The DOI matches its Crossref record; 73 of the 74 references it cites were found in a registry or an index.
Innovations in Prosthetic Interfaces for the Upper Extremity
Abstract
Advancements in modern robotic technology have led to the development of highly sophisticated upper extremity prosthetic limbs. High-fidelity volitional control of these devices is dependent on the critical interface between the patient and the mechanical prosthesis. Recent innovations in prosthetic interfaces have focused on several control strategies. Targeted muscle reinnervation is currently the most immediately applicable prosthetic control strategy and is particularly indicated in proximal upper extremity amputations. Investigation into various brain interfaces has allowed acquisition of neuroelectric signals directly or indirectly from the central nervous system for prosthetic control. Peripheral nerve interfaces permit signal transduction from both motor and sensory nerves with a higher degree of selectivity. This article reviews the current developments in each of these interface systems and discusses the potential of these approaches to facilitate motor control and sensory feedback in upper extremity neuroprosthetic devices.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, current peripheral nerve interfaces have limitations, which minimize their clinical utility (1, 2).”
From A regenerative peripheral nerve interface allows real-time control of an artificial hand in upper limb amputees (2020) · cites this paper as [1]
In the citing paper
“With this technique, the prosthetic control is more natural compared to conventional myoelectric methods, and the patients are more efficient in performing tasks [39].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [39]
In the citing paper
“This can help the transmission of sensory feedback and the attainment of electromyographic (EMG) signals by surface electrodes from the reinnervated site to control the prosthetic limb (Kung et al., 2013; Cheesborough et al., 2015).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Kung et al., 2013
Citations
Cites
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
A robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Direct Cortical Control of 3D Neuroprosthetic Devices
Taylor, D. M., Tillery, S. I. H., & Schwartz, A. B. (2002) · Science · doi:10.1126/science.1070291 · Cited by 1,540
Instant neural control of a movement signal
Serruya, M. D., Hatsopoulos, N. G., Paninski, L., Fellows, M. R., & Donoghue, J. P. (2002) · Nature · doi:10.1038/416141a · Cited by 1,409
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Research works printed but not linked: 5
- Freeland, 2007, Orthopedics, 30, 120, 10.3928/01477447-20070201-16 · doi:10.3928/01477447-20070201-16
- Tenore, 2011, Johns Hopkins APL Tech Dig, 30, 230
- Kipke, 2004, Conf Proc IEEE Eng Med Biol Soc, 7, 5344
- Slot, 1997, Artif Organs, 21, 207
- Park, 2009, Conf Proc IEEE Eng Med Biol Soc, 2009, 6789
Cited by
George, J. A., Kluger, D. T., Davis, T. S., Wendelken, S. M., Okorokova, E. V., He, Q., Duncan, C. C., Hutchinson, D. T., Thumser, Z. C., Beckler, D. T., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aax2352 · Cited by 388
Vu, P. P., Vaskov, A. K., Irwin, Z. T., Henning, P. T., Lueders, D. R., Laidlaw, A. T., Davis, A. J., Nu, C. S., Gates, D. H., Gillespie, R. B., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay2857 · Cited by 291
Self-citationWoo, S. L., Kung, T. A., Brown, D. L., Leonard, J. A., Kelly, B. M., & Cederna, P. S. (2016) · Plastic and Reconstructive Surgery - Global Open · doi:10.1097/gox.0000000000001038 · Cited by 230
Self-citationThe Billion Cell Construct: Will Three-Dimensional Printing Get Us There?
Miller, J. S. (2014) · PLoS Biology · doi:10.1371/journal.pbio.1001882 · Cited by 199
“This conceptual framework has proven useful in practice, with contemporary work applied to human patients through surgical implants such as knee, hip, and limb prostheses [2]; pacemakers; and cochlear and retinal devices [3].”
MethodKung, T. A., Langhals, N. B., Martin, D. C., Johnson, P. J., Cederna, P. S., & Urbanchek, M. G. (2014) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000000168 · Cited by 181
Self-citationApplications of sensory feedback in motorized upper extremity prosthesis: a review
Schofield, J. S., Evans, K. R., Carey, J. P., & Hebert, J. S. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.929496 · Cited by 178
“There are a limited number of institutions performing TR surgeries and as of 2013, just over 40 patients have received TR surgery [72].”
BackgroundInterfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
Mastinu, E., Doguet, P., Botquin, Y., Håkansson, B. E. V., & Ortiz-Catalan, M. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2694710 · Cited by 106
“The latter has pushed research towards the challenge of using information from the neuromuscular system in more surgically and technologically sophisticated manners [7]–[9].”
BackgroundRegenerative Peripheral Nerve Interfaces for Prevention and Management of Neuromas
Santosa, K. B., Oliver, J. D., Cederna, P. S., & Kung, T. A. (2020) · Clinics in Plastic Surgery · doi:10.1016/j.cps.2020.01.004 · Cited by 95
Self-citationThe NIH 3D Print Exchange: A Public Resource for Bioscientific and Biomedical 3D Prints
Coakley, M. F., Hurt, D. E., Weber, N. D., Mtingwa, M., Fincher, E. C., Alekseyev, V., Chen, D. T., Yun, A., Gizaw, M., Swan, J., et al. (2014) · 3D Printing and Additive Manufacturing · doi:10.1089/3dp.2014.1503 · Cited by 90
Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88
“This can help the transmission of sensory feedback and the attainment of electromyographic (EMG) signals by surface electrodes from the reinnervated site to control the prosthetic limb (Kung et al., 2013; Cheesborough et al., 2015).”
Mauch, J. T., Kao, D. S., Friedly, J. L., & Liu, Y. K. (2023) · PM&R · doi:10.1002/pmrj.12972 · Cited by 101
“7,10 Although considerable efforts have been directed toward harnessing the potential of these techniques to provide intuitive prosthetic control after amputation, their role in pain relief has attracted significant interest only in the past few years.”
BackgroundThe Evolution of Neuroprosthetic Interfaces
Adewole, D. O., Serruya, M. D., Harris, J. P., Burrell, J. C., Petrov, D., Chen, H.-C. I., Wolf, J. A., & Cullen, D. K. (2016) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2016017198 · Cited by 90
Valerio, I. L., Schulz, S. A., West, J. M., Westenberg, R. F., & Eberlin, K. R. (2020) · Plastic & Reconstructive Surgery Global Open · doi:10.1097/gox.0000000000002689 · Cited by 80
Targeted Muscle Reinnervation for Transradial Amputation: Description of Operative Technique
Morgan, E. N., Potter, B. K., Souza, J. M., Tintle, S. M., & Nanos, G. P. (2016) · Techniques in Hand and Upper Extremity Surgery · doi:10.1097/bth.0000000000000141 · Cited by 81
“In transradial amputations, this can translate into hand grasp patterns which can more closely replicate the complex motions important for prehension than what is currently possible with conventional myoelectric prostheses.(20) TMR may also provide neuroma-related pain relief benefits.”
BackgroundPet, M. A., Morrison, S. D., Mack, J. S., Sears, E. D., Wright, T. W., Lussiez, A. D., Means, K. R., Higgins, J. P., Ko, J. H., Cederna, P. S., et al. (2016) · Injury · doi:10.1016/j.injury.2016.10.004 · Cited by 78
Self-citationTaylor, C. R., Srinivasan, S. S., Yeon, S. H., O’Donnell, M. K., Roberts, T. J., & Herr, H. (2021) · Science Robotics · doi:10.1126/scirobotics.abg0656 · Cited by 69
Bergmeister, K. D., Vujaklija, I., Muceli, S., Sturma, A., Hruby, L. A., Prahm, C., Riedl, O., Salminger, S., Manzano-Szalai, K., Aman, M., et al. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00421 · Cited by 53
“Considering their complexity, it is apparent that the modern prostheses cannot be controlled intuitively with this traditional interface (Ortiz-Catalan et al., 2012; Kung et al., 2013).”
BackgroundInfluentialThe Use of 3D Printing in the Fabrication of Nasal Stents
Mills, D. K., Tappa, K. K., Jammalamadaka, U. M., Weisman, J. A., & Woerner, J. E. (2017) · Inventions · doi:10.3390/inventions3010001 · Cited by 50
“Advances in 3D printing are enabling on-demand, integrated 3D planning, and printing for personalized surgery and patient specific medical and dental devices [14,30,34].”
BackgroundUpdate in facial nerve paralysis: tissue engineering and new technologies
Langhals, N. B., Urbanchek, M. G., Ray, A., & Brenner, M. J. (2014) · Current Opinion in Otolaryngology & Head and Neck Surgery · doi:10.1097/moo.0000000000000062 · Cited by 41
Self-citationRegenerative Peripheral Nerve Interface Surgery: Anatomic and Technical Guide
Leach, G. A., Dean, R. A., Kumar, N. G., Tsai, C., Chiarappa, F. E., Cederna, P. S., Kung, T. A., & Reid, C. M. (2023) · Plastic & Reconstructive Surgery Global Open · doi:10.1097/gox.0000000000005127 · Cited by 49
Self-citationPhantom limb pain: peripheral neuromodulatory and neuroprosthetic approaches to treatment
Petersen, B. A., Nanivadekar, A. C., Chandrasekaran, S., & Fisher, L. E. (2019) · Muscle & Nerve · doi:10.1002/mus.26294 · Cited by 39
“Long-term survival of these muscle grafts, up to 20 months postimplant, has also been demonstrated in several animal experiments using RPNIs for prosthetic control.(138,139) RPNIs also prevent neuroma formation because muscle grafts act as targets for peripheral nerve ingrowth.”
BackgroundElectrically stimulated signals from a long-term Regenerative Peripheral Nerve Interface
Langhals, N. B., Woo, S. L., Moon, J. D., Larson, J. V., Leach, M. K., Cederna, P. S., & Urbanchek, M. G. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944004 · Cited by 30
“The current state of the art human interface for prosthetic control is targeted muscle reinnervation (TMR), which relies on skin-surface electromyography (EMG) for signal acquisition [1].”
BackgroundSelf-citationThe Role of Muscle Stem Cells in Regeneration and Recovery after Denervation: A Review
Wong, A., & Pomerantz, J. H. (2019) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000005370 · Cited by 30
Targeted Muscle Reinnervation for Prosthetic Control
Bergmeister, K. D., Salminger, S., & Aszmann, O. C. (2021) · Hand Clinics · doi:10.1016/j.hcl.2021.05.006 · Cited by 27
Kumar, N. G., & Kung, T. A. (2021) · Hand Clinics · doi:10.1016/j.hcl.2021.05.003 · Cited by 28
Self-citationRegenerative Peripheral Nerve Interfaces for Advanced Control of Upper Extremity Prosthetic Devices
Kumar, N. G., Kung, T. A., & Cederna, P. S. (2021) · Hand Clinics · doi:10.1016/j.hcl.2021.04.005 · Cited by 26
Self-citationFactors associated with interest in novel interfaces for upper limb prosthesis control
Engdahl, S. M., Chestek, C. A., Kelly, B. M., Davis, A. J., & Gates, D. H. (2017) · PLoS ONE · doi:10.1371/journal.pone.0182482 · Cited by 27
Future Medicine: The Impact of 3D Printing
Mills, D. K. (2015) · Journal of Nanomaterials & Molecular Nanotechnology · doi:10.4172/2324-8777.1000163 · Cited by 25
“Prosthetics Commercially available dental and orthopedic prosthetic devices are typically expensive, lack the requisite anatomical capabilities and features lack sophistication and are not customizable [15].”
BackgroundBergmeister, K. D., Hader, M., Lewis, S., Russold, M.-F., Schiestl, M., Manzano-Szalai, K., Roche, A. D., Salminger, S., Dietl, H., & Aszmann, O. C. (2015) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000001926 · Cited by 23
Peripheral Nerve Management in Extremity Amputations
Richards, J. T., Baird, M. D., Tintle, S. M., Souza, J. M., Renninger, C. H., & Potter, B. K. (2022) · Orthopedic Clinics of North America · doi:10.1016/j.ocl.2022.01.002 · Cited by 25
Zuo, K. J., Willand, M. P., Ho, E. S., Ramdial, S., & Borschel, G. H. (2018) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000004370 · Cited by 20
Chronic sensory-motor activity in behaving animals using regenerative multi-electrode interfaces,
Desai, V. H., Anand, S., Tran, M., Kanneganti, A., Vasudevan, S., Seifert, J. L., Cheng, J., Keefer, E. W., & Romero-Ortega, M. I. (2014) · 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2014.6944000 · Cited by 19
Wu, J., Zhang, Y., Zhang, X., Lin, Z., & Li, G. (2022) · Frontiers in Molecular Neuroscience · doi:10.3389/fnmol.2022.938930 · Cited by 22
“, 2021), originally designed for intelligent prosthetic control, have emerged as a treatment option for neuromas (Kung et al., 2013; Urbanchek et al., 2016; Vu et al., 2018).”
BackgroundBidirectional bionic limbs: a perspective bridging technology and physiology
Pasluosta, C. F., Kiele, P., Čvančara, P., Micera, S., Aszmann, O. C., & Stieglitz, T. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac4bff · Cited by 17
Regenerative peripheral nerve interfaces (RPNIs): current status and future direction
Burke, K. L., Kung, T. A., Hooper, R. C., Kemp, S. W. P., & Cederna, P. S. (2022) · Plastic and Aesthetic Research · doi:10.20517/2347-9264.2022.26 · Cited by 15
Self-citationExperimental nerve transfer model in the rat forelimb
Bergmeister, K. D., Aman, M., Riedl, O., Manzano-Szalai, K., Sporer, M. E., Salminger, S., & Aszmann, O. C. (2016) · European surgery. Supplement/European surgery · doi:10.1007/s10353-016-0386-4 · Cited by 15
“Clinical studies have shown that nerve transfers provide exceptional outcomes in terms of regeneration [9, 10], but limited quantities of donor nerves sometimes prevent better overall extremity function [11].”
BackgroundOn the development of optical peripheral nerve interfaces
Anderson, H., & Weir, R. F. (2019) · Neural Regeneration Research · doi:10.4103/1673-5374.245461 · Cited by 14
“…extraneural electrodes (best represented by cuff electrodes, but also including helical and button type), intraneural (the most widely used being intrafascicular) electrodes and sieve (or regenerative) electrodes [reviewed in Navarro et al. (2005), Grill et al. (2009), and Kung et al. (2013)].”
BackgroundGonzález-Prieto, J., Cristóbal, L., Arenillas, M., Giannetti, R., Frías, J. D. M., Rivas, E. A., Barbero, E. S., Gutiérrez-Pecharromán, A., Montero, F. D., & Maldonado, A. A. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25021141 · Cited by 15
Public’s Knowledge and Attitudes Toward Vascularized Composite Allotransplantation and Donation
Denadai, R., Araujo, K. C., Pinho, A. S., Denadai, R., Araujo, G. H., & Raposo-Amaral, C. E. (2016) · Aesthetic Plastic Surgery · doi:10.1007/s00266-016-0623-z · Cited by 13
Губин, А. В., Кузнецов, В. П., Borzunov, D. Y., Анатольевич, К. А., Reznik, A. V., & Юрьевич, Ч. А. (2016) · Biomedical Engineering · doi:10.1007/s10527-016-9639-6 · Cited by 13
Karczewski, A. M., Dingle, A. M., & Poore, S. O. (2021) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2021.711028 · Cited by 13
Selective stimulation of facial muscles with a penetrating electrode array in the feline model
Sahyouni, R., Bhatt, J. M., Djalilian, H. R., Tang, W. C., Middlebrooks, J. C., & Lin, H. W. (2016) · The Laryngoscope · doi:10.1002/lary.26078 · Cited by 11
“Notably, detection of patientinitiated electrical neural or myogenic signals that subsequently deliver messages to and activate a secondary device has been an area of recent and considerable interest, particularly in military research laboratories to address the needs of veteran amputees and improve the functionality…”
BackgroundLower Extremity Allotransplantation: Are We Ready for Prime Time?
Swanson, E. W., Cheng, H.-T., Lough, D., Lee, W. P. A., Shores, J. T., & Brandacher, G. (2015) · Vascularized Composite Allotransplantation · doi:10.1080/23723505.2015.1123798 · Cited by 13
“Myoelectric prosthetics offer a high degree of freedom of movement using robotic technology coupled to electromyographic signals generated over target muscles.(33) The limiting step in applying myoelectric prosthetics more widely is harnessing specific, accurate, and long-lasting input.”
BackgroundKelley, M. A., Benz, H. L., Engdahl, S. M., & Bridges, J. F. P. (2019) · Expert Review of Medical Devices · doi:10.1080/17434440.2019.1626231 · Cited by 13
A World Update of Progress in Lower Extremity Transplantation: What’s Hot and What’s Not
Kodali, N. A., Ramu, J., Sazoglu, B., Demir, Z., Dirican, O. F., Zor, F., Külahçı, Y., & Gorantla, V. S. (2024) · Annals of Plastic Surgery · doi:10.1097/sap.0000000000004035 · Cited by 11
“37 By using concerned nerves to power the concerned muscles that are intuitive to the robotic prosthetic (eg, radial nerve extending the wrist and fingers), targeted muscle reinnervation can generate more inputs.”
BackgroundMethodToward Natural Limb Function: A New Era in Prosthetic Innovation
Tian, Y., Wallace, D. M., Cederna, P. S., Chestek, C. A., & Kemp, S. W. P. (2025) · Annals of Neurology · doi:10.1002/ana.27287 · Cited by 8
Self-citationMerging Humans and Neuroprosthetics through Regenerative Peripheral Nerve Interfaces
Tian, Y., Vaskov, A. K., Adidharma, W., Cederna, P. S., & Kemp, S. W. P. (2024) · Seminars in Plastic Surgery · doi:10.1055/s-0044-1779028 · Cited by 8
“30 Regaining limb functions also hinges on the provision and integration of sensory feedback, which is crucial for users to feel that the neuroprosthesis is part of their body (i.e., device embodiment).”
BackgroundSelf-citationOptimizing Surgical Outcomes and the Role of Preventive Surgery: A Scoping Review
Cauley, R. P., Rahmani, B., Adebagbo, O. D., Park, J. B., Garvey, S. R., Chen, A., Nickman, S., Tobin, M. J., Valentine, L., Weidman, A. A., et al. (2024) · Journal of Reconstructive Microsurgery · doi:10.1055/a-2331-7885 · Cited by 3
“50 While both TMR and RPNI have demonstrated signi fi cant promise when used as preventive surgical treatments, their indications and applications in surgical procedures are still on the rise.”
Tham, J.-L., Sood, A., Saffari, T. M., & Khajuria, A. (2022) · European Journal of Plastic Surgery · doi:10.1007/s00238-022-02021-5 · Cited by 3
“In this technique, free muscle grafts are transferred to and wrapped circumferentially around the amputated stump and its transected nerve fascicular units [55, 56].”
MethodNew surgical options to improve the quality of life of amputees
Kang, N., Woollard, A., & Konczalik, W. (2019) · Surgery (Oxford) · doi:10.1016/j.mpsur.2019.02.007 · Cited by 3
Umansky, D., Elzinga, K. E., & Midha, R. (2024) · Handbook of clinical neurology · doi:10.1016/b978-0-323-90108-6.00012-0 · Cited by 2
ROBERTS, J. M., Lin, I. C., & Levin, L. S. (2021) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000008003 · Cited by 2
Complete regenerative peripheral nerve interfaces, fatigue and recovery
French, Z. P., Mays, E. A., Hassett, C. A., Moon, J. D., Langhals, N. B., Cederna, P. S., & Urbanchek, M. G. (2014) · IEEE Signal Processing in Medicine and Biology Symposium · doi:10.1109/spmb.2014.7002970 · Cited by 2
Self-citationMarkewych, A., Hansdorfer, M., Blank, A. T., Kokosis, G., & Kurlander, D. E. (2023) · Techniques in Hand and Upper Extremity Surgery · doi:10.1097/bth.0000000000000424 · Cited by 2
History of Plastic Surgery and General Concepts of Reconstruction
Khurram, M. F. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-82394-4.00001-x · Cited by 1
Satkunabalan, M., Tay, J. Q., & Ng, Z. Y. (2024) · European Journal of Plastic Surgery · doi:10.1007/s00238-024-02225-x · Cited by 1
“…with high recurrence rates [9] and result in complications such as long-term dependence on medications with their attendant side effects [4–7 Recent studies have shown that the regenerative peripheral nerve interface (RPNI) is a novel option for preventing or treating neuromas [7, 11, 12].”
Current and Future Directions for Upper Extremity Amputations
Best, C. S. W., & Kung, T. A. (2024) · Clinics in Plastic Surgery · doi:10.1016/j.cps.2024.05.001 · Cited by 2
Self-citationEmergence of Nerve Interfaces with Robotic Applications
Burke, K. L., Dumanian, G. A., & Cederna, P. S. (2024) · Springer eBooks · doi:10.1007/978-3-031-57132-9_6 · Cited by 1
Self-citationKloehn, A. J., Errante, E. L., Costello, M. C., & Burks, S. S. (2023) · Neurosurgery · doi:10.1227/neu.0000000000002567 · Cited by 1
Commentary on “The Utility of Hand Transplantation in Hand Amputee Patients”
Sears, E. D., & Chung, K. C. (2014) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2014.10.011
Is Lower Extremity Transplantation a Superior Alternative to Prostheses? No—At Least Not Yet
Grimm, P. D., Tintle, S. M., Potter, B. K., & Elster, E. A. (2018) · Current Transplantation Reports · doi:10.1007/s40472-018-0217-6
Kumar, N. G., Cederna, P. S., & Kung, T. A. (2021) · Techniques in Orthopaedics · doi:10.1097/bto.0000000000000542
“These approaches are classified by the interface site and include: (1) residual muscle groups, (2) the central nervous system, and (3) the peripheral nervous system.”
BackgroundSelf-citationRealizing Upper Extremity Bionic Limbs: Leveraging Neuroprosthetic Control Strategies
Kumar, N. G., Chestek, C. A., Cederna, P. S., & Kung, T. A. (2023) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000011183
“2,23,26 This has led to continued abandonment of myoelectric controlled prostheses.”
Self-citationTemel Spinal Enstrüman Bilgisi
Kayalar, A. E., Naderi, S., Özhan, B. B., Kılınçer, C., Ferrara, L., Atik, E., Temiz, P., Aydın, H. E., Akkaya, D., Arslantaş, A., et al. (2023) · Akademisyen Kitabevi eBooks · doi:10.37609/akya.2638
Baranwal, N., Menville, J. E., Persad‐Paisley, E. M., Sobti, N., & Kalliainen, L. K. (2024) · PubMed Central · Cited by 2
Preciado, J. D. M., Gámiz, D. G., Royo, M., & Hontanilla, B. (2026) · PLoS ONE · doi:10.1371/journal.pone.0350845
A Theoretical Graph Analysis on EEG-Controlled Bionic Arm with Importance to Senses of Human
Kaviarasu, A., & Arul, S. M. (2025) · Springer proceedings in mathematics & statistics · doi:10.1007/978-3-031-77764-6_33
Avoiding a Vanilla Transhumeral Amputation
Dearden, M. E., & Potter, B. K. (2026) · Hand Clinics · doi:10.1016/j.hcl.2026.03.004
Georgieva, G., Dzokikj, G., Gramatnikovski, N., Srbov, B., Nikolovska, B., Redzepi, M., Atanasova, A., & Pejkova, S. (2026) · PRILOZI · doi:10.2478/prilozi-2026-0023
Metadata
- Authors
- Kung, T. A., Bueno, R. A., Alkhalefah, G. K., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S.
- Affiliations
- University of Michigan (US)
- Michigan Medicine (US)
- SIU Medicine (US)
- Southern Illinois University Carbondale (US)
- Venue
- Plastic and Reconstructive Surgery
- Published
- 2013-12
- Volume
- 132
- Issue
- 6
- Pages
- 1515-1523
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2028659107
- Cited by
- 71
- References
- 74
- Citations by year
- 2026: 3 · 2025: 2 · 2024: 10 · 2023: 6 · 2022: 5 · 2021: 7 · 2020: 4 · 2019: 4 · 2018: 4 · 2017: 5 · 2016: 8 · 2015: 4 · 2014: 9
- FWCI
- 0.66
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Plastic & Reconstructive Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Keywords
- upper limb prosthesis, targeted muscle reinnervation, brain-computer interface, peripheral nerve interfaces, neuroprosthetics, sensory feedback, upper limb amputation, motor control
- MeSH terms
- Afferent Pathways, Amputation, Surgical, Arm, Artificial Limbs, Efferent Pathways, Humans, Robotics, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.