Lancet Commission on Hypertension group position statement on the global improvement of accuracy standards for devices that measure blood pressure
Open accessThe DOI matches its Crossref record; 57 of the 58 references it cites were found in a registry or an index.
Abstract
: The Lancet Commission on Hypertension identified that a key action to address the worldwide burden of high blood pressure (BP) was to improve the quality of BP measurements by using BP devices that have been validated for accuracy. Currently, there are over 3000 commercially available BP devices, but many do not have published data on accuracy testing according to established scientific standards. This problem is enabled through weak or absent regulations that allow clearance of devices for commercial use without formal validation. In addition, new BP technologies have emerged (e.g. cuffless sensors) for which there is no scientific consensus regarding BP measurement accuracy standards. Altogether, these issues contribute to the widespread availability of clinic and home BP devices with limited or uncertain accuracy, leading to inappropriate hypertension diagnosis, management and drug treatment on a global scale. The most significant problems relating to the accuracy of BP devices can be resolved by the regulatory requirement for mandatory independent validation of BP devices according to the universally-accepted International Organisation for Standardization Standard. This is a primary recommendation for which there is an urgent international need. Other key recommendations are development of validation standards specifically for new BP technologies and online lists of accurate devices that are accessible to consumers and health professionals. Recommendations are aligned with WHO policies on medical devices and universal healthcare. Adherence to recommendations would increase the global availability of accurate BP devices and result in better diagnosis and treatment of hypertension, thus decreasing the worldwide burden from high BP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“hundreds of companies manufacturing more than 3500 different models of automated BPMDs, many of which are without evidence of having passed validation testing [25–29].”
From Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure (2022) · cites this paper as [29]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The lack of standardization in BP measurement is a serious and frequent problem in contemporary clinical practice that impacts patient safety and health system performance.8”
From International Consensus on Standardized Clinic Blood Pressure Measurement – A Call to Action (2023) · cites this paper as [8]
The cited source says what the claim attributes to it.
In the citing paper
“To date, no regulatory requirements exist for independent validation of all BP devices that are put on the market (using the universally accepted International Organization for Standardization (ISO) standard), despite increasing calls to mandate validation of these devices16.”
From Blood pressure and its variability: classic and novel measurement techniques (2022) · cites this paper as [16]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Ettehad, D., Emdin, C. A., Kiran, A., Anderson, S. G., Callender, T., Emberson, J., Chalmers, J., Rodgers, A., & Rahimi, K. (2016) · The Lancet · doi:10.1016/s0140-6736(15)01225-8 · Cited by 3,755 · cited 1×
“Reassuringly, if the presence of high BP can be correctly identified with appropriate use of accurate BP devices and BP measurement protocols, the risk of future cardiovascular events can be reduced significantly with BP-lowering medications [4], dietary and lifestyle interventions [5].”
BackgroundSelf-citationWilliams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
Self-citationGakidou, E., Afshin, A., Abajobir, A. A., Abate, K. H., Abbafati, C., Abbas, K. M., Abd-Allah, F., Abdulle, A. M., Abera, S. F., Aboyans, V., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32366-8 · Cited by 2,406 · cited 1×
“H igh blood pressure (BP) is the leading modifiable risk factor for cardiovascular disease, contributing to the greatest global burden of disease [1,2].”
BackgroundPickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051 · cited 2×
“Thus, accurate BP measurement has been cited as one of the most important tests in clinical medicine [10].”
BackgroundChow, C. K. (2013) · JAMA · doi:10.1001/jama.2013.184182 · Cited by 1,991 · cited 1×
“There are major deficiencies with respect to optimal awareness, diagnosis and treatment of high BP, and these problems persist across low-income, middle-income and highincome countries, altogether emphasizing the need for widespread population-level improvement [3].”
BackgroundSelf-citationWhelton, P. K. (2002) · JAMA · doi:10.1001/jama.288.15.1882 · Cited by 1,473 · cited 1×
“Reassuringly, if the presence of high BP can be correctly identified with appropriate use of accurate BP devices and BP measurement protocols, the risk of future cardiovascular events can be reduced significantly with BP-lowering medications [4], dietary and lifestyle interventions [5].”
BackgroundVlachopoulos, C., Aznaouridis, K., O'Rourke, M. F., Safar, M. E., Baou, K., & Stefanadis, C. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq024 · Cited by 1,363
Olsen, M. H., Angell, S. Y., Asma, S., Boutouyrie, P., Burger, D., Chirinos, J. A., Damasceno, A., Delles, C., Gimenez-Roqueplo, A.-P., Hering, D., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31134-5 · Cited by 939 · cited 1×
“One of the key actions of The Lancet Commission on Hypertension was to improve BP evaluation from better quality of BP measurements through endorsed protocols and validated (accurate) BP monitors [11].”
BackgroundSelf-citationToward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
Research works printed but not linked: 1
- AMA. AHA developing list of validated BP monitors. https://wire.ama-assn.org/delivering-care/ama-aha-developing-list-validated-bp-monitors [Accessed 15 August 2018].
Cited by
Items 101–151 of 151
The Impact of Lifestyle Factors on Arterial Blood Pressure and Its Control in Hypertensive Patients
Elfituri, Z. Y. K., Dardar, H., Alshibani, Y., Koubas, A., Aboukanda, E. K., & Suaiee, A. (2025) · Razi Medical Journal · doi:10.69667/rmj.25203 · Cited by 2
Cohen, J. B., & Townsend, R. R. (2020) · Nephrology Self-Assessment Program · doi:10.1681/nsap.2020.19.1.2 · Cited by 2
Self-citationPadwal, R. S., Wood, P. W., McLean, D., & Ringrose, J. (2020) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000454 · Cited by 2
Self-citationVischer, A. S., Dutilh, G., Socrates, T., & Burkard, T. (2022) · Journal of Clinical Hypertension · doi:10.1111/jch.14474 · Cited by 2
A Circuit Design of a Sensor Amplifier for Improving Blood Pressure Measurement in Telehealth System
Panergo, M. C., Cruz, F. R. G., & Maaliw, R. R., III (2021) · IEEE Annual Information Technology, Electronics and Mobile Communication Conference (IEMCON) · doi:10.1109/iemcon53756.2021.9623070 · Cited by 2
Desson, Z., Sharman, J. E., Searles, A., Schutte, A. E., Delles, C., Olsen, M. H., Ordúñez, P., Hure, A. J., Morton, R. L., Figtree, E., et al. (2023) · Journal of Human Hypertension · doi:10.1038/s41371-023-00866-2 · Cited by 2
“In 2019, the Lancet Commission on Hypertension Group outlined a series of recommended actions to increase the global availability of appropriately validated BPMDs [15].”
BackgroundSelf-citationAnalysis of Hypertention Prevention Behavior Based on Health Belief Model at Pulau Nasi, Pulo Aceh
Ricinta, P. A., Fahdhienie, F., & Ariscasari, P. (2024) · Media Publikasi Promosi Kesehatan Indonesia (MPPKI) · doi:10.56338/mppki.v7i8.5952 · Cited by 1
Karna, P. K., & Jain, P. J. (2024) · A Bi-annual south Asian journal of research and innovation. · doi:10.3126/jori.v11i1-2.77853 · Cited by 1
“It leads to uneven equipment performance and possible risks to patient safety (Sharman et al., 2020.”
Chavez‐Ecos, F. A., Chávez-Malpartida, S. S., Parra-Huaroto, A. M., Chavez-Ecos, R., Camacho-Caballero, K., Chavez-Ecos, M. S., Chavez-Gutarra, M. A., Hernández, H. A., & Toro-Huamanchumo, C. J. (2025) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000769 · Cited by 1
Li, Q., Dong, J., Jiang, H., Sun, Y., Zhai, J., Xue, Y., Liu, M., Shen, F., Qiu, Y., Xie, J., et al. (2025) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000774 · Cited by 1
Tehrani, F. R., Firouzi, F., Farrokhi, R., Naz, M. S. G., Mousavi, M., Azizi, F., & Behboudi‐Gandevani, S. (2025) · Health Science Reports · doi:10.1002/hsr2.71325 · Cited by 1
Hypertensive retinopathy: The need for a change in perspective
Shukla, D., Dhawan, A., & Kalliath, J. (2025) · Indian Journal of Ophthalmology · doi:10.4103/ijo.ijo_1517_25 · Cited by 1
“[12] Further, the inherent variability of BP per se ( white‑coat and masked HT) [13] and variable training of paramedical staff (who mostly check BP for physicians) have confounded the diagnostic dilemma, masking the silent killer further.”
Gong, M., Yu, Y., Chen, Y., Li, J., Su, J., Huang, Y., Zhong, K., ZHANG, 张. J., Yuta, T., Zhang, Y., et al. (2026) · Blood Pressure · doi:10.1080/08037051.2026.2682038 · Cited by 1
Ringrose, J., & Sridar, S. (2020) · Journal of Clinical Hypertension · doi:10.1111/jch.13900 · Cited by 1
Auscl-D: a mercury-free digital auscultatory sphygmomanometer
Kumar, V., Kumar, R., Kumar, M., Wander, G. S., & Sahani, A. K. (2021) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2021.1946182 · Cited by 1
Comment mesurer la pression artérielle en 2022 ? Quelle mesure pour quel patient ?
Asmar, R. G. (2022) · Archives des Maladies du Coeur et des Vaisseaux - Pratique · doi:10.1016/j.amcp.2022.01.002 · Cited by 1
Self-citationHypertension Care During Emergencies and Pandemics
Samuel, J. P., & Hyman, B. K. (2023) · Springer eBooks · doi:10.1007/978-3-031-06231-5_63 · Cited by 1
Validation Status of Electronic Sphygmomanometers in China: A National Survey
Zhang, X., Xu, Z., Yao, Y., Zheng, H., Wu, J., Hu, J., Wu, S., Lyu, Q., Liu, Y., Wu, M., et al. (2025) · Hypertension · doi:10.1161/hypertensionaha.124.24203 · Cited by 1
“29,30 In addition, to improve accuracy standards, policy measures such as accredited online registries for validated devices, stricter sales regulations, and ensuring equitable and affordable access to validated devices have also been proposed.”
Antza, C., Sitmalidou, M., Belančić, A., Katsiki, N., & Kotsis, V. (2025) · Medicina · doi:10.3390/medicina61030434 · Cited by 1
“Three different types of BP monitoring (i.e., OBPM, HBPM, and 24h-ABPM) were performed in all participants, following the European Society of Hypertension (ESH) guidelines [6] and using validated devices [17].”
The Rapid Evolution of Continuous Blood Pressure Measurement: Future Considerations
Casey, D. E., Wozniak, G., Ma, S., Kati, S., & Elms, A. M. (2025) · American Journal of Hypertension · doi:10.1093/ajh/hpaf101 · Cited by 1
Self-citationPerspectives of Global Standards on Validation of Blood Pressure Measuring Devices
Fang, J., Ji, N., Deng, M., Du, C., Xiang, T., Liu, Z., Zhang, Y., & Pan, T. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3587411 · Cited by 1
“In 2018, experts from the AAMI, ESH, and ISO agreed on a Universal Standard (ISO 81060–2: 2018) for global use [17], [18], [19], and a cuff amendment subsequently published in 2020 [20], all these three organizations encouraged the exclusive use of this protocol [21].”
O uso de metodologias ativas no ensino das etapas da medida indireta da pressão arterial
Bachur, C. A. K. (2021) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.22.2021.tde-24032021-161050 · Cited by 1
Sharman, J. E. (2023) · Journal of Human Hypertension · doi:10.1038/s41371-023-00806-0 · Cited by 1
“Efforts to redress this problem and to increase the global availability of accurate BPMDs have been initiated [4], and this special issue is part of this endeavor, which is supported by the World Hypertension League, The Lancet Commission on Hypertension Group and other organizations.”
BackgroundSelf-citationSteckelings, U. M., & Charchar, F. (2020) · Hypertension News · doi:10.30824/2006-1
Putting the pressure on nonvalidated blood pressure monitors
(2020) · Hypertension News · doi:10.30824/2006-17
Hypertension Care During Emergencies and Pandemics
Samuel, J. P., & Hyman, B. K. (2022) · Springer eBooks · doi:10.1007/978-3-319-31420-4_63-1
Ordúñez, P., Lombardi, C., Picone, D. S., Brady, T. M., Campbell, N. R. C., Moran, A. E., Padwal, R. S., Rosende, A., Whelton, P. K., & Sharman, J. E. (2022) · Revista Panamericana de Salud Pública · doi:10.26633/rpsp.2022.50
“Estos dispositivos de medición de la presión arterial no validados que se utilizan en la práctica clínica tienen más probabilidades de ser inexactos (6).”
BackgroundSelf-citationb. Asia/Australia Research Centers
(2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15512-3.00043-x
d. Latin American Research Centers
(2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15512-3.00042-8
Kékes, E., & Barna, I. (2024) · Hypertonia és Nephrologia · doi:10.33668/hn.28.014
Alotaibi, R. K., Alrashdi, B., Alhashmi, N., El-bashir, B. O., & Eledum, H. (2024) · Global Journal of Health Science · doi:10.5539/gjhs.v16n7p64
“…been influenced across the global spectrum which includes government organizations (regulatory agencies of FDA), non-government organizations (societies working on hypertension, and blood pressure), groups of health professionals, manufacturers and consumers of BP devices (Sharman et al., 2020).”
BackgroundRoyero, M. C. L., Rebolledo-Cobos, R., Leyva, A. D. J. C., & Pereira, L. A. (2025) · Movimiento Científico · doi:10.33881/2011-7191.mtc.19106
An Evidence-Based Practice Initiative to Improve Blood Pressure Control
Hines, T. D. (2025) · The Research Repository @ WVU (West Virginia University) · doi:10.33915/etd.12999
Mazzaresi, Y., Cicero, C., Ortego, J., Ortega, D. A. E., Luna, C., & Rodríguez-Fernández, R. (2025) · Revista Panamericana de Salud Pública · doi:10.26633/rpsp.2025.122
“It contributes to the evidence base of how decentralized health systems can institutionalize cardiovascular prevention through primary care reform and collaborative implementation (7, 13, 16).”
Batan, K. J. C., Posadas, K. R. R., & Urmaza-Olarte, A. (2025) · Philippine Journal of Internal Medicine · doi:10.65564/pjim.18ced5646f
Pradhan, M. R., & De, P. (2024) · Figshare · doi:10.6084/m9.figshare.25123914
Yang, Z., Li, T., Shen, J., Huang, Y., Lei, C., Yu, J., Ma, Z., Zhang, M., & Li, Y. (2026) · BMC Cancer · doi:10.1186/s12885-026-15667-2 · Cited by 1
“Liver cancer is a malignant tumor of the digestive sys-tem with a high incidence rate and mortality rate, and it is one of the most difficult cancers to treat [1].”
Zelveian, P., Hakobyan, Z., Topouchian, J. A., Avagyan, A., Gharibyan, H., & Asmar, R. G. (2026) · Vascular Health and Risk Management · doi:10.2147/vhrm.s585947
“Therefore, future studies are needed to assess the accuracy of the BPM Pro2 (WPM07) device in these special populations.”
Self-citationImpact of Blood Pressure Measurement Errors on CVD Risk Prediction in New Zealand
Chandel, T. (2025) · Tuwhera (Auckland University of Technology)
Mancusi, C., Šinigoj, P., Antza, C., Belančić, A., Motiejūnaitė, J., Tähtisalo, H. S., Ferrão, D., & Palatini, P. (2026) · Blood Pressure · doi:10.1080/08037051.2026.2646368
Self-citationShi, Y., Li, S., Hang, S., Du, C., & Dai, H. (2026) · Eurasian Journal of Medicine and Oncology · doi:10.36922/ejmo026090103
Avagyan, A., Zelveian, P., Topouchian, J. A., Hakobyan, Z., Gharibyan, H., & Asmar, R. G. (2026) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000801
Self-citationKusumayanti, I., WIJAYANTI, E., & Wahidah, N. (2026) · JURNAL PENGELOLAAN LABORATORIUM SAINS DAN TEKNOLOGI · doi:10.33369/pelastek.v6i1.49364
聴診法による血圧の変動量評価に基づく生体計測法の標準化に関する研究
Yamashita, S. (2026) · Institutional Repositories DataBase (IRDB) · doi:10.20556/0002008393
Chen, X., Huang, Y., Xu, J., Hong, K., & Su, H. (2026) · European journal of medical research · doi:10.1186/s40001-026-04788-w
“As Sharman and colleagues noted in the Lancet Commission on Hypertension position statement, a systematic measurement error of only 5 mmHg can lead to misclassification of BP status in tens of millions of people worldwide [18].”
Role of chrononutrition in modulating metabolic and cardiovascular health
Shukla, V., Hussain, S., Fatima, G., KHAN, S. K., Hadi, N. R., Fedačko, J., & Магомедова, А. У. (2026) · Scripta Medica · doi:10.5937/scriptamed57-63638
Sciepuro, R., Czarnowska, M., & Czarnowska, N. (2026) · International Journal of Innovative Technologies in Social Science · doi:10.31435/ijitss.3(51).2026.6352
Kim, H., Kim, B. S., Shin, J., & Shin, J. (2026) · Clinical Hypertension · doi:10.5646/ch.2026.32.e41
“This pattern has also been observed in oscillometric and cuffless BP validation studies that compared noninvasive measurements with intra-arterial reference standards [17,18].”
PREVALENCE OF HYPERTENSION IN THE PARAGUAY POPULATION
Gustavo, C. P., Mosquera, C. B., & Sharman, R. S. (2022) · African Journal of Emerging Issues
Davis, L. L., Yang, E., Blyler, C. A., Cluett, J., Cohen, J. B., Juraschek, S. P., Reilly, J. P., & Tobb, K. (2026) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2026.08.028 · Cited by 1
Metadata
- Authors
- Sharman, J. E., O’Brien, E., Alpert, B., Schutte, A. E., Delles, C., Hecht Olsen, M., Asmar, R., Atkins, N., Barbosa, E., Calhoun, D., Campbell, N. R. C., Chalmers, J., Benjamin, I., Jennings, G., Laurent, S., Boutouyrie, P., Lopez-Jaramillo, P., McManus, R. J., Mihailidou, A. S., Ordunez, P., Padwal, R., Palatini, P., Parati, G., Poulter, N., Rakotz, M. K., Rosendorff, C., Saladini, F., Scuteri, A., Sebba Barroso, W., Cho, M.-C., Sung, K.-C., Townsend, R. R., Wang, J.-G., Willum Hansen, T., Wozniak, G., & Stergiou, G.
- Affiliations
- University College Dublin (IE)
- University of Tennessee Health Science Center (US)
- North-West University (ZA)
- University of Glasgow (GB)
- University of Alabama at Birmingham (US)
- University of Calgary (CA)
- UNSW Sydney (AU)
- American Heart Association (US)
- The University of Sydney (AU)
- Inserm (FR)
- University of Oxford (GB)
- Royal North Shore Hospital (AU)
- University of Alberta (CA)
- University of Padua (IT)
- IRCCS Istituto Auxologico Italiano (IT)
- Imperial College London (GB)
- American Medical Association (US)
- Holbæk Sygehus (DK)
- University of Southern Denmark (DK)
- Corresponding author
- Alpert, Bruce
- ORCID
- Sharman, James E.
- O’Brien, Eoin
- Alpert, Bruce
- Schutte, Aletta E.
- Delles, Christian
- Asmar, Roland
- Atkins, Neil
- Barbosa, Eduardo
- Calhoun, David
- Campbell, Norm R.C.
- Chalmers, John
- Benjamin, Ivor
- Jennings, Garry
- Laurent, Stéphane
- Boutouyrie, Pierre
- McManus, Richard J.
- Mihailidou, Anastasia S.
- Padwal, Raj
- Palatini, Paolo
- Parati, Gianfranco
- Poulter, Neil
- Rakotz, Michael K.
- Rosendorff, Clive
- Saladini, Francesca
- Scuteri, Angelo
- Cho, Myeong-Chan
- Sung, Ki-Chul
- Townsend, Raymond R.
- Wang, Ji-Guang
- Wozniak, Gregory
- Stergiou, George
- Venue
- Journal of Hypertension
- Published
- 2020-01
- Volume
- 38
- Issue
- 1
- Pages
- 21-29
- ISSN
- 0263-6352 (ISSN-L)
- PMC
- PMC6919228
- OpenAlex
- W2973007128
- Semantic Scholar
- 2413d689ae41fec25f61910c94f550039881bba8
- Cited by
- 139
- References
- 58
- Citations by year
- 2026: 13 · 2025: 17 · 2024: 13 · 2023: 16 · 2022: 37 · 2021: 20 · 2020: 22
- FWCI
- 14.45
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Journal of Hypertension (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- UTAS Research Repository (acceptedVersion)
- UNSWorks (UNSW Sydney) (submittedVersion, cc-by-nc-nd)
- UNSWorks (University of New South Wales, Sydney, Australia) (submittedVersion, cc-by-nc-nd)
- University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion, cc-by-nc-nd)
- LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion, cc-by-nc-nd)
- Boloka Institutional Repository (North-west University) (submittedVersion)
- UNICA IRIS Institutional Research Information System (University of Cagliari) (submittedVersion, other-oa)
- UnissResearch (Università degli Studi di Sassari) (submittedVersion)
- Spiral (Imperial College London) (submittedVersion, other-oa)
- Funders
- American Heart Association
- Hjerteforeningen
- Steno Diabetes Center Copenhagen (SDCC 3.A Complications)
- National Institute for Health and Care Research (NIHR200201, NIHR-RP-02-12-015)
- National Heart Foundation of Australia
- High Blood Pressure Research Council of Australia
- Société Française d’Hypertension Artérielle
- Hypertension Canada
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Clinical practice guidelines implementation
- Keywords
- blood pressure measurement accuracy, hypertension diagnosis, device validation, medical device regulation, home blood pressure monitoring, antihypertensive therapy
- MeSH terms
- Blood Pressure Determination, Humans, Hypertension, Practice Guidelines as Topic, Sphygmomanometers
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.