Sources of inaccuracy in the measurement of adult patients’ resting blood pressure in clinical settings: a systematic review
Open accessThe DOI matches its Crossref record; 386 of the 390 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
BACKGROUND: To interpret blood pressure (BP) data appropriately, healthcare providers need to be knowledgeable of the factors that can potentially impact the accuracy of BP measurement and contribute to variability between measurements. METHODS: A systematic review of studies quantifying BP measurement inaccuracy. Medline and CINAHL databases were searched for empirical articles and systematic reviews published up to June 2015. Empirical articles were included if they reported a study that was relevant to the measurement of adult patients' resting BP at the upper arm in a clinical setting (e.g. ward or office); identified a specific source of inaccuracy; and quantified its effect. Reference lists and reviews were searched for additional articles. RESULTS: A total of 328 empirical studies were included. They investigated 29 potential sources of inaccuracy, categorized as relating to the patient, device, procedure or observer. Significant directional effects were found for 27; however, for some, the effects were inconsistent in direction. Compared with true resting BP, significant effects of individual sources ranged from -23.6 to +33 mmHg SBP and -14 to +23 mmHg DBP. CONCLUSION: A single BP value outside the expected range should be interpreted with caution and not taken as a definitive indicator of clinical deterioration. Where a measurement is abnormally high or low, further measurements should be taken and averaged. Wherever possible, BP values should be recorded graphically within ranges. This may reduce the impact of sources of inaccuracy and reduce the scope for misinterpretations based on small, likely erroneous or misleading, changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“On a beat-to-beat basis, BP levels can vary markedly (from –24 mmHg to 33 mmHg) in response to usual extrinsic and behavioural factors4”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [4]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“the highly variable nature of office and out-of-office BP readings has been widely acknowledged”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [4]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Standardization is essential because there are many aspects of BP measurement, including the patient’s physical condition, clinic environment, and equipment that can readily result in inaccurate and unreliable values.23,25,26”
From International Consensus on Standardized Clinic Blood Pressure Measurement – A Call to Action (2023) · cites this paper as [25]
In the citing paper
“Even when a validated automated device is used, the accuracy of BP measurement may be influenced by many factors. 19 – 21”
From Hypertension Canada guideline for the diagnosis and treatment of hypertension in adults in primary care (2025) · cites this paper as [19]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
The Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220 · cited 1×
“Therefore, when interpreting the accuracy of a device, both the mean bias and the width of the limits of agreement should be considered [165,166].”
BackgroundPickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051 · cited 4×
“Generally, this change is assumed to involve an increase in both SBP and DBP from normal daytime values [4].”
BackgroundMethodInfluentialHuman blood pressure determination by sphygmomanometry.
Perloff, D., Grim, C., Flack, J., Frohlich, E. D., Hill, M., McDonald, M., & Morgenstern, B. Z. (1993) · Circulation · doi:10.1161/01.cir.88.5.2460 · Cited by 1,591
Williams, B., Poulter, N. R., Brown, M. J., Davis, M., McInnes, G. T., Potter, J. F., Sever, P. S., & McG Thom, S. (2004) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001683 · Cited by 1,272
Effects of Caffeine on Plasma Renin Activity, Catecholamines and Blood Pressure
Robertson, D., Frölich, J. C., Carr, R. K., Watson, J. T., Hollifield, J. W., Shand, D. G., & Oates, J. A. (1978) · New England Journal of Medicine · doi:10.1056/nejm197801262980403 · Cited by 757
Ambulatory blood pressure normality: results from the PAMELA study
Mancia, G., Sega, R., Bravi, C., Vito, G. D., Valagussa, F., Cesana, G., & Zanchetti, A. (1995) · Journal of Hypertension · doi:10.1097/00004872-199512000-00003 · Cited by 547
Practice parameters for hemodynamic support of sepsis in adult patients: 2004 update
Hollenberg, S. M., Ahrens, T. S., Annane, D., Astiz, M. E., Chalfin, D. B., Dasta, J. F., Heard, S. O., Martin, C., Napolitano, L. M., Susla, G. M., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000139761.05492.d6 · Cited by 521
Gao, H., McDonnell, A., Harrison, D. A., Moore, T., Adam, S., Daly, K., Esmonde, L., Goldhill, D. R., Parry, G. J., Rashidian, A., et al. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0532-3 · Cited by 466
Effect of Smoking on Arterial Stiffness and Pulse Pressure Amplification
Mahmud, A., & Feely, J. (2003) · Hypertension · doi:10.1161/01.hyp.0000047464.66901.60 · Cited by 436
Erratum to “Next Generation Sequencing: Potential and Application in Drug Discovery”
Yadav, N. K., Shukla, P., Omer, A., Pareek, S., Srivastava, A. K., Bansode, F. W., & Singh, R. K. (2014) · The Scientific World Journal · doi:10.1155/2014/621354 · Cited by 391
Coffee, caffeine and blood pressure: a critical review
Nurminen, M.-L., Niittynen, L., Korpela, R., & Vapaatalo, H. (1999) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600899 · Cited by 351
Mesas, A. E., Leon-Muñoz, L. M., Rodriguez-Artalejo, F., & Lopez-Garcia, E. (2011) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.111.016667 · Cited by 350
Ambulatory Blood Pressure: Normality and Comparison With Other Measurements
Schettini, C., Bianchi, M., Nieto, F., Sandoya, E., & Senra, H. (1999) · Hypertension · doi:10.1161/01.hyp.34.4.818 · Cited by 349
Review and performance evaluation of aggregate weighted ‘track and trigger’ systems
Smith, G. B., Prytherch, D. R., Schmidt, P. E., & Featherstone, P. I. (2008) · Resuscitation · doi:10.1016/j.resuscitation.2007.12.004 · Cited by 337
Persistent blood pressure increase induced by heavy smoking
Groppelli, A., Giorgi, D. M. A., Omboni, S., Parati, G., & Mancia, G. (1992) · Journal of Hypertension · doi:10.1097/00004872-199205000-00014 · Cited by 328
Astrup, A., Toubro, S., Cannon, S., Hein, P., Breum, L., & Madsen, J. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.5.759 · Cited by 309 · cited 1×
“Some small caffeine dosages, such as 100 and 200 mg, were not consistently reported to have a significant effect on BP [59,61].”
BackgroundShort and long-term effects of smoking on arterial wall properties in habitual smokers
Kool, M. J. F., Hoeks, A. P. G., Struijker Boudier, H. A. J., Reneman, R. S., & Van Bortel, L. M. A. B. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90773-t · Cited by 305
Validation of the Omron HEM-907 device for blood pressure measurement
El Assaad, M. A., Topouchian, J. A., Darné, B. M., & Asmar, R. G. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200208000-00006 · Cited by 279
Coleman, A., Steel, S., Freeman, P., de Greeff, A., & Shennan, A. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3282cb57b6 · Cited by 259
James, J. E. (2004) · Psychosomatic Medicine · doi:10.1097/10.psy.0000107884.78247.f9 · Cited by 232
(2006) · Pharmacology Biochemistry and Behavior · doi:10.1016/j.pbb.2006.03.005 · Cited by 213
White, W. B., & Anwar, Y. A. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200104000-00007 · Cited by 213
Influence of nicotine on cardiovascular and hormonal effects of cigarette smoking
Benowitz, N. L., Kuyt, F., & Jacob, P. (1984) · Clinical Pharmacology and Therapeutics · doi:10.1038/clpt.1984.142 · Cited by 212
White coat hypertension and white coat effect similarities and differences*
Verdecchia, P., Schillaci, G., Borgioni, C., Ciucci, A., Zampi, I., Gattobigio, R., Sacchi, N., & Porcellati, C. (1995) · American Journal of Hypertension · doi:10.1016/0895-7061(95)00151-e · Cited by 210
Does This Patient Have Hypertension? How to Measure Blood Pressure
Reeves, R. A. (1995) · JAMA · doi:10.1001/jama.273.15.1211 · Cited by 202
Sympathetic activity and blood pressure increases with bladder distension in humans.
Fagius, J., & Karhuvaara, S. (1989) · Hypertension · doi:10.1161/01.hyp.14.5.511 · Cited by 201
Acute Effect of Caffeine on Arterial Stiffness and Aortic Pressure Waveform
Mahmud, A., & Feely, J. (2001) · Hypertension · doi:10.1161/01.hyp.38.2.227 · Cited by 192
Coleman, A., Freeman, P., Steel, S., & Shennan, A. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000189788.05736.5f · Cited by 179
Inter-arm differences in blood pressure: when are they clinically significant?
Lane, D., Beevers, M., Barnes, N., Bourne, J., John, A., Malins, S., & Beevers, D. G. (2002) · Journal of Hypertension · doi:10.1097/00004872-200206000-00019 · Cited by 178
Religious Coping, Ethnicity, and Ambulatory Blood Pressure
Steffen, P. R., Hinderliter, A. L., Blumenthal, J. A., & Sherwood, A. (2001) · Psychosomatic Medicine · doi:10.1097/00006842-200107000-00002 · Cited by 177
Farsalinos, K. E., Tsiapras, D., Kyrzopoulos, S., Savvopoulou, M., & Voudris, V. (2014) · BMC Cardiovascular Disorders · doi:10.1186/1471-2261-14-78 · Cited by 172
Effects on blood pressure of drinking green and black tea
Hodgson, J. M., Puddey, I. B., Burke, V., Beilin, L. J., & Jordan, N. (1999) · Journal of Hypertension · doi:10.1097/00004872-199917040-00002 · Cited by 170
White, W. B., Lund-Johansen, P., & Omvik, P. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90026-w · Cited by 169
Ambulatory and Home Blood Pressure Normality in the Elderly: Data From the PAMELA Population
Sega, R., Cesana, G., Milesi, C., Grassi, G., Zanchetti, A., & Mancia, G. (1997) · Hypertension · doi:10.1161/01.hyp.30.1.1 · Cited by 167
Prevalence and clinical implications of the inter-arm blood pressure difference: a systematic review
Clark, C. E., Campbell, J., Evans, P. H., & Millward, A. (2006) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1002093 · Cited by 167
Effect of acute intake of red wine on flow-mediated vasodilatation of the brachial artery
Hashimoto, M., Kim, S., Eto, M., Iijima, K., Ako, J., Yoshizumi, M., Akishita, M., Kondo, K., Itakura, H., Hosoda, K., et al. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)02137-3 · Cited by 159
Blood Pressure Measurement Method and Inter-Arm Differences: A Meta-Analysis
Verberk, W. J., Kessels, A. G. H., & Thien, T. A. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2011.125 · Cited by 157
Measurement of blood presssure: an evidence based review
McAlister, F. A., & Straus, S. E. (2001) · BMJ · doi:10.1136/bmj.322.7291.908 · Cited by 154
Both body and arm position significantly influence blood pressure measurement
Netea, R. T., Lenders, J. W. M., Smits, P., & Thien, T. (2003) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001573 · Cited by 150
Lane, J. D., Adcock, R. A., Williams, R. B., & Kuhn, C. M. (1990) · Psychosomatic Medicine · doi:10.1097/00006842-199005000-00006 · Cited by 145
Cigarette smoking is associated with an acute impairment of microvascular function in humans.
IJzerman, R., Serné, E., van Weissenbruch, M. V., de Jongh, R. D., & Stehouwer, C. (2003) · Clinical science · doi:10.1042/cs20020318 · Cited by 139
Blood Pressure Measurement in Shock: Mechanism of Inaccuracy in Auscultatory and Palpatory Methods
Cohn, J. N. (1967) · JAMA · doi:10.1001/jama.1967.03120130058009 · Cited by 138
Kawahara, J., Sano, H., Fukuzaki, H., Saito, K., & Hiroucht, H. (1989) · American Journal of Hypertension · doi:10.1093/ajh/2.9.724 · Cited by 138
RHEE, M., NA, S., KIM, Y., LEE, M., & KIM, H. (2007) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2006.12.017 · Cited by 135
Grasser, E. K., Yepuri, G., Dulloo, A. G., & Montani, J.-P. (2014) · European Journal of Nutrition · doi:10.1007/s00394-014-0661-8 · Cited by 135
Are Aneroid Sphygmomanometers Accurate in Hospital and Clinic Settings?
Canzanello, V. J., Jensen, P. L., & Schwartz, G. L. (2001) · Archives of Internal Medicine · doi:10.1001/archinte.161.5.729 · Cited by 133
A review of common errors in the indirect measurement of blood pressure. Sphygmomanometry
Bailey, R. H. (1993) · Archives of Internal Medicine · doi:10.1001/archinte.153.24.2741 · Cited by 124
Cuckson, A. C., Reinders, A., Shabeeh, H., & Shennan, A. H. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200212000-00005 · Cited by 123
Anwar, Y., Giacco, McCabe, E. J., Tendler, B., & White, W. (1998) · PubMed · Cited by 120
Terminal digit preference, random error, and bias in routine clinical measurement of blood pressure
Wen, S. W., Kramer, M. S., Hoey, J., Hanley, J. A., & Usher, R. H. (1993) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(93)90118-k · Cited by 119
Rapid Response Team composition, resourcing and calling criteria in Australia
a (2011) · Resuscitation · doi:10.1016/j.resuscitation.2011.10.023 · Cited by 118
Acute depressor effect of alcohol in patients with essential hypertension.
Kawano, Y., Abe, H., Kojima, S., Ashida, T., Yoshida, K., Imanishi, M., Yoshimi, H., Kimura, G., Kuramochi, M., & Omae, T. (1992) · Hypertension · doi:10.1161/01.hyp.20.2.219 · Cited by 118
The effect of different body positions on blood pressure
Eşer, İ., Khorshid, L., Yapucu Güneş, Ü., & Demir, Y. (2007) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2005.01494.x · Cited by 117
Karatzis, E., Papaioannou, T. G., Aznaouridis, K., Karatzi, K., Stamatelopoulos, K., Zampelas, A., Papamichael, C., Lekakis, J., & Mavrikakis, M. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2003.11.013 · Cited by 116
Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive?
Araghi, A., Bander, J. J., & Guzman, J. A. (2006) · Critical Care · doi:10.1186/cc4896 · Cited by 115 · cited 1×
“Invasive, or intra-arterial, BP measurement through the use of a catheter is regarded as the gold standard of BP measurement [162,163].”
MethodValidation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor
Wright, J. M., Mattu, G. S., Perry, T. L., Gelferc, M. E., Strange, K. D., Zorn, A., & Chen, Y. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200106000-00008 · Cited by 115
Standardization of blood pressure measurement in an international comparative study
Ataman, S. L., Cooper, R., Rotimi, C. N., McGee, D., Osotimehin, B., Kadiri, S., Kingué, S., Muna, W. F. T., Fraser, H. S., Forrester, T., et al. (1996) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(96)00111-4 · Cited by 114
Acute and Chronic Effects of Smoking on Arterial Stiffness
Kubozono, T., Miyata, M., Ueyama, K., Hamasaki, S., Kusano, K., Kubozono, O., & Tei, C. (2010) · Circulation Journal · doi:10.1253/circj.cj-10-0552 · Cited by 112
How accurate are sphygmomanometers?
Mion, D., & Pierin, A. (1998) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000589 · Cited by 112
Acute Effects of Coffee on Endothelial Function in Healthy Subjects
Buscemi, S., Verga, S., Batsis, J. A., Donatelli, M., Tranchina, M. R., Belmonte, S., Mattina, A., Re, A., & Cerasola, G. (2010) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2010.9 · Cited by 110
Ostchega, Y., Prineas, R. J., Paulose‐Ram, R., Grim, C. M., Willard, G., & Collins, D. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00085-4 · Cited by 109
Prognostic Significance of Between-Arm Blood Pressure Differences
Agarwal, R., Bunaye, Z., & Bekele, D. M. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.104943 · Cited by 109
Ahuja, K., Robertson, I. K., & Ball, M. J. (2009) · American Journal of Clinical Nutrition · doi:10.3945/ajcn.2009.27771 · Cited by 108
Consistency of Blood Pressure Differences Between the Left and Right Arms
Eguchi, K. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.4.388 · Cited by 107
Renal and cardiovascular effects of caffeine: a dose-response study
Passmore, A. P., Kondowe, G. B., & Johnston, G. D. (1987) · Clinical Science · doi:10.1042/cs0720749 · Cited by 107
Ostchega, Y., Nwankwo, T., Sorlie, P. D., Wolz, M., & Zipf, G. (2010) · The Journal of Clinical Hypertension · doi:10.1111/j.1751-7176.2009.00199.x · Cited by 105
Mahmud, A., & Feely, J. (2004) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2003.01958.x · Cited by 103
Acute effects of tea on fasting and postprandial vascular function and blood pressure in humans
Hodgson, J. M., Burke, V., & Puddey, I. B. (2005) · Journal of Hypertension · doi:10.1097/00004872-200501000-00012 · Cited by 102
Grassi, G. M., Somers, V. K., Renk, W. S., Abboud, F. M., & Mark, A. L. (1989) · Journal of Hypertension · doi:10.1097/00004872-198900076-00007 · Cited by 100
Clark, C. E., Campbell, J., & Powell, R. J. (2007) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1002209 · Cited by 98
Acute effects of low doses of alcohol on left ventricular function by echocardiography.
Delgado, C. E., Gortuin, N. J., & Ross, R. S. (1975) · Circulation · doi:10.1161/01.cir.51.3.535 · Cited by 98
Influence of arm position on measurement of blood pressure.
Webster, J., Newnham, D., Petrie, J. C., & Lovell, H. G. (1984) · BMJ · doi:10.1136/bmj.288.6430.1574 · Cited by 98
Does it matter whether blood pressure measurements are taken with subjects sitting or supine?
Netea, R. T., Smits, P., Lenders, J. W. M., & Thien, T. (1998) · Journal of Hypertension · doi:10.1097/00004872-199816030-00002 · Cited by 98
Acute Effects of Passive Smoking on Peripheral Vascular Function
Argacha, J.-F., Adamopoulos, D., Gujic, M., Fontaine, D., Amyai, N., Berkenboom, G., & van de Borne, P. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.104059 · Cited by 98
Timing of Blood Pressure Measurement Related to Caffeine Consumption
Mort, J. R., & Kruse, H. R. (2008) · Annals of Pharmacotherapy · doi:10.1345/aph.1k337 · Cited by 98
Kimura, A., Hashimoto, J., Watabe, D., TAKAHASHI, H., Ohkubo, T., Kikuya, M., & Imai, Y. (2004) · Journal of Hypertension · doi:10.1097/00004872-200412000-00009 · Cited by 97
Ethnic differences in circadian hemodynamic profile.
Gretler, D. D., Fumo, M., Nelson, K., & Murphy, M. B. (1994) · American Journal of Hypertension · doi:10.1093/ajh/7.1.7 · Cited by 95
A systematic review of variability and reliability of manual and automated blood pressure readings
Skirton, H., Chamberlain, W., Lawson, C., Ryan, H., & Young, E. L. (2011) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2010.03528.x · Cited by 94
Hasenfratz, M., & Bättig, K. (1994) · Psychopharmacology · doi:10.1007/bf02244850 · Cited by 94
Blood pressure measurement in shock. Mechanism of inaccuracy in ausculatory and palpatory methods
Cohn, J. N. (1967) · JAMA · doi:10.1001/jama.199.13.118 · Cited by 94
Sphygmomanometers in hospital and family practice: problems and recommendations.
Burke, M. J., Towers, H. M., O'Malley, K., Fitzgerald, D. J., & O'Brien, E. T. (1982) · BMJ · doi:10.1136/bmj.285.6340.469 · Cited by 91
Divergent effect of acute and chronic alcohol on arterial stiffness
Mahmud, A. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02315-9 · Cited by 90
CASIGLIA, E., BONGIOVÌ, S., PALEARI, C. D., PETUCCO, S., BONI, M., COLANGELI, G., PENZO, M., & PESSINA, A. C. (1991) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1991.tb00385.x · Cited by 89
Relationship between daytime sleepiness and blood pressure in healthy older adults
GOLDSTEIN, I., ANCOLIISRAEL, S., & SHAPIRO, D. (2004) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2004.05.009 · Cited by 88
Acute Cardiovascular and Sympathetic Effects of Nicotine Replacement Therapy
Najem, B., Houssière, A., Pathak, A., Janssen, C., Lemogoum, D., Xhaët, O., Cuylits, N., & van de Borne, P. (2006) · Hypertension · doi:10.1161/01.hyp.0000219284.47970.34 · Cited by 88
Cicolini, G., Pizzi, C., Palma, E., Bucci, M., Schioppa, F., Mezzetti, A., & Manzoli, L. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2011.106 · Cited by 87
Effect of Terminal Digit Preference on Blood Pressure Measurement and Treatment in Primary Care
Nietert, P. J., Wessell, A. M., Feifer, C., & Ornstein, S. M. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.08.016 · Cited by 86
Acute cardiovascular effects of ethanol A controlled non-invasive study.
Kupari, M. (1983) · Heart · doi:10.1136/hrt.49.2.174 · Cited by 86
White coat effect and white coat hypertension in pediatric patients
Matsuoka, S., Kawamura, K., Honda, M., & Awazu, M. (2002) · Pediatric Nephrology · doi:10.1007/s00467-002-0990-3 · Cited by 85
Subjective and cardiovascular responses to nicotine combined with alcohol in male and female smokers
Perkins, K. A., Sexton, J. E., DiMarco, A., Grobe, J. E., Scierka, A. M., & Stiller, R. L. (1995) · Psychopharmacology · doi:10.1007/bf02246162 · Cited by 84
Ribezzo, S., Spina, E., Di Bartolomeo, S., & Sanson, G. (2014) · The Scientific World Journal · doi:10.1155/2014/353628 · Cited by 83
Mattu, G. S., Perry, T. L., & Wright, J. M. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200106000-00007 · Cited by 82
How Long Shall the Patient Rest Before Clinic Blood Pressure Measurement?
SALA, C., SANTIN, E., RESCALDANI, M., & MAGRINI, F. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.08.021 · Cited by 81
Shapiro, D., Goldstein, I. B., & Jamner, L. D. (1996) · Psychosomatic Medicine · doi:10.1097/00006842-199607000-00008 · Cited by 81
Caffeine Affects Cardiovascular Responses to Stress
Lane, J. D., & Williams, R. B. (1985) · Psychophysiology · doi:10.1111/j.1469-8986.1985.tb01662.x · Cited by 80
Effect of Back Support and Stethoscope Head on Seated Blood Pressure Determinations
Cushman, W. C., Cooper, K. M., Horne, R. A., & Meydrech, E. F. (1990) · American Journal of Hypertension · doi:10.1093/ajh/3.3.240 · Cited by 79
Caffeine-Induced Diuresis and Atrial Natriuretic Peptides
Nussberger, J., Mooser, V., Maridor, G., Juillerat, L., Waeber, B., & Brunner, H. R. (1990) · Journal of Cardiovascular Pharmacology · doi:10.1097/00005344-199005000-00001 · Cited by 79
Racial variation in cardiovascular morbidity and mortality in essential hypertension
Khattar, R. S., Swales, J. D., Senior, R., & Lahiri, A. (2000) · Heart · doi:10.1136/heart.83.3.267 · Cited by 79
Young, A. G. (1949) · The Lancet · doi:10.1016/s0140-6736(49)92094-2 · Cited by 78
Zhang, X., Zhang, S., Wang, C., Wang, B., & Guo, P. (2014) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph110302472 · Cited by 78
Cigar smoking has an acute detrimental effect on arterial stiffness
Vlachopoulos, C. (2004) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2003.12.014 · Cited by 76
Association of the Auscultatory Gap with Vascular Disease in Hypertensive Patients
Cavallini, M. C., Roman, M. J., Blank, S. G., Pini, R., Pickering, T. G., & Devereux, R. B. (1996) · Annals of Internal Medicine · doi:10.7326/0003-4819-124-10-199605150-00003 · Cited by 76
The inter-arm blood pressure difference and peripheral vascular disease: cross-sectional study
Clark, C. E., Campbell, J., Powell, R. J., & Thompson, J. F. (2007) · Family Practice · doi:10.1093/fampra/cmm035 · Cited by 75
Korhonen, I. (2006) · International Journal of Circumpolar Health · doi:10.3402/ijch.v65i2.18090 · Cited by 73
Manios, E., Vemmos, K., Tsivgoulis, G., Barlas, G., Eleni, K., Spengos, K., & Zakopoulos, N. (2007) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3280b083e2 · Cited by 72
Acute blood pressure elevations with caffeine in men with borderline systemic hypertension
Pincomb, G. A., Lovallo, W. R., McKey, B. S., Sung, B. H., Passey, R. B., Everson‐Rose, S. A., & Wilson, M. F. (1996) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)89392-7 · Cited by 70
Epidemiological Perspective of Body Position and Arm Level in Blood Pressure Measurement
Terént, A., & Breig-åsberg, E. (1994) · Blood Pressure · doi:10.3109/08037059409102246 · Cited by 70
Fonseca-Reyes, S., de Alba-García, J. G., Parra-Carrillo, J. Z., & Paczka-Zapata, J. A. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200306000-00002 · Cited by 69
A study of inter-arm blood pressure differences in primary care
Cassidy, P., & Jones, K. (2001) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001224 · Cited by 69
Presbyacusis—hearing thresholds and the ISO 7029
Stenklev, N. C., & Laukli, E. (2004) · International Journal of Audiology · doi:10.1080/14992020400050039 · Cited by 67
Hidden errors of aneroid sphygmomanometers
Waugh, J. J. S., Gupta, M., Rushbrook, J., Halligan, A., & Shennan, A. H. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200212000-00003 · Cited by 66
Blood pressure measurements are unreliable to diagnose hypertension in primary care
Sebo, P., Pechère-Bertschi, A., Herrmann, F. R., Haller, D. M., & Bovier, P. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000058 · Cited by 65
Hemodynamic and autonomic effects of smokeless tobacco in healthy young men
Wolk, R. A., Shamsuzzaman, A., Svatikova, A., Huyber, C., Huck, C. J., Narkiewicz, K., & Somers, V. K. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.11.056 · Cited by 65
Accuracy of the pressure scale of sphygmomanometers in clinical use within primary care
Coleman, A. J., Steel, S. D., Ashworth, M., Vowler, S. L., & Shennan, A. (2005) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000168398.87167.c2 · Cited by 64
Arm position and blood pressure: a risk factor for hypertension?
Mourad, A., Carney, S., Gillies, A. H. B., Jones, B. F., Nanra, R. S., & Trevillian, P. (2003) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001563 · Cited by 63
Ethnic differences in the hypertensive heart and 24-hour blood pressure profile.
Mayet, J., Chapman, N., Li, C., Shahi, M., Poulter, N., Sever, P. S., Foale, R. A., & Thom, S. (1998) · HYPERTENSION · doi:10.1161/01.hyp.31.5.1190 · Cited by 63
Cardiovascular Effects of Caffeine and Stress in Regular Coffee Drinkers
Lane, J. D., & Williams, R. B. (1987) · Psychophysiology · doi:10.1111/j.1469-8986.1987.tb00271.x · Cited by 63
Determining which automatic digital blood pressure device performs adequately: a systematic review
Wan, Y., Heneghan, C., Stevens, R., McManus, R. J., Ward, A., Perera, R., Thompson, M., Tarassenko, L., & Mant, D. (2010) · Journal of Human Hypertension · doi:10.1038/jhh.2010.37 · Cited by 63
Caffeine and Cardiovascular Responses to Stress
Lane, J. D. (1983) · Psychosomatic Medicine · doi:10.1097/00006842-198310000-00008 · Cited by 63
Effect of behavior state on caffeine's ability to alter blood pressure
Pincomb, G. A., Lovallo, W. R., Passey, R. B., & Wilson, M. F. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)91069-7 · Cited by 62
Sevransky, J., Nour, S., Susla, G. M., Needham, D. M., Hollenberg, S. M., & Pronovost, P. J. (2007) · Critical Care · doi:10.1186/cc5948 · Cited by 62
Terminal digit bias in a specialty hypertension faculty practice
Thavarajah, S., White, W. B., & Mansoor, G. A. (2003) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001625 · Cited by 62
The measuring of blood pressure during pregnancy
Villar, J., Repke, J. T., Markush, L., Calvert, W., & Rhoads, G. (1989) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(89)90777-1 · Cited by 61
Terminal Digit Preference in Blood Pressure Measurements: Effects on Epidemiological Associations
HESSEL, P. A. (1986) · International Journal of Epidemiology · doi:10.1093/ije/15.1.122 · Cited by 61
Accuracy of aneroid sphygmomanometers in clinical usage: University of Michigan experience
Yarows, S. A., & Qian, K. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200104000-00006 · Cited by 61
Central Aortic Blood Pressure of Hypertensive Men During Short-Term Cold Exposure
Hintsala, H. E., Kandelberg, A., Herzig, K., Rintamäki, H., Mäntysaari, M., Rantala, A. K., Antikaínen, R., Keinanen-Kiukaanniemi, S. M., Jaakkola, J. J. K., & Ikäheimo, T. M. (2013) · American Journal of Hypertension · doi:10.1093/ajh/hpt136 · Cited by 60
Practice audits: reliability of sphygmomanometers and blood pressure recording bias
Ali, S., & Rouse, A. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001384 · Cited by 60
The measurement of blood pressure: sitting or supine, once or twice?
Jamieson, M. J., Webster, J., Philips, S., Jeffers, T. A., SCOTT, A. K., Robb, O. J., Lovell, H. G., & Petrie, J. C. (1990) · Journal of Hypertension · doi:10.1097/00004872-199007000-00006 · Cited by 59
Type and accuracy of sphygmomanometers in primary care: a cross-sectional observational study
A'Court, C., Stevens, R., Sanders, S., Ward, A., McManus, R., & Heneghan, C. (2011) · British Journal of General Practice · doi:10.3399/bjgp11x593884 · Cited by 59
Additive Pressor Effects of Caffeine and Stress in Male Medical Students at Risk for Hypertension
Shepard, J. D., al'Absi, M., Whitsett, T. L., Passey, R. B., & Lovallo, W. R. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(99)00217-4 · Cited by 58
Wingfield, D., Cooke, J., Thijs, L., Staessen, J. A., Fletcher, A. E., Fagard, R., & Bulpitt, C. J. (2002) · Blood Pressure Monitoring · doi:10.1097/00126097-200206000-00005 · Cited by 58
The Effect of Cuff Size on Blood Pressure Measurement in Adults
Sprafka, J. M., Strickland, D., Gómez-Marín, O., & Prineas, R. J. (1991) · Epidemiology · doi:10.1097/00001648-199105000-00010 · Cited by 58
Ohte, N., Saeki, T., Miyabe, H., Sakata, S., Mukai, S., Hayano, J., Niki, K., Sugawara, M., & Kimura, G. (2007) · Heart and Vessels · doi:10.1007/s00380-007-0998-5 · Cited by 58
TACHIBANA, R., TABARA, Y., KONDO, I., MIKI, T., & KOHARA, K. (2004) · Hypertension Research · doi:10.1291/hypres.27.633 · Cited by 58
Optimum frequency of office blood pressure measurement using an automated sphygmomanometer
Myers, M. G., Valdivieso, M., & Kiss, A. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283104247 · Cited by 57
Aneroid sphygmomanometers. An assessment of accuracy at a university hospital and clinics
Bailey, R. H. (1991) · Archives of Internal Medicine · doi:10.1001/archinte.151.7.1409 · Cited by 57
Acute effects of passive smoking on blood pressure and heart rate in healthy females
Yarlioglues, M., Kaya, M. G., Ardic, I., Calapkorur, B., Dogdu, O., Akpek, M., Ozdogru, M., Kalay, N., Dogan, A., Ozdogru, I., et al. (2010) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e32833e439f · Cited by 56
Clinical decision-making in hypertension using an automated (BpTRU™) measurement device
Graves, J. W., Nash, C. A., Burger, K. N., Bailey, K. R., & Sheps, S. G. (2003) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001626 · Cited by 56
The effect of crossing legs on blood pressure: a randomized single-blind cross-over study
Peters, G. L., Binder, S. K., & Campbell, N. R. C. (1999) · Blood Pressure Monitoring · doi:10.1097/00126097-199900420-00007 · Cited by 55
Arnett, D. K., Tang, W., Province, M. A., Oberman, A., Ellison, R. C., Morgan, D., Eckfeldt, J. H., & Hunt, S. C. (2005) · Journal of Hypertension · doi:10.1097/01.hjh.0000170376.23461.f7 · Cited by 55
Effect of respiration, talking and small body movements on blood pressure measurement
Zheng, D., Giovannini, R., & Murray, A. (2011) · Journal of Human Hypertension · doi:10.1038/jhh.2011.53 · Cited by 55
Acute alcohol ingestion reduces heart rate variability
Weise, F., Krell, D., & Brinkhoff, N. (1986) · Drug and Alcohol Dependence · doi:10.1016/0376-8716(86)90040-2 · Cited by 55
Age-related differences in simultaneous interarm blood pressure measurements
Fotherby, M. D., Panayiotou, B., & Potter, J. F. (1993) · Postgraduate Medical Journal · doi:10.1136/pgmj.69.809.194 · Cited by 55
Caffeine increases aortic stiffness in hypertensive patients
Vlachopoulos, C. (2003) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)03155-2 · Cited by 55
Acute effects of cigarette smoking on insulin resistance and arterial stiffness in young adults
Seet, R. C. S., Loke, W. M., Khoo, C. M., Chew, S. E., Chong, W. L., Quek, A. M. L., Lim, E. C. H., & Halliwell, B. B. (2012) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2012.06.060 · Cited by 53
Assessment of the white-coat effect
Gerin, W., Ogedegbe, G., Schwartz, J. E., Chaplin, W. F., Goyal, T., Clemow, L., Davidson, K. W., Burg, M., Lipsky, S., Kentor, R., et al. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000194117.96979.13 · Cited by 53
Nikolic, S. B., Abhayaratna, W. P., Leano, R., Stowasser, M., & Sharman, J. E. (2013) · Journal of Human Hypertension · doi:10.1038/jhh.2013.38 · Cited by 53
Calibration accuracy of hospital-based non-invasive blood pressure measuring devices
de Greeff, A., Lorde, I., Wilton, A., Seed, P. T., Coleman, A. J., & Shennan, A. H. (2009) · Journal of Human Hypertension · doi:10.1038/jhh.2009.29 · Cited by 52
The Effect of Caffeine on Retrobulbar Hemodynamics
Özkan, B., Yüksel, N., Yonca Akgoz, A. N. I. K., Altıntaş, Ö., Demırcı, A., & Çağlar, Y. (2008) · Current Eye Research · doi:10.1080/02713680802344708 · Cited by 52
Selective recording in blood pressure readings may increase subsequent mortality
WINGFIELD, D. (2002) · QJM · doi:10.1093/qjmed/95.9.571 · Cited by 52
Stergiou, G. (2004) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2003.09.016 · Cited by 52
Methods for assessing blood pressure values in humans.
Mancia, G. (1983) · Hypertension · doi:10.1161/01.hyp.5.5_pt_2.iii5 · Cited by 52
Acute effects of cigarette smoking on left ventricular diastolic function
Kyriakides, Z. S., Kremastinos, D. T., Rentoukas, E. I., MAVROGHENI, S., KREMASTINOS, D. I., & Toutouzas, P. K. (1992) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060250 · Cited by 51
Home blood pressure normalcy: The Didima study
Stergiou, G. S., Thomopoulou, G. C., Skeva, I. I., & Mountokalakis, T. D. (2000) · American Journal of Hypertension · doi:10.1016/s0895-7061(99)00266-6 · Cited by 51
Pearce, K. A., Grimm, R. H., Rao, S., Svendsen, K., Liebson, P. R., Neaton, J. D., & Ensrud, K. E. (1992) · Archives of Internal Medicine · doi:10.1001/archinte.1992.00400160062012 · Cited by 51
Rabinowitz, B. D., Thorp, K., Huber, G. L., & Abelmann, W. H. (1979) · Circulation · doi:10.1161/01.cir.60.4.752 · Cited by 51
EFFECTS OF CAFFEINE ON PLASMA RENIN ACTIVITY, CATECHOLAMINES AND BLOOD PRESSURE
ROBERTSON, D., FR??LICH, J. C., CARR, R. K., WATSON, J. T., HOLLIFIELD, J. W., SHAND, D. G., & OATES, J. A. (1978) · Survey of Anesthesiology · doi:10.1097/00132586-197812000-00020 · Cited by 51
Ishikawa, J., Ishikawa, Y., Edmondson, D., Pickering, T. G., & Schwartz, J. E. (2011) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e328346d603 · Cited by 50
Sources of error in recording the blood pressure of patients with hypertension in general practice.
Patterson, H. R. (1984) · BMJ · doi:10.1136/bmj.289.6459.1661 · Cited by 50
The influence of cuff size on blood pressure measurement
Bakx, C., Oerlemans, G., van den Hoogen, H., van Weel, C., & Thien, T. A. (1997) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000470 · Cited by 50
Arm position is important for blood pressure measurement
Netea, R., Lenders, J., Smits, P., & Thien, T. B. (1999) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000720 · Cited by 49
Niiranen, T. J., Jula, A. M., Kantola, I. M., & Reunanen, A. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000239290.94764.81 · Cited by 49
Iwase, S., Matsukawa, T., Ishihara, S., Tanaka, A., Tanabe, K., Danbara, A., Matsuo, M., Sugiyama, Y., & Mano, T. (1995) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(95)00022-p · Cited by 49
Flouris, A. D., Metsios, G. S., Jamurtas, A. Z., & Koutedakis, Y. (2007) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00699.2007 · Cited by 49
Comparative Assessment of Four Blood Pressure Measurement Methods in Hypertensives
Lamarre-Cliché, M., Cheong, N. N., & Larochelle, P. M. (2011) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2011.05.001 · Cited by 48
Central and peripheral effects of sustained caffeine use: tolerance is incomplete
Watson, J., Deary, I., & Kerr, D. (2002) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2002.01681.x · Cited by 47
Prognostic Relevance of Masked Hypertension in Subjects With Prehypertension
Pierdomenico, S. D., Pannarale, G., Rabbia, F., Lapenna, D., Licitra, R., Zito, M., Campanella, M., Gaudio, C., Veglio, F., & Cuccurullo, F. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2008.196 · Cited by 47
Evaluating the Accuracy of an Aneroid Sphygmomanometer in a Clinical Trial Setting
Ma, Y., Temprosa, M., Fowler, S., Prineas, R. J., Montez, M. G., Brown-Friday, J., Carrion-Petersen, M. L., & Whittington, T. (2009) · American Journal of Hypertension · doi:10.1038/ajh.2008.338 · Cited by 46
de Lusignan, S., Belsey, J., Hague, N., & Dzregah, B. (2004) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001663 · Cited by 45
Characterization of the Korotkoff sounds using joint time–frequency analysis
Allen, J., Gehrke, T., O’Sullivan, J., King, S. T., & Murray, A. (2003) · Physiological Measurement · doi:10.1088/0967-3334/25/1/010 · Cited by 44
Myers, M. G., Harris, L., Leenen, F. H. H., & Grant, D. M. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90842-3 · Cited by 44
Influence of acute alcohol ingestion on sympathetic neural responses to orthostatic stress in humans
Carter, J. R., Stream, S. F., Durocher, J. J., & Larson, R. A. (2011) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00674.2010 · Cited by 44
Defects in sphygmomanometers: an important source of error in blood pressure recording.
Conceicao, S., Ward, M. K., & Kerr, D. N. S. (1976) · BMJ · doi:10.1136/bmj.1.6014.886 · Cited by 43
McDougle, C. J., Price, L. H., Heninger, G. R., Krystal, J. H., & Charney, D. S. (1995) · Psychopharmacology · doi:10.1007/bf02245830 · Cited by 43
Muscle sympathetic nerve activity during cold stress and isometric exercise in healthy older adults
Greaney, J. L., Stanhewicz, A. E., Kenney, W. L., & Alexander, L. M. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00516.2014 · Cited by 43
The effect of clothes on sphygmomanometric and oscillometric blood pressure measurement
Liebl, M. E., Holzgreve, H., Schulz, M., Crispin, A., & Bogner, J. R. (2004) · Blood Pressure · doi:10.1080/08037050410016465 · Cited by 42
Prolonged Increase in Blood Pressure by a Single Oral Dose of Caffeine in Mildly Hypertensive Men
Sung, B. H., Whitsett, T. L., Lovallo, W. R., al’Absi, M., Pincomb, G. A., & Wilson, M. F. (1994) · American Journal of Hypertension · doi:10.1093/ajh/7.8.755 · Cited by 42
The position of the arm during blood pressure measurement in sitting position
Adiyaman, A., Verhoeff, R., Lenders, J. W. M., Deinum, J., & Thien, T. A. (2006) · Blood Pressure Monitoring · doi:10.1097/01.mbp.0000218007.57957.56 · Cited by 41
Dickson, B. K., & Hajjar, I. M. (2007) · Journal of the American Academy of Nurse Practitioners · doi:10.1111/j.1745-7599.2006.00199.x · Cited by 40
Blood Pressure Monitoring Technique Impacts Hypertension Treatment
Ray, G. M., Nawarskas, J. J., & Anderson, J. R. (2011) · Journal of General Internal Medicine · doi:10.1007/s11606-011-1937-9 · Cited by 40
Jm, V. L., Peer, P. G. M., & Thien, T. A. (1986) · Journal of Hypertension · doi:10.1097/00004872-198610000-00017 · Cited by 40
The unsupported arm: a cause of falsely raised blood pressure readings.
Silverberg, D. S., Shemesh, E., & Iaina, A. (1977) · BMJ · doi:10.1136/bmj.2.6098.1331 · Cited by 40
Shaikh, R. B., Haque, N. M. A., Mohsen, H., Mohsen, A. A. H. K. A., Humadi, M. H. K., Mubarak, Z. Z. A., Mathew, E., & Sharbatti, S. A. (2012) · Asian Pacific Journal of Cancer Prevention · doi:10.7314/apjcp.2012.13.5.1819 · Cited by 40
Broad, J., Wells, S., Marshall, R., & Jackson, R. (2007) · British Journal of General Practice · doi:10.3399/096016407782317964 · Cited by 40
McManus, R. J., Mant, J., Hull, M. R. P., & Hobbs, R. F. (2003) · Europe PMC (PubMed Central) · Cited by 39
Accuracy of the Dinamap 1846 XT automated blood pressure monitor
Beaubien, E. R., Card, C. M., Card, S. E., Biem, H. J., & Wilson, T. W. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001463 · Cited by 39
Chang, J. J. (2003) · American Journal of Epidemiology · doi:10.1093/aje/kwg274 · Cited by 39
Inter‐arm blood pressure differences in pregnant women
Poon, L. C., Kametas, N. A., Strobl, I., Pachoumi, C., & Nicolaides, K. H. (2008) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2008.01756.x · Cited by 39
Schmieder, R. E., Schmidt, S. T., Riemer, T., Dechend, R., Hagedorn, I., Senges, J., Messerli, F. H., & Zeymer, U. (2014) · Hypertension · doi:10.1161/hypertensionaha.113.03140 · Cited by 39
ACHARYA, D., Heber, M. E., Doré, C. J., & Raftery, E. B. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(96)00177-x · Cited by 38
Observer error in blood pressure measurement.
Neufeld, P. D., & Johnson, D. L. (1986) · Europe PMC (PubMed Central) · Cited by 37
Acute effects of alcohol ingestion on blood pressure and erythrocyte sodium concentration
Kojima, S., Kawano, Y., Abe, H., Sanai, T., Yoshida, K., Imanishi, M., Ashida, T., Kimura, G., Yoshimi, H., Matsuoka, H., et al. (1993) · Journal of Hypertension · doi:10.1097/00004872-199302000-00011 · Cited by 37
The Normal Difference in Bilateral Indirect Blood Pressure Recordings in Hypertensive Individuals
Pesola, G. R., Pesola, H. R., Lin, M.-Y., Nelson, M. J., & Westfal, R. E. (2002) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2002.tb01333.x · Cited by 36
Hemodynamic Effects of Acute Caffeine Ingestion in Young Adults
Bender, A. M., Donnerstein, R. L., Samson, R. A., Zhu, D. C., & Goldberg, S. J. (1997) · The American Journal of Cardiology · doi:10.1016/s0002-9149(96)00848-x · Cited by 36
Ambulatory blood pressure of adults in Novosibirsk, Russia: interim report on a population study
Kuznetsova, T. (2001) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)01501-1 · Cited by 36
Cited by
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“The use of an inaccurate measurement technique is common, and a systematic review found a large bias associated with 27 of 29 potential sources of BP measurement error.(16) Table 1 lists key components of observer training for BP measurement.”
BackgroundMethodInfluentialCheung, A. K., Chang, T. I., Cushman, W. C., Furth, S. L., Hou, F. F., Ix, J. H., Knoll, G. A., Muntner, P., Pecoits-Filho, R., Sarnak, M. J., et al. (2021) · Kidney International · doi:10.1016/j.kint.2020.11.003 · Cited by 1,452
Nerenberg, K. A., Zarnke, K. B., Leung, A. A., Dasgupta, K., Butalia, S., McBrien, K., Harris, K. C., Nakhla, M., Cloutier, L., Gelfer, M., et al. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.02.022 · Cited by 573
Shimbo, D., Artinian, N. T., Basile, J. N., Krakoff, L. R., Margolis, K. L., Rakotz, M. K., Wozniak, G., & On behalf of the American Heart Association and the American Medical Association (2020) · Circulation · doi:10.1161/cir.0000000000000803 · Cited by 389
Metadata
- Authors
- Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O.
- Affiliations
- The University of Queensland (AU)
- Metro North Hospital and Health Service (AU)
- Corresponding author
- Hill, Andrew
- Venue
- Journal of Hypertension
- Published
- 2017-03
- Volume
- 35
- Issue
- 3
- Pages
- 421-441
- ISSN
- 0263-6352 (ISSN-L)
- PMC
- PMC5278896
- OpenAlex
- W2563521117
- Semantic Scholar
- 17b4fd73a6b155571b2a3a3aee7dbbd6bc78909a
- Cited by
- 357
- References
- 390
- Citations by year
- 2026: 34 · 2025: 46 · 2024: 45 · 2023: 45 · 2022: 45 · 2021: 46 · 2020: 41 · 2019: 28 · 2018: 21 · 2017: 6
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Journal of Hypertension (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Funders
- University of Queensland
- Metro North Hospital and Health Service
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- blood pressure measurement, measurement error, resting blood pressure, upper arm blood pressure, measurement variability, clinical deterioration, blood pressure monitoring, measurement error sources, blood pressure interpretation
- MeSH terms
- Alcohol Drinking, Arm, Urinary Bladder, Blood Pressure, Blood Pressure Determination, Caffeine, Cold Temperature, Eating, Humans, Hypertension, Nicotine, Rest, Reproducibility of Results, White Coat Hypertension, Tobacco Use
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.