Sources of inaccuracy in the measurement of adult patients’ resting blood pressure in clinical settings: a systematic review
Open accessThe DOI matches its Crossref record; 386 of the 390 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
BACKGROUND: To interpret blood pressure (BP) data appropriately, healthcare providers need to be knowledgeable of the factors that can potentially impact the accuracy of BP measurement and contribute to variability between measurements. METHODS: A systematic review of studies quantifying BP measurement inaccuracy. Medline and CINAHL databases were searched for empirical articles and systematic reviews published up to June 2015. Empirical articles were included if they reported a study that was relevant to the measurement of adult patients' resting BP at the upper arm in a clinical setting (e.g. ward or office); identified a specific source of inaccuracy; and quantified its effect. Reference lists and reviews were searched for additional articles. RESULTS: A total of 328 empirical studies were included. They investigated 29 potential sources of inaccuracy, categorized as relating to the patient, device, procedure or observer. Significant directional effects were found for 27; however, for some, the effects were inconsistent in direction. Compared with true resting BP, significant effects of individual sources ranged from -23.6 to +33 mmHg SBP and -14 to +23 mmHg DBP. CONCLUSION: A single BP value outside the expected range should be interpreted with caution and not taken as a definitive indicator of clinical deterioration. Where a measurement is abnormally high or low, further measurements should be taken and averaged. Wherever possible, BP values should be recorded graphically within ranges. This may reduce the impact of sources of inaccuracy and reduce the scope for misinterpretations based on small, likely erroneous or misleading, changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“On a beat-to-beat basis, BP levels can vary markedly (from –24 mmHg to 33 mmHg) in response to usual extrinsic and behavioural factors4”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [4]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“the highly variable nature of office and out-of-office BP readings has been widely acknowledged”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [4]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Standardization is essential because there are many aspects of BP measurement, including the patient’s physical condition, clinic environment, and equipment that can readily result in inaccurate and unreliable values.23,25,26”
From International Consensus on Standardized Clinic Blood Pressure Measurement – A Call to Action (2023) · cites this paper as [25]
In the citing paper
“Even when a validated automated device is used, the accuracy of BP measurement may be influenced by many factors. 19 – 21”
From Hypertension Canada guideline for the diagnosis and treatment of hypertension in adults in primary care (2025) · cites this paper as [19]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
The Surviving Sepsis Campaign Guidelines Committee including The Pediatric Subgroup*, Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2769-8 · Cited by 7,290
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220 · cited 1×
“Therefore, when interpreting the accuracy of a device, both the mean bias and the width of the limits of agreement should be considered [165,166].”
BackgroundPickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051 · cited 4×
“Generally, this change is assumed to involve an increase in both SBP and DBP from normal daytime values [4].”
BackgroundMethodInfluentialHuman blood pressure determination by sphygmomanometry.
Perloff, D., Grim, C., Flack, J., Frohlich, E. D., Hill, M., McDonald, M., & Morgenstern, B. Z. (1993) · Circulation · doi:10.1161/01.cir.88.5.2460 · Cited by 1,591
Williams, B., Poulter, N. R., Brown, M. J., Davis, M., McInnes, G. T., Potter, J. F., Sever, P. S., & McG Thom, S. (2004) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001683 · Cited by 1,272
Effects of Caffeine on Plasma Renin Activity, Catecholamines and Blood Pressure
Robertson, D., Frölich, J. C., Carr, R. K., Watson, J. T., Hollifield, J. W., Shand, D. G., & Oates, J. A. (1978) · New England Journal of Medicine · doi:10.1056/nejm197801262980403 · Cited by 757
Cited by
Mancia, G., Kreutz, R., Brunström, M., Burnier, M., Grassi, G., Januszewicz, A., Muiesan, M. L., Tsioufis, K., Agabiti-Rosei, E., Algharably, E. A. E., et al. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003480 · Cited by 3,473
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“The use of an inaccurate measurement technique is common, and a systematic review found a large bias associated with 27 of 29 potential sources of BP measurement error.(16) Table 1 lists key components of observer training for BP measurement.”
BackgroundMethodInfluentialCheung, A. K., Chang, T. I., Cushman, W. C., Furth, S. L., Hou, F. F., Ix, J. H., Knoll, G. A., Muntner, P., Pecoits-Filho, R., Sarnak, M. J., et al. (2021) · Kidney International · doi:10.1016/j.kint.2020.11.003 · Cited by 1,452
Nerenberg, K. A., Zarnke, K. B., Leung, A. A., Dasgupta, K., Butalia, S., McBrien, K., Harris, K. C., Nakhla, M., Cloutier, L., Gelfer, M., et al. (2018) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2018.02.022 · Cited by 573
Shimbo, D., Artinian, N. T., Basile, J. N., Krakoff, L. R., Margolis, K. L., Rakotz, M. K., Wozniak, G., & On behalf of the American Heart Association and the American Medical Association (2020) · Circulation · doi:10.1161/cir.0000000000000803 · Cited by 389
Blood pressure and its variability: classic and novel measurement techniques
Schutte, A. E., Kollias, A., & Stergiou, G. S. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00690-0 · Cited by 335
Writing Committee Members*, Jones, D. W., Ferdinand, K. C., Taler, S. J., Johnson, H. M., Shimbo, D., Abdalla, M., Altieri, M. M., Bansal, N., Bello, N. A., et al. (2025) · Hypertension · doi:10.1161/hyp.0000000000000249 · Cited by 310
Jones, D. W., Ferdinand, K. C., Taler, S. J., Johnson, H. M., Shimbo, D., Abdalla, M., Altieri, M. M., Bansal, N., Bello, N. A., Bress, A. P., et al. (2025) · JACC · doi:10.1016/j.jacc.2025.05.007 · Cited by 280
Drapkina, O. M., Васильевна, К. А., Калинина, А. М., Avdeev, S. M., Викторович, А. М., Alexandrova, L. M., Анциферова, А. А., Dm, A., Ахмеджанов, Н. М., Balanova, Y. А., et al. (2022) · CARDIOVASCULAR THERAPY AND PREVENTION · doi:10.15829/1728-8800-2022-3235 · Cited by 244
Writing Committee Members*, Jones, D. W., Ferdinand, K. C., Taler, S. J., Johnson, H. M., Shimbo, D., Abdalla, M., Altieri, M. M., Bansal, N., Bello, N. A., et al. (2025) · Circulation · doi:10.1161/cir.0000000000001356 · Cited by 213
Blood Pressure Assessment in Adults in Clinical Practice and Clinic-Based Research
Muntner, P., Einhorn, P. T., Cushman, W. C., Whelton, P. K., Bello, N. A., Drawz, P. E., Green, B. B., Jones, D. W., Juraschek, S. P., Margolis, K. L., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.069 · Cited by 199
“Increasingly, guidelines recommend use of validated upper-arm oscillometric devices in place of auscultation (25,45), which can reduce human error and bias, but does not eliminate many of the factors that contribute to inaccurate measurements and the need for trained observers (Table 3) (118).”
BackgroundPeixoto, A. J. (2019) · New England Journal of Medicine · doi:10.1056/nejmcp1901117 · Cited by 166
Kim, H.-L., Lee, E. M., Ahn, S. Y., Kim, K.-I., Kim, H. C., Kim, J. H., Lee, H.-Y., Lee, J. H., Park, J.-M., Cho, E. J., et al. (2023) · Clinical Hypertension · doi:10.1186/s40885-023-00234-9 · Cited by 164
Bress, A. P., Anderson, T. S., Flack, J. M., Ghazi, L., Hall, M. E., Laffer, C. L., Still, C. H., Taler, S. J., Zachrison, K. S., & Chang, T. I. (2024) · Hypertension · doi:10.1161/hyp.0000000000000238 · Cited by 155
Hypertension in Cancer Patients and Survivors
Cohen, J. B., Geara, A. S., Hogan, J. J., & Townsend, R. R. (2019) · JACC CardioOncology · doi:10.1016/j.jaccao.2019.11.009 · Cited by 150
Tribble, G. D., Angelov, N., Weltman, R., Wang, B.-Y., Eswaran, S. V., Gay, I. C., Parthasarathy, K., Dao, D.-H. V., Richardson, K. N., Ismail, N. M., et al. (2019) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2019.00039 · Cited by 118
Ishigami, J., Charleston, J., Miller, E. R., Matsushita, K., Appel, L. J., & Brady, T. M. (2023) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2023.3264 · Cited by 110
Padwal, R., Campbell, N. R. C., Schutte, A. E., Olsen, M. H., Delles, C., Etyang, A., Cruickshank, J. K., Stergiou, G., Rakotz, M. K., Wozniak, G., et al. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002112 · Cited by 108
“Multiple causes of inaccuracy exist and canbe categorized into patient-related, procedure-related, equipment-related, or observer-related (Table 3) [24].”
BackgroundRushton, A., Carlesso, L. C., Flynn, T. W., Hing, W. A., Rubinstein, S. M., Vogel, S. K., & Kerry, R. (2022) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.2022.11147 · Cited by 107
Saugel, B., Reese, P. C., Sessler, D. I., Burfeindt, C., Nicklas, J. Y., Pinnschmidt, H. O., Reuter, D. A., & Südfeld, S. (2019) · Anesthesiology · doi:10.1097/aln.0000000000002703 · Cited by 106
The Association between the Atherogenic Index of Plasma and Cardiometabolic Risk Factors: A Review
Lioy, B., Webb, R. J., & Amirabdollahian, F. (2023) · Healthcare · doi:10.3390/healthcare11070966 · Cited by 97
International Consensus on Standardized Clinic Blood Pressure Measurement – A Call to Action
Cheung, A. K., Whelton, P. K., Muntner, P., Schutte, A. E., Moran, A. E., Williams, B., Sarafidis, P., Chang, T. I., Daskalopoulou, S. S., Flack, J. M., et al. (2023) · The American Journal of Medicine · doi:10.1016/j.amjmed.2022.12.015 · Cited by 96
Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure
Sharman, J. E., Tan, I., Stergiou, G. S., Lombardi, C., Saladini, F., Butlin, M., Padwal, R., Asayama, K., Avolio, A., Brady, T. M., et al. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00693-x · Cited by 84
Nowak, D., Gośliński, M., & Nowatkowska, K. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15030544 · Cited by 80
Artificial Intelligence in Hypertension: Seeing Through a Glass Darkly
Padmanabhan, S., Tran, T. Q. B., & Dominiczak, A. F. (2021) · Circulation Research · doi:10.1161/circresaha.121.318106 · Cited by 78
Clinical practice guideline for the management of hypertension in China
Chinese Society of Cardiology, C. M. A., Hypertension Committee of Cross-Straits Medicine Exchange Association, & Cardiovascular Disease Prevention and Rehabilitation Committee, C. A. O. R. M. (2024) · Chinese Medical Journal · doi:10.1097/cm9.0000000000003431 · Cited by 68
Dodick, D. W., Tepper, S. J., Ailani, J., Pannacciulli, N., Navetta, M. S., Loop, B., Zhang, F., Khodavirdi, A. C., Mann, A., Abdrabboh, A., et al. (2021) · Headache The Journal of Head and Face Pain · doi:10.1111/head.14208 · Cited by 68
Kallioinen, N., Hill, A., Christofidis, M. J., Horswill, M. S., & Watson, M. (2020) · Journal of Advanced Nursing · doi:10.1111/jan.14584 · Cited by 62
Self-citationGoupil, R., Tsuyuki, R. T., Santesso, N., Terenzi, K. A., Habert, J., Cheng, G., Gysel, S. C., Bruneau, J., Leung, A. A., Campbell, N. R. C., et al. (2025) · Canadian Medical Association Journal · doi:10.1503/cmaj.241770 · Cited by 60
Variability independent of mean blood pressure as a real-world measure of cardiovascular risk
Ebinger, J. E., Driver, M. P., Ouyang, D., Botting, P. G., Ji, H., Rashid, M. A., Blyler, C. A., Bello, N. A., Rader, F., Niiranen, T., et al. (2022) · EClinicalMedicine · doi:10.1016/j.eclinm.2022.101442 · Cited by 60
Drawz, P. E., Beddhu, S., Bignall, O. N. R., Cohen, J. B., Flynn, J. T., Ku, E., Rahman, M., Thomas, G., Weir, M. R., & Whelton, P. K. (2022) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2021.09.013 · Cited by 59
Going Beyond the Guidelines in Individualising the Use of Antihypertensive Drugs in Older Patients
Scott, I. A., Hilmer, S. N., & Couteur, D. G. L. (2019) · Drugs & Aging · doi:10.1007/s40266-019-00683-8 · Cited by 56
Arm Position and Blood Pressure Readings: The ARMS Crossover Randomized Clinical Trial
Liu, H., Zhao, D., Sabit, A., Pathiravasan, C. H., Ishigami, J., Charleston, J., Miller, E. R., Matsushita, K., Appel, L. J., & Brady, T. M. (2024) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2024.5213 · Cited by 44
Alfian, S. D., van Boven, J. F. M., Abdulah, R., Sukandar, H., Denig, P., & Hak, E. (2020) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.14610 · Cited by 55
How to check whether a blood pressure monitor has been properly validated for accuracy
Picone, D. S., Padwal, R., Campbell, N. R. C., Boutouyrie, P., Brady, T. M., Olsen, M. H., Delles, C., Lombardi, C., Mahmud, A., Meng, Y., et al. (2020) · The Journal of Clinical Hypertension · doi:10.1111/jch.14065 · Cited by 52
Khan, N. A., Stergiou, G. S., Omboni, S., Kario, K., Renna, N. F., Chapman, N., McManus, R. J., Williams, B., Parati, G., Конради, А. О., et al. (2022) · Journal of Hypertension · doi:10.1097/hjh.0000000000003205 · Cited by 51
Kandzari, D. E., Townsend, R. R., Bakris, G. L., Basile, J., Bloch, M. J., Cohen, D. L., East, C. A., Ferdinand, K. C., Fisher, N. D. L., Kirtane, A. J., et al. (2021) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.29884 · Cited by 49
Blood Pressure Trajectories Across the Life Course
Allen, N. B., & Khan, S. S. (2021) · American Journal of Hypertension · doi:10.1093/ajh/hpab009 · Cited by 49
Green, B. B., Anderson, M. L., Cook, A. J., Ehrlich, K. J., Hall, Y. N., Hsu, C. W., Joseph, D., Klasnja, P., Margolis, K. L., McClure, J. B., et al. (2022) · Journal of General Internal Medicine · doi:10.1007/s11606-022-07400-z · Cited by 44
Assessment of Hypertension Using Clinical Electrocardiogram Features: A First-Ever Review
Bird, K., Chan, G., Lu, H. Y., Greeff, H., Allen, J., Abbott, D., Menon, C., Lovell, N. H., Howard, N., Chan, W., et al. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2020.583331 · Cited by 44
Cuff-based blood pressure measurement: challenges and solutions
Pilz, N., Picone, D. S., Patzak, A. R., Opatz, O. S., Lindner, T., Fesseler, L., Heinz, V., & Bothe, T. L. (2024) · Blood Pressure · doi:10.1080/08037051.2024.2402368 · Cited by 44
Kario, K., Williams, B., Tomitani, N., McManus, R. J., Schutte, A. E., Avolio, A. P., Shimbo, D., Wang, J., Khan, N. A., Picone, D. S., et al. (2024) · Journal of Hypertension · doi:10.1097/hjh.0000000000003827 · Cited by 43
Calibration of blood pressure measurements in the Jackson Heart Study
Seals, S. R., Colantonio, L. D., Tingle, J. V., Shimbo, D., Correa, A., Griswold, M. E., & Muntner, P. (2019) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000379 · Cited by 43
Effects of Different Rest Period Durations Prior to Blood Pressure Measurement: The Best Rest Trial
Brady, T. M., Charleston, J. B., Ishigami, J., Miller, E. R., Matsushita, K., & Appel, L. J. (2021) · Hypertension · doi:10.1161/hypertensionaha.121.17496 · Cited by 42
Michelsen, H. Ö., Sjölin, I., Bäck, M., García, M. G., Olsson, A., Sandberg, C., Șchiopu, A., & Leósdóttir, M. (2022) · Journal of Medical Internet Research · doi:10.2196/25224 · Cited by 40
Hill, A., Kelly, E., Horswill, M. S., & Watson, M. (2017) · Journal of Clinical Nursing · doi:10.1111/jocn.13861 · Cited by 40
Self-citationFoti, K. E., Wang, D., Chang, A. R., Selvin, E., Sarnak, M. J., Chang, T. I., Muntner, P., & Coresh, J. (2021) · Kidney International · doi:10.1016/j.kint.2020.12.019 · Cited by 39
Gąsecki, D., Coca, A., Cunha, P., Hering, D., Manios, E. D., Lović, D. B., Zaninelli, A., Sierra, C., Kwarciany, M., Narkiewicz, K., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001704 · Cited by 38
Lu, Y., Linderman, G. C., Mahajan, S., Liu, Y., Huang, C., Khera, R., Mortazavi, B. J., Spatz, E. S., & Krumholz, H. M. (2023) · Circulation Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.122.009258 · Cited by 38
Does This Adult Patient Have Hypertension? The Rational Clinical Examination Systematic Review
Viera, A. J., Yano, Y., Lin, F., Simel, D. L., Yun, J. J., Dave, G., Holle, A. F. V., Viera, L. A., Shimbo, D., Hardy, S. T., et al. (2021) · JAMA · doi:10.1001/jama.2021.4533 · Cited by 37
McGurgan, I. J., Kelly, P. J., Turan, T. N., & Rothwell, P. M. (2022) · Stroke · doi:10.1161/strokeaha.121.035851 · Cited by 36
Salomon, A., Ishaku, S., Kirk, K., & Warren, C. (2019) · BMC Health Services Research · doi:10.1186/s12913-019-4217-8 · Cited by 36
Cardiovascular risk profiles in a lupus cohort: what do different calculators tell us?
Boulos, D., Koelmeyer, R., Morand, E. F., & Hoi, A. Y.-B. (2017) · Lupus Science & Medicine · doi:10.1136/lupus-2017-000212 · Cited by 36
Bergholz, A., Meidert, A. S., Flick, M., Krause, L., Vettorazzi, E., Zapf, A., Brunkhorst, F. M., Meybohm, P., Zacharowski, K. D., Zarbock, A., et al. (2022) · Trials · doi:10.1186/s13063-022-06854-0 · Cited by 36
Blood Pressure measurements are site dependent in a cohort of patients with neurological illness
Siaron, K. B., Cortes, M. X., Stutzman, S. E., Venkatachalam, A. M., Ahmed, K. M., & Olson, D. M. (2020) · Scientific Reports · doi:10.1038/s41598-020-60414-7 · Cited by 35
Boonyasai, R. T., Carson, K. A., Marsteller, J. A., Dietz, K. B., Noronha, G. J., Hsu, Y., Flynn, S. J., Charleston, J. M., Prokopowicz, G. P., Miller, E. R., et al. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13166 · Cited by 34
Artificial intelligence-enhanced patient evaluation: bridging art and science
Oikonomou, E. K., & Khera, R. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehae415 · Cited by 34
A Survey on Blood Pressure Measurement Technologies: Addressing Potential Sources of Bias
Mousavi, S. S., Reyna, M. A., Clifford, G. D., & Sameni, R. (2024) · Sensors · doi:10.3390/s24061730 · Cited by 33
Cifras e impacto de la hipertensión arterial en España
Banegas, J. R., Sánchez-Martínez, M., Gijón‐Conde, T., López‐García, E., Graciani, A., Guallar‐Castillón, P., Puig, J. G., & Rodríguez‐Artalejo, F. (2024) · Revista Española de Cardiología · doi:10.1016/j.recesp.2024.03.002 · Cited by 32
Impact of Therapeutic Inertia on Long-Term Blood Pressure Control: A Monte Carlo Simulation Study
Augustin, A., Coutts, L. V., Zanisi, L., Wierzbicki, A. S., Shankar, F., Chowienczyk, P., & Floyd, C. N. (2021) · Hypertension · doi:10.1161/hypertensionaha.120.15866 · Cited by 32
Human Errors in Automated Office Blood Pressure Measurement: Still Room for Improvement
Elias, M. F., & Goodell, A. L. (2021) · Hypertension · doi:10.1161/hypertensionaha.120.16164 · Cited by 31
The Effect Of Home-Based Hypertension Screening On Blood Pressure Change Over Time In South Africa
Sudharsanan, N., Chen, S., Garber, M. D., Bärnighausen, T., & Geldsetzer, P. (2020) · Health Affairs · doi:10.1377/hlthaff.2019.00585 · Cited by 31
Sakhuja, S., Jaeger, B. C., Akinyelure, O. P., Bress, A. P., Shimbo, D., Schwartz, J. E., Hardy, S. T., Howard, G., Drawz, P., & Muntner, P. (2022) · The Journal of Clinical Hypertension · doi:10.1111/jch.14418 · Cited by 28
Nowak, D., Gośliński, M., Wesołowska, A., Berenda, K., & Popławski, C. (2019) · Evidence-based Complementary and Alternative Medicine · doi:10.1155/2019/6076751 · Cited by 28
Peprah, Y. A., Lee, J. Y., & Persell, S. D. (2023) · Journal of Human Hypertension · doi:10.1038/s41371-022-00795-6 · Cited by 27
Campbell, N. R. C., Padwal, R. S., Picone, D. S., Su, H., & Sharman, J. E. (2020) · Journal of Clinical Hypertension · doi:10.1111/jch.13915 · Cited by 27
Physician Medical Assessment in a Multidisciplinary Concussion Clinic
Zasler, N. D., Haider, M. N., Grzibowski, N. R., & Leddy, J. J. (2019) · Journal of Head Trauma Rehabilitation · doi:10.1097/htr.0000000000000524 · Cited by 27
Todkar, S., Padwal, R. S., Michaud, A., & Cloutier, L. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002663 · Cited by 27
Self-Measured Blood Pressure Telemonitoring Programs: A Pragmatic How-to Guide
McGrath, D., Meador, M., Wall, H. K., & Padwal, R. S. (2023) · American Journal of Hypertension · doi:10.1093/ajh/hpad040 · Cited by 26
Clinical Implementation of Self-Measured Blood Pressure Monitoring, 2015–2016
Jackson, S. L., Ayala, C., Tong, X., & Wall, H. K. (2018) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2018.06.017 · Cited by 26
Campbell, N. R. C., Khalsa, T., Ordunez, P., Rodriguez Morales, Y. A., Zhang, X., Parati, G., Padwal, R., Tsuyuki, R. T., Cloutier, L., & Sharman, J. E. (2020) · The Journal of Clinical Hypertension · doi:10.1111/jch.14017 · Cited by 25
Sheppard, J. P., Martin, U., Gill, P. S., Stevens, R., Hobbs, R. F., Mant, J., Godwin, M. S., Hanley, J., McKinstry, B., Myers, M. G., et al. (2018) · BMJ · doi:10.1136/bmj.k2478 · Cited by 25
G. Celler, B., Butlin, M., Argha, A., Tan, I., Yong, A., & Avolio, A. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3079578 · Cited by 24
Update on Hypertension Research in 2021
Mogi, M., Maruhashi, T., Higashi, Y., Masuda, T., Nagata, D., Nagai, M., Bokuda, K., Ichihara, A., Nozato, Y., Toba, A., et al. (2022) · Hypertension Research · doi:10.1038/s41440-022-00967-4 · Cited by 24
Prevalence of postprandial hypotension in older adults: a systematic review and meta-analysis
Huang, L., Li, S., Xie, X., Huang, X., Xiao, L. D., Zou, Y. K., Jiang, W., & Zhang, F. (2024) · Age and Ageing · doi:10.1093/ageing/afae022 · Cited by 24
Hayer, R., Kirley, K., Cohen, J. B., Tsipas, S., Sutherland, S. E., Oparil, S., Shay, C. M., Cohen, D. L., Kabir, C., & Wozniak, G. (2022) · Journal of Clinical Hypertension · doi:10.1111/jch.14419 · Cited by 24
Multiparametric cloth-based wearable, SimpleSense, estimates blood pressure
Kumar, P. S., Rai, P., Ramasamy, M., Varadan, V., & Varadan, V. K. (2022) · Scientific Reports · doi:10.1038/s41598-022-17223-x · Cited by 24
How to find and use validated blood pressure measuring devices
Picone, D. S., Padwal, R. S., Stergiou, G. S., Cohen, J. B., McManus, R. J., Eckert, S., Asayama, K., Atkins, N., Rakotz, M., Lombardi, C., et al. (2022) · Journal of Human Hypertension · doi:10.1038/s41371-022-00718-5 · Cited by 24
Keating, S. E., Barnett, A., Croci, I., Hannigan, A., Elvin‐Walsh, L., Coombes, J. S., Campbell, K. L., Macdonald, G. A., & Hickman, I. J. (2020) · Archives of Rehabilitation Research and Clinical Translation · doi:10.1016/j.arrct.2020.100066 · Cited by 23
Green, B. B., Anderson, M. L., Ehrlich, K. J., Hall, Y. N., Hansell, L. D., Hsu, C. W., Joseph, D., Margolis, K. L., McClure, J. B., Munson, S. A., et al. (2022) · The Journal of the American Board of Family Medicine · doi:10.3122/jabfm.2022.02.210318 · Cited by 23
Seguret, D., Gamelon, D., Dourmap, C., & Steichen, O. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002460 · Cited by 23
Numerical values and impact of hypertension in Spain
Banegas, J. R., Sánchez-Martínez, M., Gijón‐Conde, T., López‐García, E., Graciani, A., Guallar‐Castillón, P., Puig, J. G., & Rodríguez‐Artalejo, F. (2024) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2024.03.011 · Cited by 22
Caetano, G. M., Daniel, A. C. Q. G., Costa, B. C. P., & Veiga, E. V. (2021) · Texto & Contexto - Enfermagem · doi:10.1590/1980-265x-tce-2020-0237 · Cited by 22
Brady, T. M., Padwal, R. S., Blakeman, D. E., Farrell, M., Frieden, T. R., Kaur, P., Moran, A. E., & Jaffe, M. G. (2020) · Journal of Clinical Hypertension · doi:10.1111/jch.13867 · Cited by 22
Li, Y., Li, F., Li, Y., Cui, X., Li, J., Zhi, H., Wang, W., Sun, Y., & Cui, W. (2020) · Journal of Clinical Hypertension · doi:10.1111/jch.13902 · Cited by 21
Parker, R. A., Paterson, M., Padfield, P. L., Pinnock, H., Hanley, J., Hammersley, V., Steventon, A., & McKinstry, B. (2018) · BMJ Open · doi:10.1136/bmjopen-2017-019431 · Cited by 21
Polygenic risk scores associate with blood pressure traits across the lifespan
Øvretveit, K., Ingeström, E., Spitieris, M., Tragante, V., Wade, K. H., Thomas, L. F., Wolford, B. N., Wisløff, U., Gudbjartsson, D. F., Hólm, H., et al. (2023) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwad365 · Cited by 21
Saherwala, A. A., Stutzman, S. E., Osman, M., Kalia, J. S., Figueroa, S. A., Olson, D. M., & Aiyagari, V. (2018) · Neurocritical Care · doi:10.1007/s12028-018-0521-0 · Cited by 21
Effects of Noise and Public Setting on Blood Pressure Readings: A Randomized Crossover Trial
Ishigami, J., Liu, H., Zhao, D., Sabit, A. H., Pathiravasan, C. H., Charleston, J. B., Miller, E. R., Matsushita, K., Appel, L. J., & Brady, T. M. (2025) · Annals of Internal Medicine · doi:10.7326/annals-24-00873 · Cited by 21
The Role of a Smart Health Ecosystem in Transforming the Management of Chronic Health Conditions
Nourse, R. A., Dingler, T., Kelly, J. T., Kwaśnicka, D., & Maddison, R. (2023) · Journal of Medical Internet Research · doi:10.2196/44265 · Cited by 20
Menghini, L., & Balducci, C. (2024) · Journal of Occupational Health Psychology · doi:10.1037/ocp0000383 · Cited by 20
Impact of sleep quality and physical activity on blood pressure variability
de Havenon, A., Falcone, G. J., Rivier, C. A., Littig, L., Petersen, N., de Villèle, P., Prabhakaran, S., Kimberly, W. T., Mistry, E. A., & Sheth, K. N. (2024) · PLoS ONE · doi:10.1371/journal.pone.0301631 · Cited by 20
Tang, O., Juraschek, S. P., Appel, L. J., Cooper, L. A., Charleston, J. B., Boonyasai, R. T., Carson, K. A., Yeh, H., & Miller, E. R. (2018) · Journal of Clinical Hypertension · doi:10.1111/jch.13412 · Cited by 19
Bothe, T. L., Kreutz, R. H., Glos, M., Patzak, A. R., & Pilz, N. (2023) · Journal of Hypertension · doi:10.1097/hjh.0000000000003632 · Cited by 19
The Accuracy in Measurement of Blood Pressure (AIM‐BP) collaborative: Background and rationale
Padwal, R. S., Campbell, N. R. C., Weber, M. A., Lackland, D. T., Shimbo, D., Zhang, X., Schutte, A. E., Rakotz, M., Wozniak, G., Townsend, R. R., et al. (2019) · Journal of Clinical Hypertension · doi:10.1111/jch.13735 · Cited by 18
Miazgowski, T., Miazgowski, B., Kaczmarkiewicz, A., & Kopec, J. A. (2021) · Archives of Endocrinology and Metabolism · doi:10.20945/2359-3997000000333 · Cited by 18
Poon, S. J., Roumie, C. L., O'Shea, C. J., Fabbri, D., Coco, J., Collins, S. P., Levy, P. D., & McNaughton, C. D. (2020) · Journal of the American Heart Association · doi:10.1161/jaha.119.015985 · Cited by 18
Fu, S. N., Dao, M. C., Wong, C. K. H., & Cheung, B. M. Y. (2022) · Postgraduate Medical Journal · doi:10.1136/postgradmedj-2020-139329 · Cited by 18
Zhang, L., Liang, H., Luo, H., He, W., Cai, Y., Liu, S., Fan, Y., Huang, W., Zhao, Q., Zhong, D., et al. (2023) · The Lancet Regional Health - Western Pacific · doi:10.1016/j.lanwpc.2023.100973 · Cited by 17
Lee, W. L., Danaee, M., Abdullah, A. B., & Wong, L. P. (2023) · Cardiology Research · doi:10.14740/cr1569 · Cited by 17
Metadata
- Authors
- Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O.
- Affiliations
- The University of Queensland (AU)
- Metro North Hospital and Health Service (AU)
- Corresponding author
- Hill, Andrew
- Venue
- Journal of Hypertension
- Published
- 2017-03
- Volume
- 35
- Issue
- 3
- Pages
- 421-441
- ISSN
- 0263-6352 (ISSN-L)
- PMC
- PMC5278896
- OpenAlex
- W2563521117
- Semantic Scholar
- 17b4fd73a6b155571b2a3a3aee7dbbd6bc78909a
- Cited by
- 357
- References
- 390
- Citations by year
- 2026: 34 · 2025: 46 · 2024: 45 · 2023: 45 · 2022: 45 · 2021: 46 · 2020: 41 · 2019: 28 · 2018: 21 · 2017: 6
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Journal of Hypertension (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Funders
- University of Queensland
- Metro North Hospital and Health Service
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- blood pressure measurement, measurement error, resting blood pressure, upper arm blood pressure, measurement variability, clinical deterioration, blood pressure monitoring, measurement error sources, blood pressure interpretation
- MeSH terms
- Alcohol Drinking, Arm, Urinary Bladder, Blood Pressure, Blood Pressure Determination, Caffeine, Cold Temperature, Eating, Humans, Hypertension, Nicotine, Rest, Reproducibility of Results, White Coat Hypertension, Tobacco Use
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.
