1016/j.jadr.2026.101065
Ishaku, S. (2021) · Utrecht University Repository (Utrecht University) · doi:10.33540/661
Hypertension and the metabolic syndrome: toward personalized management
Neeland, I. J., & Dobre, M. A. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-99991-5.00019-x
Васильевич, И. М., Emelyanov, I. V., Vashchenkov, V. V., Voronin, Y. P., Gaibaliev, E. E., Kovalchuk, S. V., & Конради, А. О. (2026) · Translational Medicine · doi:10.18705/2311-4495-2026-13-4-359-370
Godec, T. R. (2021) · LSHTM Research Online (London School of Hygiene and Tropical Medicine) · doi:10.17037/pubs.04663959
Kim, B. S., Lim, Y.-H., Kim, W., Kook, H., Shin, J., Lee, Y., Heo, R., Kim, H.-J., & Shin, J. S. (2024) · Figshare · doi:10.6084/m9.figshare.26133604
Delva, W., & Posthumus, C. (2022) · OSF Preprints (OSF Preprints) · doi:10.31219/osf.io/sgzqb
Imada, H., Toma, R., Hata, S., Katano, M., Nishida, Y., Soga, T., Yoshida, K., Sakaji, I., 元山, 明., & Hananouchi, T. (2026) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-026-01060-8
Hiremath, S. S. (2022) · Wiley eBooks · doi:10.1002/9781119105954.ch22
Lobo, I. E., Koon, K., Potthast, K. L., Ozmina, K., & Billups, S. J. (2025) · Population Health Management · doi:10.1177/19427891251393941
Handling Errors in eHealth Sensors Using Interval Mapping and Fuzzy Modeling
Gupta, A., Nag, A., & Mukherjee, N. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3054643
Chellappan, A., & Kansal, K. (2024) · Journal of Family Medicine and Primary Care · doi:10.4103/jfmpc.jfmpc_1619_23
Intraoperative Hypotension and Risk of Cuff Blood Pressure Inaccuracy
Kwon, S., Kim, S., Cole, D. J., Bovik, A. C., Legrand, M., Giovannucci, E. L., & Cannesson, M. P. (2026) · Hypertension · doi:10.64898/2026.07.20.26358528
Buettner, T., Bertram, A. K., Floyd, O., Dowd-Green, C., & Stewart, R. W. (2021) · Primary Health Care · doi:10.7748/phc.2021.e1695
Lacy, P. S., Jedrzejewski, D., McFarlane, E., & Williams, B. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003415
Blood Pressure Protocol: Processing Time of Standard Versus Automated
Gaines, M., Black, P. C., Ito, K., Wallace, T., Gomez, S., & Biola, H. R. (2025) · PRiMER · doi:10.22454/primer.2025.708390
Parker, R. A., Padfield, P. L., Hanley, J., Pinnock, H., Kennedy, J., Stoddart, A., Hammersley, V., Sheikh, A., & McKinstry, B. (2021) · Figshare · doi:10.6084/m9.figshare.13889173
Stewart, P., Stewart, J., Noble, R. A., Hörner, D. V., Taal, M. W., & Selby, N. M. (2023) · Engineering Archive (engrXiv) · doi:10.31224/2987
Hedetoft, K., Lihme, F., & Lykke, J. A. (2022) · Danish Journal of Obstetrics and Gynaecology · doi:10.56182/djog.v1i1.12
New perspectives in taming resistant hypertension
Caraus, A., Cociu, M., Moiseeva, A., & Popescu, L. (2024) · Bulletin of the Academy of Sciences of Moldova Medical Sciences · doi:10.52692/1857-0011.2024.1-78.14
Kang, S.-J., Han, S.-Y., Kim, T. H., & Lee, S.-W. (2026) · doi:10.2196/preprints.94893
Global Hypertension Guidelines: Are Central Haemodynamics Critical and Neglected
Phillips, R. A., CARLIER, S. G., Scalia, A., Delmotte, P., CATTERMOLZ, G. N., & Brierley, J. (2023) · Anesthesia and Critical Care · doi:10.26502/acc.064
Kang, M. K. (2024) · Journal of the Korean Neurological Association · doi:10.17340/jkna.2024.0014
Gangadharan, N., Baskaran, B., Manavalan, A., Praveenkumar, M., Anandhakumar, M., Jebaraj, B., Devasahayam, S. R., & Subramani, S. (2026) · medRxiv · doi:10.64898/2026.10.01.26364471
Sobana, R., Ganesh, D. D. A., Jaiganesh, K., & Parthasarathy, S. (2022) · International Journal of Life Science and Pharma Research · doi:10.22376/ijpbs/lpr.2022.12.6.sp25.l34-40
Performance of an automated blood pressure measurement device in a stroke rehabilitation unit
Lamarre-Cliché, M., Spacek, E., Houde, S., Furgé, P., Lamarre, C., Duong, Y. N., Tran, G., & Beaudoin, N. (2020) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000484
Kalçık, M., & Bayam, E. M. (2025) · Journal of Clinical Hypertension · doi:10.1111/jch.70134
Lins, R. L. (2023) · Acta Clinica Belgica · doi:10.1080/17843286.2023.2205676
Treatment of asymptomatic hypertension during hospitalization - less is often much more
Zelinka, T. (2024) · Vnitřní lékařství · doi:10.36290/vnl.2024.036
Identifying hypertension during the NHS Health Check
Botelle, C. (2026) · Practice Nursing · doi:10.12968/pnur.2025.0101
Guo, X. (2026) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000818
Wang, Q., Shen, Z., Sun, Y., Shi, K., Zhou, Y., & Huang, S. (2026) · Journal of the American Heart Association · doi:10.1161/jaha.125.047858
Simulation-Based Assessment of Blood Pressure by Certified Athletic Trainers
Verde, M. W., Eberman, L. E., Emerson, D. M., Foster, Z. J., & Winkelmann, Z. K. (2025) · Internet Journal of Allied Health Sciences and Practice · doi:10.46743/1540-580x.2752
Gregory, P. (2025) · Journal of Paramedic Practice · doi:10.12968/jpar.2025.0017
Malm, E., Petersen, A. N., Hadad, R., Haugaard, S. B., Olsen, M. H., Bonde, P. L., Domínguez, H., Hadziselimovic, E., & Sajadieh, A. (2025) · Journal of Hypertension · doi:10.1097/hjh.0000000000004027
Bergholz, A., Meidert, A. S., Flick, M., Krause, L., Vettorazzi, E., Zapf, A., Brunkhorst, F. M., Meybohm, P., Zacharowski, K., Zarbock, A., et al. (2022) · Figshare · doi:10.6084/m9.figshare.21582404
Agreement between Student Paramedics When Measuring Blood Pressure
Hutchins, A., Momo, A. T., Tran, L., Thyer, L., & Simpson, P. (2019) · Australasian Journal of Paramedicine · doi:10.33151/ajp.16.630
Minari, T. P., Pisani, L. P., Rubio, T. D. A., Yugar, L. B. T., Sedenho‐Prado, L. G., Cosenso‐Martin, L. N., Tácito, L. H. B., Moreno, H., Vilela-Martin, J. F., & Yugar‐Toledo, J. C. (2025) · Diabetology · doi:10.3390/diabetology6090094
Apriliando, E. (2020) · ScholarWorks - GVSU (Grand Valley State University)
A Novel Instrument for Research and Calibration of Noninvasive Blood Pressure Measurement
Celler, B. G., Rudino, R., & Argha, A. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3731732
Staff Education: Improving Hypertension Management among African American Adults
Tunis-Blanc, M. S. (2023) · ScholarWorks (Walden University)
Hypertension in Patients Receiving Maintenance Hemodialysis: Beyond Sodium and Dry Weight
Najjar, C., McCormick, B. B., & Canney, M. (2026) · Advances in Kidney Disease and Health · doi:10.1053/j.akdh.2026.07.005
Acta Bioclínica Volúmen 13, N° 26: Julio - Diciembre 2023
- (2023) · Acta Bioclínica
Yang, E., & Tang, O. (2023) · JACC Advances · doi:10.1016/j.jacadv.2023.100405
Bahadoran, Z., Mirmiran, P., Ghasemi, A., & Azizi, F. (2025) · Clinical Hypertension · doi:10.5646/ch.2025.31.e4
Smith, W. N., Signorile, J. F., Seixas, A. A., Chung, D. P., Larsen, B., & Flanagan, C. P. (2026) · Journal of Clinical Hypertension · doi:10.1111/jch.70379
Access to Care for Cardiometabolic Diseases in Low- and Middle-Income Countries
Marcus, M. E. (2023) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-9662
Ganbold, O. (2025) · Carleton University's Institutional Repository (MacOdrum Library, Carleton University) · doi:10.22215/etd/2025-16781
The Latest Hypertension Guidelines At-a-Glance: No Need for a QR Code
Ram, C. V. S., & Wander, G. S. (2023) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2023.11.068
As-Needed Treatment of Postoperative Hypertension for Inpatient Surgical Patients: A Review
Bakkila, B. F., & Wren, S. M. (2026) · JAMA Surgery · doi:10.1001/jamasurg.2026.2059
Blair, J. P., Kempf, M.-C., Dionne, J. A., Pruitt, Z. C., Brown, T. T., DʼSouza, G., Wise, J., Jackson, E. A., Muntner, P., Hanna, D. B., et al. (2026) · Scientific Reports · doi:10.1038/s41598-026-69246-3
Towards Optimal Use of Home BP Monitoring Technology: Incorporating Patient Perspectives
Padwal, R. S., & Cluett, J. (2024) · American Journal of Hypertension · doi:10.1093/ajh/hpae107
Çobanoğlu, A., & Yılmaz, E. B. (2024) · Journal of Clinical Medicine of Kazakhstan · doi:10.23950/jcmk/14964
Yousif, N. G., Hadi, N. R., & Al-Amran, F. G. (2023) · BENTHAM SCIENCE PUBLISHERS eBooks · doi:10.2174/9789815196894123010003
Nwajiobi, C. E., Basil, B., & Okoli, U. J. (2024) · PubMed Central · doi:10.60787/nmj-v65i3-405
Safira, E. S., Sarwono, B., & Kriswoyo, P. G. (2024) · Innovation in Health for Society · doi:10.31603/ihs.11754
Richard, C. (2022) · Archipel (Université du Québec à Montréal)
Impact of Blood Pressure Measurement Errors on CVD Risk Prediction in New Zealand
Chandel, T. (2025) · Tuwhera (Auckland University of Technology)
A Cross-Sectional Study on Inter-Arm Blood Pressure Difference among Healthy Young Adults
Khan, M., Din, Z., Farooq, S., Mobin, A., Hasan, F., & Idrees, S. H. (2022) · Pakistan Journal of Medical and Health Sciences · doi:10.53350/pjmhs22167457
聴診法による血圧の変動量評価に基づく生体計測法の標準化に関する研究
Yamashita, S. (2026) · Institutional Repositories DataBase (IRDB) · doi:10.20556/0002008393
Basic Quality Care Blood Pressure Teaching Plan
Lynch, D. A. (2019) · ScholarWorks (Walden University)
Machine learning methods for tabular electronic health record data
O'Donoghue, O. (2023) · Oxford University Research Archive (ORA) (University of Oxford) · doi:10.5287/ora-dez6rr1v2
Ramírez-González, J. B., Sharma-Sharma, S., Osorio-Juárez, R. A., Galindo-Uribe, J., Payró-Ramírez, G., Reyes-Antonio, D. J., Hernández-Franco, B., Martínez-Nevarez, I., Méndez-Cobos, R. A., Rodríguez-García, J. K., et al. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1977185
Is it time we consider treating blood pressure measurement as a real medical test?
McGinnis, A. M., & Bisognano, J. D. (2021) · International Journal of Cardiology Hypertension · doi:10.1016/j.ijchy.2021.100097
Onkolojik Tedaviye Bağlı Arteriyel Hipertansiyon
Can, F. (2021) · Akademisyen Kitabevi eBooks · doi:10.37609/akya.42.c4234
Gałczyńska, O., Cecot, Z. Z., Kucharski, J. J., Lesiczka, M. M., Duszejko, J. W., Lenartowicz, F., Maciaszczyk, A. M., Kuklińska, K., Lewczuk, A. M., & Mazurek, D. O. (2026) · Quality in Sport · doi:10.12775/qs.2026.79.76805
Coach-BP: Computer Vision-Based Assessment and Correction of Blood Pressure Measurement TechniquePreprint
Biswas, R., Abad, A. J., Nugas, J., Shim, J. E., Pletcher, M. J., Lamprea-Montealegre, J. A., & Abbasi-Asl, R. (2026) · medRxiv · doi:10.64898/2026.10.29.26366628
Sensor Validation and Digital Biomarker Exploration for Health Monitoring
Chou, E. F. S. (2023) · eScholarship (California Digital Library)
Metadata
- Authors
- Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O.
- Affiliations
- The University of Queensland (AU)
- Metro North Hospital and Health Service (AU)
- Corresponding author
- Hill, Andrew
- Venue
- Journal of Hypertension
- Published
- 2017-03
- Volume
- 35
- Issue
- 3
- Pages
- 421-441
- ISSN
- 0263-6352 (ISSN-L)
- PMC
- PMC5278896
- OpenAlex
- W2563521117
- Semantic Scholar
- 17b4fd73a6b155571b2a3a3aee7dbbd6bc78909a
- Cited by
- 357
- References
- 390
- Citations by year
- 2026: 34 · 2025: 46 · 2024: 45 · 2023: 45 · 2022: 45 · 2021: 46 · 2020: 41 · 2019: 28 · 2018: 21 · 2017: 6
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Journal of Hypertension (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Funders
- University of Queensland
- Metro North Hospital and Health Service
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- blood pressure measurement, measurement error, resting blood pressure, upper arm blood pressure, measurement variability, clinical deterioration, blood pressure monitoring, measurement error sources, blood pressure interpretation
- MeSH terms
- Alcohol Drinking, Arm, Urinary Bladder, Blood Pressure, Blood Pressure Determination, Caffeine, Cold Temperature, Eating, Humans, Hypertension, Nicotine, Rest, Reproducibility of Results, White Coat Hypertension, Tobacco Use
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.
