CoChat

Innovations in Prosthetic Interfaces for the Upper Extremity

The DOI matches its Crossref record; 73 of the 74 references it cites were found in a registry or an index.

Abstract

Advancements in modern robotic technology have led to the development of highly sophisticated upper extremity prosthetic limbs. High-fidelity volitional control of these devices is dependent on the critical interface between the patient and the mechanical prosthesis. Recent innovations in prosthetic interfaces have focused on several control strategies. Targeted muscle reinnervation is currently the most immediately applicable prosthetic control strategy and is particularly indicated in proximal upper extremity amputations. Investigation into various brain interfaces has allowed acquisition of neuroelectric signals directly or indirectly from the central nervous system for prosthetic control. Peripheral nerve interfaces permit signal transduction from both motor and sensory nerves with a higher degree of selectivity. This article reviews the current developments in each of these interface systems and discusses the potential of these approaches to facilitate motor control and sensory feedback in upper extremity neuroprosthetic devices.

Overview

Integrity signals

Registry

Crossref · 10.1097/prs.0b013e3182a97e5f

Cites

73 of 73 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 5

  1. Freeland, 2007, Orthopedics, 30, 120, 10.3928/01477447-20070201-16 · doi:10.3928/01477447-20070201-16
  2. Tenore, 2011, Johns Hopkins APL Tech Dig, 30, 230
  3. Kipke, 2004, Conf Proc IEEE Eng Med Biol Soc, 7, 5344
  4. Slot, 1997, Artif Organs, 21, 207
  5. Park, 2009, Conf Proc IEEE Eng Med Biol Soc, 2009, 6789

Cited by

See all 71

Metadata

Authors
Kung, T. A., Bueno, R. A., Alkhalefah, G. K., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S.
Affiliations
  • University of Michigan (US)
  • Michigan Medicine (US)
  • SIU Medicine (US)
  • Southern Illinois University Carbondale (US)
Venue
Plastic and Reconstructive Surgery
Published
2013-12
Volume
132
Issue
6
Pages
1515-1523
ISSN
0032-1052 (ISSN-L)
OpenAlex
W2028659107
Cited by
71
References
74
Citations by year
2026: 3 · 2025: 2 · 2024: 10 · 2023: 6 · 2022: 5 · 2021: 7 · 2020: 4 · 2019: 4 · 2018: 4 · 2017: 5 · 2016: 8 · 2015: 4 · 2014: 9
FWCI
0.66
Type
journal article
Language
en
Open access
closed
Locations
  • Plastic & Reconstructive Surgery (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
Keywords
upper limb prosthesis, targeted muscle reinnervation, brain-computer interface, peripheral nerve interfaces, neuroprosthetics, sensory feedback, upper limb amputation, motor control
MeSH terms
Afferent Pathways, Amputation, Surgical, Arm, Artificial Limbs, Efferent Pathways, Humans, Robotics, Brain-Computer Interfaces

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.