Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
HYPOTHESIS: Suboptimal cochlear implant (CI) electrode array placement may reduce presentation of coded information to the central nervous system and, consequently, limit speech recognition. BACKGROUND: Generally, mean speech reception scores for CI recipients are similar across different CI systems, yet large outcome variation is observed among recipients implanted with the same device. These observations suggest significant recipient-dependent factors influence speech reception performance. This study examines electrode array insertion depth and scalar placement as recipient-dependent factors affecting outcome. METHODS: Scalar location and depth of insertion of intracochlear electrodes were measured in 14 patients implanted with Advanced Bionics electrode arrays and whose word recognition scores varied broadly. Electrode position was measured using computed tomographic images of the cochlea and correlated with stable monosyllabic word recognition scores. RESULTS: Electrode placement, primarily in terms of depth of insertion and scala tympani versus scala vestibuli location, varies widely across subjects. Lower outcome scores are associated with greater insertion depth and greater number of contacts being located in scala vestibuli. Three patterns of scalar placement are observed suggesting variability in insertion dynamics arising from surgical technique. CONCLUSION: A significant portion of variability in word recognition scores across a broad range of performance levels of CI subjects is explained by variability in scalar location and insertion depth of the electrode array. We suggest that this variability in electrode placement can be reduced and average speech reception improved by better selection of cochleostomy sites, revised insertion approaches, and control of insertion depth during surgical placement of the array.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nadol, J. B., Young, Y.-S., & Glynn, R. J. (1989) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348948909800602 · Cited by 392
The Size of the Cochlea and Predictions of Insertion Depth Angles for Cochlear Implant Electrodes
Escudé, B., James, C., Deguine, O., Cochard, N., Eter, E., & Fraysse, B. (2006) · Audiology and Neurotology · doi:10.1159/000095611 · Cited by 376
Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
Shepherd, R. K., Hatsushika, S., & Clark, G. M. (1993) · Hearing Research · doi:10.1016/0378-5955(93)90265-3 · Cited by 360
Quality Control After Insertion of the Nucleus Contour and Contour Advance Electrode in Adults
Aschendorff, A., Kromeier, J., Klenzner, T., & Laszig, R. (2007) · Ear & Hearing · doi:10.1097/aud.0b013e318031542e · Cited by 310
Histopathology of Cochlear Implants in Humans
Nadol, J. B., Burgess, B. J., Gantz, B. J., Coker, N. J., Ketten, D. R., Kos, I., Roland, J. T., Shiao, J. Y., Eddington, D. K., Montandon, P., et al. (2001) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348940111000914 · Cited by 292
Leake, P. A., Hradek, G. T., & Snyder, R. L. (1999) · The Journal of Comparative Neurology · doi:10.1002/(sici)1096-9861(19991004)412:4<543::aid-cne1>3.0.co;2-3 · Cited by 276
In Vivo Estimates of the Position of Advanced Bionics Electrode Arrays in the Human Cochlea
Skinner, M. W., Holden, T. A., Whiting, B. R., Voie, A. H., Brunsden, B., Neely, J. G., Saxon, E. A., Hullar, T. E., & Finley, C. C. (2007) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348940711600401 · Cited by 243
Self-citationSkinner, M. W., Ketten, D. R., Holden, L. K., Harding, G. W., Smith, P. G., Gates, G. A., Neely, J. G., Kletzker, G. R., Brunsden, B., & Blocker, B. (2002) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s101620020013 · Cited by 223
Self-citationKetten, D. R., Skinner, M. W., Wang, G., Vannier, M. W., Gates, G. A., & Neely, J. G. (1998) · PubMed · Cited by 222
Self-citationRoland, J. T. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000167993.05007.35 · Cited by 192
Deafness-Induced Changes in the Auditory Pathway: Implications for Cochlear Implants
Shepherd, R. K., & Hardie, N. A. (2001) · Audiology and Neurotology · doi:10.1159/000046843 · Cited by 189
Skinner, M. W., Holden, L. K., Whitford, L. A., Plant, K. L., Psarros, C., & Holden, T. A. (2002) · Ear and Hearing · doi:10.1097/00003446-200206000-00005 · Cited by 164
Self-citationQuality Control after Cochlear Implant Surgery by Means of Rotational Tomography
Aschendorff, A., Kubalek, R., Turowski, B., Zanella, F. E., Hochmuth, A., Schumacher, M. C., Klenzner, T., & Laszig, R. (2005) · Otology & Neurotology · doi:10.1097/00129492-200501000-00007 · Cited by 155
Briggs, R., Tykocinski, M., Xu, J. Y., Risi, F., Svehla, M., Cowan, R., Stöver, T., Erfurt, P., & Lenarz, T. (2006) · Audiology and Neurotology · doi:10.1159/000095613 · Cited by 149
Fu, Q., Shannon, R. V., & Galvin, J. J. (2002) · The Journal of the Acoustical Society of America · doi:10.1121/1.1502901 · Cited by 149
Cochlear implant histopathology.
Linthicum, F. H., Fayad, J. N., Otto, S. R., Galey, F. R., & House, W. F. (1991) · PubMed · Cited by 143
Wardrop, P. J. C., Whinney, D., Rebscher, S. J., Roland, J. T., Luxford, W. M., & Leake, P. A. (2004) · Hearing Research · doi:10.1016/j.heares.2004.11.006 · Cited by 135
Banded Intracochlear Electrode Array: Evaluation of Insertion Trauma in Human Temporal Bones
Shepherd, R. K., Pyman, B. C., Clark, G. M., & Webb, R. L. (1985) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348948509400112 · Cited by 128
Cochlear Implant Deep Electrode Insertion: Extent of Insertional Trauma
Gstoettner, W. K., Plenk, H., Jr., Franz, P., Hamzavi, J. S., Baumgartner, W., Czerny, C., & Ehrenberger, K. (1997) · Acta Oto-Laryngologica · doi:10.3109/00016489709117786 · Cited by 105
Wardrop, P. J. C., Whinney, D., Rebscher, S. J., Luxford, W. M., & Leake, P. A. (2004) · Hearing Research · doi:10.1016/j.heares.2004.11.007 · Cited by 99
Electrode Insertion Trauma in Cochlear Implantation
O'Leary, M. J., House, W. F., Fayad, J. N., & Linthicum, F. H. (1991) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348949110000901 · Cited by 97
Speech Perception with Mono- and Quadrupolar Electrode Configurations: A Crossover Study
Mens, L. H. M., & Berenstein, C. K. (2005) · Otology & Neurotology · doi:10.1097/01.mao.0000185060.74339.9d · Cited by 95
Insertional trauma of multichannel cochlear implants
Welling, D. B., Hinojosa, R., Gantz, B. J., & Lee, J. (1993) · The Laryngoscope · doi:10.1288/00005537-199309000-00010 · Cited by 75
Comparative studies of speech processing strategies for cochlear implants
Wilson, B. S., Finley, C. C., Weber, B. A., White, M. W., Farmer, J. C., Wolford, R. D., Merzenich, M. M., Lawson, D. T., Kenan, P. D., & Schindler, R. A. (1988) · The Laryngoscope · doi:10.1288/00005537-198810000-00009 · Cited by 74
Self-citationPfingst, B. E., Franck, K. H., Xu, L., Bauer, E., & Zwolan, T. A. (2001) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s101620010065 · Cited by 72
Strategies to improve electrode positioning and safety in cochlear implants
Rebscher, S. J., Heilmann, M. R., Bruszewski, W., Talbot, N. H., Snyder, R. L., & Merzenich, M. M. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.748987 · Cited by 62
Histopathology of human cochlear implants: Correlation of psychophysical and anatomical measures
Khan, A. M., Whiten, D. M., Nadol, J. B., & Eddington, D. K. (2005) · Hearing Research · doi:10.1016/j.heares.2005.03.003 · Cited by 59
Evaluating cochlear implant trauma to the scala vestibuli
Adunka, O. F., Kiefer, J., Unkelbach, M. H., Radeloff, A., & Gstoettner, W. (2005) · Clinical Otolaryngology · doi:10.1111/j.1365-2273.2004.00935.x · Cited by 53
Shepherd, R. K., Hartmann, R., Heid, S., Hardie, N. A., & Klinke, R. (1997) · Acta Oto-Laryngologica · doi:10.3109/00016489709126141 · Cited by 50
Khan, A. M., Handzel, O., Eddington, D. K., et al. (2005) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348940511400508 · Cited by 49
Optimizing Cochlear Implant Speech Performance
Skinner, M. W. (2003) · Annals of Otology Rhinology & Laryngology · doi:10.1177/00034894031120s903 · Cited by 47
Self-citationClinical Evaluation of the Clarion CII HiFocus 1 with and Without Positioner
van der Beek, F. B., Boermans, P. P. B. M., Verbist, B. M., Briaire, J. J., & Frijns, J. H. M. (2005) · Ear and Hearing · doi:10.1097/01.aud.0000188116.30954.21 · Cited by 43
Bacciu, S., Bacciu, A., Pasanisi, E., Vincenti, V., Guida, M., Barbot, A., & Berghenti, M. T. (2002) · Otology & Neurotology · doi:10.1097/00129492-200205000-00019 · Cited by 31
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Blamey, P., Artieres, F., Başkent, D., Bergeron, F., Beynon, A., Burke, E., Dillier, N., Dowell, R., Fraysse, B., Gallégo, S., et al. (2013) · Audiology and Neurotology · doi:10.1159/000343189 · Cited by 676
Impact of electrode design and surgical approach on scalar location and cochlear implant outcomes
Wanna, G. B., Noble, J. H., Carlson, M. L., Gifford, R. H., Dietrich, M. S., Haynes, D. S., Dawant, B. M., & Labadie, R. F. (2014) · The Laryngoscope · doi:10.1002/lary.24728 · Cited by 321
Automatic Segmentation of Intracochlear Anatomy in Conventional CT
Noble, J. H., Labadie, R. F., Majdani, O., & Dawant, B. M. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2160262 · Cited by 168
“manually aligned with the image to identify electrode position [1], [23].”
MethodClinical Evaluation of an Image-Guided Cochlear Implant Programming Strategy
Noble, J. H., Gifford, R. H., Hedley-Williams, A. J., Dawant, B. M., & Labadie, R. F. (2014) · Audiology and Neurotology · doi:10.1159/000365273 · Cited by 162
“Research has demonstrated, however, that many implanted arrays are not in the correct scala throughout the entire insertion depth [Finley et al., 2007; Holden et al., 2013; Skinner et al., 2007; Wanna et al., 2011], thus challenging the assumptions underlying a one-size-fits-all strategy.”
Background
Metadata
- Authors
- Finley, C. C., Holden, T. A., Holden, L. K., Whiting, B. R., Chole, R. A., Neely, G. J., Hullar, T. E., & Skinner, M. W.
- Venue
- Otology & Neurotology
- Published
- 2008-10
- Volume
- 29
- Issue
- 7
- Pages
- 920-928
- ISSN
- 1531-7129 (ISSN-L)
- OpenAlex
- W1973593620
- Cited by
- 549
- References
- 33
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.