The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Comparison of aortic pulse wave velocity measured by three techniques: Complior, SphygmoCor and Arteriograph
Abstract
BACKGROUND: New 2007 European Society of Hypertension guidelines recommend measuring arterial stiffness in patients with arterial hypertension, suggesting a carotid-femoral pulse wave velocity over 12 m/s as an estimate of subclinical organ damage. Considering this cutoff point, it is worth exploring whether or not there are significant differences in results obtained using various techniques for measuring aortic pulse wave velocity. The aim of the study was to compare aortic pulse wave velocity measurements using Complior, SphygmoCor, and Arteriograph devices, and to assess the effect of pulse wave transit time and traveled distance on pulse wave velocity values. METHODS: Aortic pulse wave velocity was measured on a single visit, using these devices, in randomized order, in a group of 64 patients with grade 1 or 2 arterial hypertension. RESULTS: Aortic pulse wave velocity measured using Complior (10.1 +/- 1.7 m/s) was significantly higher than that obtained using SphygmoCor (8.1 +/- 1.1 m/s) or Arteriograph (8.6 +/- 1.3 m/s). No differences were noted between pulse wave velocity measurements using SphygmoCor and Arteriograph. Between-method comparison revealed that differences in traveled distance were significant: Complior versus Arteriograph [0.09 m, Confidence interval (CI): 0.08-0.12 m, P < 0.05], Complior versus SphygmoCor (0.15 m, CI: 0.13-0.16 m, P < 0.05), Arteriograph versus SphygmoCor (0.05 m, CI: 0.03-0.07 m, P < 0.05). No between-method differences were found for transit times. CONCLUSION: Differences in pulse wave velocity obtained by compared devices resulted primarily from using various methods for measuring traveled distance. It appears reasonable to establish uniform principles for the measurement of traveled distance. Because a large number of prognosis/survival studies used direct distance between carotid and femoral sites of pulse wave recording, this distance should be mostly recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Expert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077
Mancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., Laurent, S., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281fc975a · Cited by 5,824
Laurent, S., Boutouyrie, P., Asmar, R., Gautier, I., Laloux, B., Guize, L., Ducimetiere, P., & Benetos, A. (2001) · Hypertension · doi:10.1161/01.hyp.37.5.1236 · Cited by 3,856
Impact of Aortic Stiffness on Survival in End-Stage Renal Disease
Blacher, J., Guerin, A. P., Pannier, B., Marchais, S. J., Safar, M. E., & London, G. M. (1999) · Circulation · doi:10.1161/01.cir.99.18.2434 · Cited by 2,138
Boutouyrie, P., Tropeano, A. I., Asmar, R., Gautier, I., Benetos, A., Lacolley, P., & Laurent, S. (2002) · Hypertension · doi:10.1161/hy0102.099031 · Cited by 1,745
Cruickshank, K., Riste, L., Anderson, S. G., Wright, J. S., Dunn, G., & Gosling, R. G. (2002) · Circulation · doi:10.1161/01.cir.0000033824.02722.f7 · Cited by 1,531
Willum Hansen, T., Staessen, J. A., Torp-Pedersen, C., Rasmussen, S., Thijs, L., Ibsen, H., & Jeppesen, J. (2006) · Circulation · doi:10.1161/circulationaha.105.579342 · Cited by 1,515
Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients
Blacher, J., Asmar, R., Djane, S., London, G. M., & Safar, M. E. (1999) · Hypertension · doi:10.1161/01.hyp.33.5.1111 · Cited by 1,493 · cited 1×
“Again, using the Complior to measure carotid–femoral PWV and calculate traveled distance between carotid and femoral sites directly on body surface, a relationship was found between PWV greater than 13 m/s and reduced survival in patients with arterial hypertension [ 22 ].”
MethodAsmar, R., Benetos, A., Topouchian, J., Laurent, P., Pannier, B., Brisac, A.-M., Target, R., & Levy, B. I. (1995) · Hypertension · doi:10.1161/01.hyp.26.3.485 · Cited by 1,376
Aortic Stiffness Is an Independent Predictor of Fatal Stroke in Essential Hypertension
Laurent, S., Katsahian, S., Fassot, C., Tropeano, A.-I., Gautier, I., Laloux, B., & Boutouyrie, P. (2003) · Stroke · doi:10.1161/01.str.0000065428.03209.64 · Cited by 1,057
Evaluation of Carotid-Femoral Pulse Wave Velocity: Influence of Timing Algorithm and Heart Rate
Millasseau, S. C., Stewart, A. D., Patel, S. J., Redwood, S. R., & Chowienczyk, P. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000154229.97341.d2 · Cited by 289
El Assaad, M. A., Topouchian, J. A., & Asmar, R. G. (2003) · Blood Pressure Monitoring · doi:10.1097/00126097-200306000-00006 · Cited by 224
Stewart, A. D., Millasseau, S., Kearney, M. T., Ritter, J. M., & Chowienczyk, P. (2003) · Hypertension · doi:10.1161/01.hyp.0000092882.65699.19 · Cited by 148
Diabetes mellitus and renal failure: effects on large artery stiffness
Bahous, S. A., Blacher, J., Safar, M. E., & Mourad, J. (2001) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001253 · Cited by 125
Stewart, A. D., Jiang, B., Millasseau, S., Ritter, J. M., & Chowienczyk, P. (2006) · Hypertension · doi:10.1161/01.hyp.0000237669.64066.c5 · Cited by 96
Pulse Wave Velocity Is Inversely Related to Vertebral Bone Density in Hemodialysis Patients
Raggi, P., Bellasi, A., Ferramosca, E., Block, G. A., & Muntner, P. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.086942 · Cited by 86
Reference Values for SphygmoCor Measurements in South Africans of African Ancestry
SHIBURI, C., Staessen, J. A., Maseko, M. J., Wojciechowska, W., Thijs, L., VANBORTEL, L., Woodiwiss, A. J., & Norton, G. R. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.06.018 · Cited by 85
Self-citationSchillaci, G., Mannarino, M. R., Pucci, G., Pirro, M., Helou, J., Savarese, G., Vaudo, G., & Mannarino, E. (2007) · Hypertension · doi:10.1161/01.hyp.0000255790.98391.9b · Cited by 70
Arterial Compliance by Cuff Sphygmomanometer
Brinton, T. J., Kailasam, M. T., Wu, R. A., Cervenka, J. H., Chio, S., Parmer, R. J., DeMaria, A. N., & O’Connor, D. T. (1996) · Hypertension · doi:10.1161/01.hyp.28.4.599 · Cited by 54
Kucerová, J., Filipovský, J., Staessen, J. A., Cwynar, M., Wojciechowska, W., Stolarz, K., Kuznetsova, T., Gąsowski, J., Dolejšová, M., & Grodzicki, T. K. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.09.015 · Cited by 49
Self-citationBørresen, M. L., Wang, D., & Strandgaard, S. (2007) · American Journal of Nephrology · doi:10.1159/000101369 · Cited by 48
Pulse wave velocity is increased in patients with transient myocardial ischemia
Baulmann, J., Homsi, R., Uen, S., Düsing, R., Fimmers, R., Vetter, H., & Mengden, T. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000244959.92856.7e · Cited by 19
Magometschnigg, D. (2005) · Wiener Medizinische Wochenschrift · doi:10.1007/s10354-005-0209-x · Cited by 18
Cited by
The Reference Values for Arterial Stiffness' Collaboration (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq165 · Cited by 2,087
Townsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473
Tanaka, H., Munakata, M., Kawano, Y., Ohishi, M., Shoji, T., Sugawara, J., Tomiyama, H., Yamashina, A., Yasuda, H., Sawayama, T., et al. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e32832e94e7 · Cited by 580
Horváth, I. G., Németh, Á., Lenkey, Z., Alessandri, N., Tufano, F., Kis, P., Gaszner, B., & Cziráki, A. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e32833c8a1a · Cited by 374
A Wearable and Highly Sensitive Graphene Strain Sensor for Precise Home-Based Pulse Wave Monitoring
Yang, T., Jiang, X., Zhong, Y., Zhao, X., Lin, S., Li, J., Li, X., Xu, J., Li, Z., & Zhu, H. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00230 · Cited by 321
Metadata
- Authors
- Rajzer, M. W., Wojciechowska, W., Klocek, M., Palka, I., Brzozowska-Kiszka, M., & Kawecka-Jaszcz, K.
- Venue
- Journal of Hypertension
- Published
- 2008-10
- Volume
- 26
- Issue
- 10
- Pages
- 2001-2007
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2066036954
- Cited by
- 308
- References
- 23
- FWCI
- 12.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.