Artificial Intelligence Algorithm for Screening Heart Failure with Reduced Ejection Fraction Using Electrocardiography
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Although heart failure with reduced ejection fraction (HFrEF) is a common clinical syndrome and can be modified by the administration of appropriate medical therapy, there is no adequate tool available to perform reliable, economical, early-stage screening. To meet this need, we developed an interpretable artificial intelligence (AI) algorithm for HFrEF screening using electrocardiography (ECG) and validated its performance. This retrospective cohort study included two hospitals. An AI algorithm based on a convolutional neural network was developed using 39,371 ECG results from 17,127 patients. The internal validation included 3,470 ECGs from 2,908 patients. Furthermore, we conducted external validation using 4,362 ECGs from 4,176 patients from another hospital to verify the applicability of the algorithm across different centers. The end-point was to detect HFrEF, defined as an ejection fraction <40%. We also visualized the regions in 12 lead ECG that affected HFrEF detection in the AI algorithm and compared this to the previously documented literature. During the internal and external validation, the areas under the curves of the AI algorithm using a 12 lead ECG for detecting HFrEF were 0.913 (95% confidence interval, 0.902–0.925) and 0.961 (0.951–0.971), respectively, and the areas under the curves of the AI algorithm using a single-lead ECG were 0.874 (0.859–0.890) and 0.929 (0.911–0.946), respectively. The deep learning-based AI algorithm performed HFrEF detection well using not only a 12 lead but also a single-lead ECG. These results suggest that HFrEF can be screened not only using a 12 lead ECG, as is typical of a conventional ECG machine, but also with a single-lead ECG performed by a wearable device employing the AI algorithm, thereby preventing irreversible disease progression and mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Colvin, M. M., Drazner, M. H., Filippatos, G. S., Fonarow, G. C., Givertz, M. M., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000509 · Cited by 3,109
Epidemiology and risk profile of heart failure
Bui, A. L., Horwich, T. B., & Fonarow, G. C. (2011) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2010.165 · Cited by 2,077 · cited 1×
“1,2 The survival rate for HF with reduced ejection fraction (HFrEF) at 3 years from the time of diagnosis is only 24%; as such, this condition often has a worse prognosis than several common cancers.”
BackgroundAttia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389 · cited 1×
“12,13 In a previous study, we developed an AI algorithm for screening HFrEF using features of ECG. 14 However, due to the information loss caused by the use of the features rather than raw data, the performance of the developed algorithm was limited.”
MethodKim, B., Wattenberg, M., Gilmer, J., Cai, C., Wexler, J., Viegas, F., & Sayres, R. (2017) · arXiv · doi:10.48550/arxiv.1711.11279 · Cited by 1,240
Prevalence of Diabetic Retinopathy in the United States, 2005-2008
Zhang, X., Saaddine, J. B., Chou, C.-F., Cotch, M. F., Cheng, Y. J., Geiss, L. S., Gregg, E. W., Albright, A. L., Klein, B. E. K., & Klein, R. (2010) · JAMA · doi:10.1001/jama.2010.1111 · Cited by 1,196
Galasko, G. I. W., Barnes, S. C., Collinson, P., Lahiri, A., & Senior, R. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi559 · Cited by 94 · cited 2×
“9,10 Recently, deep learning-based artificial intelligence (AI) algorithms have proven a particularly effective state-of-the-art technique for solving challenging problems in the fields of computer vision, speech recognition, natural language processing, and signal processing.”
Background
Cited by
Application of artificial intelligence to the electrocardiogram
Attia, Z. I., Harmon, D. M., Behr, E. R., & Friedman, P. A. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab649 · Cited by 312
Leclercq, C., Witt, H., Hindricks, G., Katra, R. P., Albert, D., Belliger, A., Cowie, M. R., Deneke, T., Friedman, P., Haschemi, M., et al. (2022) · EP Europace · doi:10.1093/europace/euac052 · Cited by 109
Lee, S., Chu, Y., Ryu, J., Park, Y. J., Yang, S., & Koh, S. B. (2022) · Yonsei Medical Journal · doi:10.3349/ymj.2022.63.s93 · Cited by 88
Bjerkén, L. V., Rønborg, S. N., Jensen, M. T., Ørting, S. N., & Nielsen, O. W. (2022) · Heart Failure Reviews · doi:10.1007/s10741-022-10283-1 · Cited by 50
“With the emerging AIeECG technology, the idea of screening for LVSD is worth revisiting, especially in combination with BNP/NTproBNP and basic clinical information.”
BackgroundMethodResultInfluentialDeep learning to detect left ventricular structural abnormalities in chest X-rays
Bhave, S., Rodriguez, V., Poterucha, T., Mutasa, S., Aberle, D., Capaccione, K. M., Chen, Y., Dsouza, B., Dumeer, S., Goldstein, J., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehad782 · Cited by 38
Metadata
- Authors
- Cho, J., Lee, B., Kwon, J.-M., Lee, Y., Park, H., Oh, B.-H., Jeon, K.-H., Park, J., & Kim, K.-H.
- Venue
- ASAIO Journal
- Published
- 2020-07-16
- Volume
- 67
- Issue
- 3
- Pages
- 314-321
- ISSN
- 1058-2916 (ISSN-L)
- OpenAlex
- W3045055338
- Cited by
- 91
- References
- 11
- FWCI
- 4.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artificial Intelligence Algorithm for Screening Heart Failure with Reduced Ejection Fraction Using Electrocardiography. https://app.cochat.ai/papers/10.1097/mat.0000000000001218
- The paper
- Cho, J., Lee, B., Kwon, J.-M., Lee, Y., Park, H., Oh, B.-H., Jeon, K.-H., Park, J., & Kim, K.-H. (2021). Artificial Intelligence Algorithm for Screening Heart Failure with Reduced Ejection Fraction Using Electrocardiography. ASAIO Journal. https://doi.org/10.1097/mat.0000000000001218
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.