CoChat

Temporal Artery Thermometry in Children Younger Than 5 Years: A Comparison With Rectal Thermometry

Odinaka, Kelechi K., Edelu, Benedict O., Nwolisa, Charles E., Amamilo, Ifeyinwa B., Okolo, Seline N. · 2014 · Pediatric Emergency Care
Cited by 16

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Temporal artery (TA) thermometry has come as one of the new methods for temperature measurement, especially in children in whom accurate temperature monitoring can save lives. The device which is convenient and simple to use is yet to gain popularity in several parts of the world, as there are conflicting reports of its accuracy. This study compares the accuracy of the TA thermometry in children younger than 5 years using the rectal thermometry as the gold standard. METHODS: Temperature was measured simultaneously in eligible children younger than 5 years from the forehead and rectum using the TA thermometer (TAT-2000C Exergen, USA) and standard mercury in glass rectal thermometer, respectively. The difference between the mean temperatures obtained by the 2 thermometry methods was tested using the paired t test. Pearson correlation coefficient, linear regression, and Bland-Altman plot were also used to test the relationship and agreement between the 2 instruments. The sensitivity, specificity, and positive and negative predictive values were also calculated. RESULTS: Overall, the mean TA temperature (37.80°C ± 1.07°C) was significantly lower than the mean rectal temperature (38.07°C ± 0.95°C), P < 0.001. In neonates, however, the mean difference was not significant, 0.02 ± 0.59 (P = 0.810). There was a significant positive correlation between the rectal and the temporal temperatures (r = 0.80, P < 0.01). The Bland-Altman plot showed wide variation in the limit of agreement between the rectal and the TA temperatures which ranged from -1.02°C to +1.56°C. The sensitivity of the TA thermometer was 64.6% and 83.5%, respectively, at a TA fever cutoff of 38.0°C and 37.7°C. CONCLUSIONS: Temporal artery thermometer is not accurate enough for the measurement of core body temperature in children younger than 5 years. However, it may be used as a tool for screening for fever in very busy clinics and emergency room at a fever cutoff of 37.7°C.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/pec.0000000000000289

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 17

  1. Titus, 2009, Clin Pediatr (Phila), 48, 190, 10.1177/0009922808327056 · doi:10.1177/0009922808327056
  2. Ng, 2002, Hong Kong Med J, 8, 39
  3. 2001, Pediatrics, 108, 197, 10.1542/peds.108.1.197 · DOI · Paper page
  4. Young, 1979, Arch Dis Child, 93, 255
  5. Lanham, 1999, Pediatr Nurs, 25, 39
  6. Edelu, 2011, Ital J Pediatr, 37, 8, 10.1186/1824-7288-37-8 · DOI
  7. Craig, 2000, BMJ, 320, 1174, 10.1136/bmj.320.7243.1174 · DOI · Paper page
  8. Schmitz, 1995, Am J Crit Care, 4, 286, 10.4037/ajcc1995.4.4.286 · DOI · Paper page
  9. Kai, 1993, BMJ, 307, 660, 10.1136/bmj.307.6905.660 · DOI
  10. Greenes, 2001, Arch Pediatr Adolesc Med, 155, 376, 10.1001/archpedi.155.3.376 · DOI · Paper page
  11. Holzhauer, 2009, J Spec Pediatr Nurs, 14, 239, 10.1111/j.1744-6155.2009.00204.x · DOI
  12. Al-Mukhaizeem, 2004, Paediatr Child Health, 9, 461, 10.1093/pch/9.7.461 · DOI
  13. Schuh, 2004, Pediatr Emerg Care, 20, 736, 10.1097/01.pec.0000144915.78124.26 · DOI · Paper page
  14. Hebbar, 2005, Pediatr Crit Care Med, 6, 557, 10.1097/01.PCC.0000163671.69197.16 · DOI · Paper page
  15. Roy, 2003, Clin Pediatr (Phila), 42, 433, 10.1177/000992280304200508 · doi:10.1177/000992280304200508
  16. Batra, 2013, Pediatr Emerg Care, 29, 63, 10.1097/PEC.0b013e31827b5427 · DOI · Paper page
  17. Lee, 2011, Adv Neonatal Care, 11, 62, 10.1097/ANC.0b013e3182087d2b · DOI

Cited by

See all 16

Metadata

Authors
Odinaka, K. K., Edelu, B. O., Nwolisa, C. E., Amamilo, I. B., & Okolo, S. N.
Venue
Pediatric Emergency Care
Published
2014-12
Volume
30
Issue
12
Pages
867-870
ISSN
0749-5161 (ISSN-L)
OpenAlex
W2317722228
Cited by
16
References
1
FWCI
1.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Temporal Artery Thermometry in Children Younger Than 5 Years: A Comparison With Rectal Thermometry. https://app.cochat.ai/papers/10.1097/pec.0000000000000289
The paper
Odinaka, K. K., Edelu, B. O., Nwolisa, C. E., Amamilo, I. B., & Okolo, S. N. (2014). Temporal Artery Thermometry in Children Younger Than 5 Years: A Comparison With Rectal Thermometry. Pediatric Emergency Care. https://doi.org/10.1097/pec.0000000000000289

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.