Comparison of aortic pulse wave velocity measured by three techniques: Complior, SphygmoCor and Arteriograph
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
BACKGROUND: New 2007 European Society of Hypertension guidelines recommend measuring arterial stiffness in patients with arterial hypertension, suggesting a carotid-femoral pulse wave velocity over 12 m/s as an estimate of subclinical organ damage. Considering this cutoff point, it is worth exploring whether or not there are significant differences in results obtained using various techniques for measuring aortic pulse wave velocity. The aim of the study was to compare aortic pulse wave velocity measurements using Complior, SphygmoCor, and Arteriograph devices, and to assess the effect of pulse wave transit time and traveled distance on pulse wave velocity values. METHODS: Aortic pulse wave velocity was measured on a single visit, using these devices, in randomized order, in a group of 64 patients with grade 1 or 2 arterial hypertension. RESULTS: Aortic pulse wave velocity measured using Complior (10.1 +/- 1.7 m/s) was significantly higher than that obtained using SphygmoCor (8.1 +/- 1.1 m/s) or Arteriograph (8.6 +/- 1.3 m/s). No differences were noted between pulse wave velocity measurements using SphygmoCor and Arteriograph. Between-method comparison revealed that differences in traveled distance were significant: Complior versus Arteriograph [0.09 m, Confidence interval (CI): 0.08-0.12 m, P < 0.05], Complior versus SphygmoCor (0.15 m, CI: 0.13-0.16 m, P < 0.05), Arteriograph versus SphygmoCor (0.05 m, CI: 0.03-0.07 m, P < 0.05). No between-method differences were found for transit times. CONCLUSION: Differences in pulse wave velocity obtained by compared devices resulted primarily from using various methods for measuring traveled distance. It appears reasonable to establish uniform principles for the measurement of traveled distance. Because a large number of prognosis/survival studies used direct distance between carotid and femoral sites of pulse wave recording, this distance should be mostly recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Expert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077 · cited 2×
“The ‘Expert consensus document on arterial stiffness’ [ 1 ] describes three methods for measuring traveled distance: using the total distance between the carotid and femoral sites of measurement, subtracting the distance from the carotid location to the sternal notch from the total distance, or subtracting the distanc…”
BackgroundMancia, G., De Backer, G., Dominiczak, A., Cifkova, R., Fagard, R., Germano, G., Grassi, G., Heagerty, A. M., Kjeldsen, S. E., Laurent, S., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281fc975a · Cited by 5,824
Laurent, S., Boutouyrie, P., Asmar, R., Gautier, I., Laloux, B., Guize, L., Ducimetiere, P., & Benetos, A. (2001) · Hypertension · doi:10.1161/01.hyp.37.5.1236 · Cited by 3,856
Impact of Aortic Stiffness on Survival in End-Stage Renal Disease
Blacher, J., Guerin, A. P., Pannier, B., Marchais, S. J., Safar, M. E., & London, G. M. (1999) · Circulation · doi:10.1161/01.cir.99.18.2434 · Cited by 2,138 · cited 1×
“Carotid–femoral PWV greater than 12 m/s as a prognostic factor was first referred to by Blacher et al. [ 20 ] in patients with renal failure.”
BackgroundBoutouyrie, P., Tropeano, A. I., Asmar, R., Gautier, I., Benetos, A., Lacolley, P., & Laurent, S. (2002) · Hypertension · doi:10.1161/hy0102.099031 · Cited by 1,745
Cruickshank, K., Riste, L., Anderson, S. G., Wright, J. S., Dunn, G., & Gosling, R. G. (2002) · Circulation · doi:10.1161/01.cir.0000033824.02722.f7 · Cited by 1,531
Willum Hansen, T., Staessen, J. A., Torp-Pedersen, C., Rasmussen, S., Thijs, L., Ibsen, H., & Jeppesen, J. (2006) · Circulation · doi:10.1161/circulationaha.105.579342 · Cited by 1,515
Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients
Blacher, J., Asmar, R., Djane, S., London, G. M., & Safar, M. E. (1999) · Hypertension · doi:10.1161/01.hyp.33.5.1111 · Cited by 1,493 · cited 1×
“Again, using the Complior to measure carotid–femoral PWV and calculate traveled distance between carotid and femoral sites directly on body surface, a relationship was found between PWV greater than 13 m/s and reduced survival in patients with arterial hypertension [ 22 ].”
MethodAsmar, R., Benetos, A., Topouchian, J., Laurent, P., Pannier, B., Brisac, A.-M., Target, R., & Levy, B. I. (1995) · Hypertension · doi:10.1161/01.hyp.26.3.485 · Cited by 1,376
Aortic Stiffness Is an Independent Predictor of Fatal Stroke in Essential Hypertension
Laurent, S., Katsahian, S., Fassot, C., Tropeano, A.-I., Gautier, I., Laloux, B., & Boutouyrie, P. (2003) · Stroke · doi:10.1161/01.str.0000065428.03209.64 · Cited by 1,057
Cited by
The Reference Values for Arterial Stiffness' Collaboration (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq165 · Cited by 2,087
Townsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473
Tanaka, H., Munakata, M., Kawano, Y., Ohishi, M., Shoji, T., Sugawara, J., Tomiyama, H., Yamashina, A., Yasuda, H., Sawayama, T., et al. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e32832e94e7 · Cited by 580
Horváth, I. G., Németh, Á., Lenkey, Z., Alessandri, N., Tufano, F., Kis, P., Gaszner, B., & Cziráki, A. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e32833c8a1a · Cited by 374
A Wearable and Highly Sensitive Graphene Strain Sensor for Precise Home-Based Pulse Wave Monitoring
Yang, T., Jiang, X., Zhong, Y., Zhao, X., Lin, S., Li, J., Li, X., Xu, J., Li, Z., & Zhu, H. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00230 · Cited by 321
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Novel Methods for Pulse Wave Velocity Measurement
Pereira, T., Correia, C., & Cardoso, J. (2015) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-015-0086-8 · Cited by 284
Weber, T., Ammer, M., Rammer, M., Adji, A., O'Rourke, M. F., Wassertheurer, S., Rosenkranz, S., & Eber, B. (2009) · Journal of Hypertension · doi:10.1097/hjh.0b013e32832cb04e · Cited by 262
Current assessment of pulse wave velocity: comprehensive review of validation studies
Milan, A., Zocaro, G., Leone, D., Tosello, F., Buraioli, I., Schiavone, D., & Veglio, F. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002081 · Cited by 236
“Similar findings were described by other authors when comparing the Complior SP and SphygmoCor devices [26,27].”
BackgroundResultInfluentialWilkinson, I. B., McEniery, C. M., Schillaci, G., Boutouyrie, P., Segers, P., Donald, A., & Chowienczyk, P. J. (2010) · Artery Research · doi:10.1016/j.artres.2010.03.001 · Cited by 202
Validity and repeatability of the Vicorder apparatus: a comparison with the SphygmoCor device
Hickson, S. S., Butlin, M., Broad, J., Avolio, A. P., Wilkinson, I. B., & McEniery, C. M. (2009) · Hypertension Research · doi:10.1038/hr.2009.154 · Cited by 189
Review of MRI-based measurements of pulse wave velocity: a biomarker of arterial stiffness.
Wentland, A. L., Grist, T. M., & Wieben, O. E. (2014) · PubMed · doi:10.3978/j.issn.2223-3652.2014.03.04 · Cited by 166
“However, the distance measurement used in applanation tonometry and Doppler ultrasound can cause errors of up to 30% for the measurement of PWV (2,11,12).”
MethodNabeel, P. M., Karthik, S., Joseph, J., & Sivaprakasam, M. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2800539 · Cited by 72
“This method is commonly used in commercial PWV devices such as SphygmoCor [11], PulsePen [12]–[14], and Complior [11], [14].”
MethodDhaun, N., Moorhouse, R., MacIntyre, I. M., Melville, V., Oosthuyzen, W., Kimmitt, R. A., Brown, K. E., Kennedy, E. D., Goddard, J., & Webb, D. J. (2014) · Hypertension · doi:10.1161/hypertensionaha.114.03533 · Cited by 54
“The arteriograph has been validated against an invasive measure of aortic PWV(21) and 2 commonly used noninvasive measurement devices, the Complior and SphygmoCor.(22,23) Data presented are for brachial BP with day defined as 0630 to 1800 and night as 1830 to 0600.”
MethodExperimental validation of dual PPG local pulse wave velocity probe
Nabeel, P. M., Karthik, S., Joseph, J., & Sivaprakasam, M. (2017) · 2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2017.7985911 · Cited by 20
“PWV measurements in the currently available devices such as PulsePen® [2], Complior® [3], SphygmoCor® [4] are performed over large arterial segments.”
Method
Metadata
- Authors
- Rajzer, M. W., Wojciechowska, W., Klocek, M., Palka, I., Brzozowska-Kiszka, M., & Kawecka-Jaszcz, K.
- Venue
- Journal of Hypertension
- Published
- 2008-10
- Volume
- 26
- Issue
- 10
- Pages
- 2001-2007
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2066036954
- Cited by
- 308
- References
- 23
- FWCI
- 12.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.