CoChat

Blood pressure measurement in very obese patients: a challenging problem

Palatini, Paolo, Parati, Gianfranco · 2011 · Journal of Hypertension
Cited by 72

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

To obtain a reliable blood pressure (BP) measurement, several methodological requirements have to be satisfied. Conditions for optimal BP measurement include [1]:(1) Full explanation of the procedure and proper patient’s education. (2) Correct attitude of patient and observer. (3) Correct posture of the patient. (4) Arm support. (5) Arm position at heart level. (6) Proper arm selection. (7) Selection of cuff and bladder of adequate size. Among these requirements, choice of an appropriate cuff and bladder size is an essential prerequisite for accurate BP assessment. In fact, use of cuffs containing bladders of inappropriate dimension is the source of substantial measurement errors, which may lead to misclassification of patients’ BP levels in clinical practice (Table 1) [2]. Undercuffing is responsible for a spurious overestimation of BP in patients with large arms leading to overdiagnosis of hypertension, whereas overcuffing (that is, use of relatively large cuffs with small arms), may be responsible for an opposite problem, leading to erroneous underestimation of BP levels. Thus, the inflatable rubber bladder should be long enough to match the arm circumference and should be contained within an inelastic cloth, the full length of which should extend beyond the end of the inflatable bladder [1,2]. Most guidelines recommend a bladder width and length of 40 and 80% of arm circumference, respectively [3–5]. These recommendations are often neglected by healthcare professionals because they imply availability of cuffs of different size and require measurement of arm circumference to be routinely implemented in clinical practice [1,5]. To overcome these problems, several procedures and a few technical solutions have been proposed [1,5], but for reasons of cost and practicality none have become popular.Among them, correction formulae have been suggested to adjust for measurement errors, a procedure which has the disadvantage of further complicating the measurement of BP in a clinical setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0b013e3283435b65

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 72

Metadata

Authors
Palatini, P., & Parati, G.
Venue
Journal of Hypertension
Published
2011-03
Volume
29
Issue
3
Pages
425-429
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2080432183
Cited by
72
References
5
FWCI
1.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Blood pressure measurement in very obese patients: a challenging problem. https://app.cochat.ai/papers/10.1097/hjh.0b013e3283435b65
The paper
Palatini, P., & Parati, G. (2011). Blood pressure measurement in very obese patients: a challenging problem. Journal of Hypertension. https://doi.org/10.1097/hjh.0b013e3283435b65

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.