CoChat

Differential Computed Tomographic Attenuation of Metabolically Active and Inactive Adipose Tissues: Preliminary Findings

Open access
Hu, Houchun Harry, Chung, Sandra A., Nayak, Krishna S., Jackson, Hollie A., Gilsanz, Vicente · 2011 · Journal of Computer Assisted Tomography
Cited by 76

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

This study investigates differences in computed tomography Hounsfield units between metabolically active (brown fat) and inactive adipose tissues (white fat) due to variations in their densities. Positron emission and computed tomographic data from 101 pediatric and adolescent patients were analyzed. Regions of metabolically active and inactive adipose tissues were identified, and standard uptake values and Hounsfield units were measured. Hounsfield units of active brown fat were more positive (P < 0.001) than inactive fat (-62.4 ± 5.3 vs -86.7 ± 7.0) and the difference was observed in both males and females.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/rct.0b013e3181fc2150

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Hu, H. H., Chung, S. A., Nayak, K. S., Jackson, H. A., & Gilsanz, V.
Venue
Journal of Computer Assisted Tomography
Published
2011-01
Volume
35
Issue
1
Pages
65-71
ISSN
0363-8715 (ISSN-L)
OpenAlex
W2047124930
Cited by
76
References
10
FWCI
3.27
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.