The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
T1 Relaxivities of Gadolinium-Based Magnetic Resonance Contrast Agents in Human Whole Blood at 1.5, 3, and 7 T
Open accessAbstract
OBJECTIVES: Calculation of accurate T1 relaxivity (r1) values for gadolinium-based magnetic resonance contrast agents (GBCAs) is a complex process. As such, often referenced r1 values for the GBCAs at 1.5 T, 3 T, and 7 T are based on measurements obtained in media that are not clinically relevant, derived from only a small number of concentrations, or available for only a limited number of GBCAs. This study derives the r1 values of the 8 commercially available GBCAs in human whole blood at 1.5 T, 3 T, and 7 T. MATERIALS AND METHODS: Eight GBCAs were serially diluted in human whole blood, at 7 concentrations from 0.0625 to 4 mM. A custom-built phantom held the dilutions in air-tight cylindrical tubes maintained at 37 ± 0.5°C by a heat-circulating system. Images were acquired using inversion recovery sequences with inversion times from 30 milliseconds to 10 seconds at 1.5 T and 3 T as well as 60 milliseconds to 5 seconds at 7 T. A custom MATLAB program was used to automate signal intensity measurements from the images acquired of the phantom. SigmaPlot was used to calculate T1 relaxation times and, finally, r1. RESULTS: Measured r1 values in units of s⁻¹·mM⁻¹ at 1.5 T (3 T/7 T) were 3.9 ± 0.2 (3.4 ± 0.4/2.8 ± 0.4) for Gd-DOTA, 4.6 ± 0.2 (4.5 ± 0.3/4.2 ± 0.3) for Gd-DO3A-butrol, 4.3 ± 0.4 (3.8 ± 0.2/3.1 ± 0.4) for Gd-DTPA, 6.2 ± 0.5 (5.4 ± 0.3/4.7 ± 0.1) for Gd-BOPTA, 4.5 ± 0.1 (3.9 ± 0.2/3.7 ± 0.2) for Gd-DTPA-BMA, 4.4 ± 0.2 (4.2 ± 0.2/4.3 ± 0.2) for Gd-DTPA-BMEA, 7.2 ± 0.2 (5.5 ± 0.3/4.9 ± 0.1) for Gd-EOB-DTPA, and 4.4 ± 0.6 (3.5 ± 0.6/3.4 ± 0.1) for Gd-HP-DO3A. The agents can be stratified by relaxivity, with a significant additional dependency on field strength. CONCLUSIONS: This report quantifies, for the first time, T1 relaxivity for all 8 gadolinium chelates in common clinical use worldwide, at current relevant field strengths, in human whole blood at physiological temperature (37°C). The measured r1 values differ to a small degree from previously published values, where such comparisons exist, with the current r1 measurements being that most relevant to clinical practice. The macrocyclic agents, with the exception of Gd-DO3A-butrol, have slightly lower r1 values when compared with the 2 much less stable linear agents, Gd-DTPA-BMA and Gd-DTPA-BMEA. The 2 agents with hepatobiliary excretion, Gd-EOB-DTPA and Gd-BOPTA, have, at 1.5 and 3 T, substantially higher r1 values than all other agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rohrer, M., Bauer, H., Mintorovitch, J., Requardt, M., & Weinmann, H.-J. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000184756.66360.d3 · Cited by 1,682
Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
Lu, H., Clingman, C., Golay, X., & van Zijl, P. C. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20178 · Cited by 685
MS-325: albumin-targeted contrast agent for MR angiography.
Lauffer, R. B., Parmelee, D. J., Dunham, S. U., Ouellet, H. S., Dolan, R. P., Witte, S., McMurry, T. J., & Walovitch, R. C. (1998) · Radiology · doi:10.1148/radiology.207.2.9577506 · Cited by 457
Laurent, S., Elst, L. V., & Muller, R. N. (2006) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.100 · Cited by 441
Pintaske, J., Martirosian, P., Graf, H., Erb, G., Lodemann, K.-P., Claussen, C. D., & Schick, F. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000197668.44926.f7 · Cited by 383
MRI contrast agents: Basic chemistry and safety
Hao, D., Ai, T., Goerner, F., Hu, X., Runge, V. M., & Tweedle, M. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23725 · Cited by 336
Self-citationGd-DTPA relaxivity depends on macromolecular content
Stanisz, G. J., & Henkelman, R. M. (2000) · Magnetic Resonance in Medicine · Cited by 212
Determination of blood longitudinal relaxation time (T1) at high magnetic field strengths
Dobre, M. C., Uǧurbil, K., & Marjańska, M. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2006.10.020 · Cited by 141
Blockley, N. P., Jiang, L., Gardener, A. G., Ludman, C. N., Francis, S., & Gowland, P. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21792 · Cited by 140
Giesel, F. L., von Tengg‐Kobligk, H., Wilkinson, I. D., Siegler, P., der Lieth, C. W. V., Frank, M., Lodemann, K. P., & Essig, M. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000192421.81037.d5 · Cited by 117
Cited by
Organic Phase Syntheses of Magnetic Nanoparticles and Their Applications
Wu, L., Mendoza-Garcia, A., Li, Q., & Sun, S. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00687 · Cited by 601
Zhang, L., Wan, S.-S., Li, C.-X., Xu, L., Cheng, H., & Zhang, X.-Z. (2018) · Nano Letters · doi:10.1021/acs.nanolett.8b03178 · Cited by 584
Liu, T., Zhang, M., Liu, W., Zeng, X., Song, X., Yang, X., Zhang, X., & Feng, J. (2018) · ACS Nano · doi:10.1021/acsnano.8b01456 · Cited by 515
Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging
Christodoulou, A. G., Shaw, J. L., Nguyen, C., Yang, Q., Xie, Y., Wang, N., & Li, D. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0217-y · Cited by 323
Epelbaum, S., Burgos, N., Canney, M., Matthews, D., Houot, M., Santin, M. D., Desseaux, C., Bouchoux, G., Stroer, S., Martin, C., et al. (2022) · Alzheimer's Research & Therapy · doi:10.1186/s13195-022-00981-1 · Cited by 72
Metadata
- Authors
- Shen, Y., Goerner, F. L., Snyder, C., Morelli, J. N., Hao, D., Hu, D., Li, X., & Runge, V. M.
- Venue
- Investigative Radiology
- Published
- 2015-05
- Volume
- 50
- Issue
- 5
- Pages
- 330-338
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2320879921
- Cited by
- 257
- References
- 15
- FWCI
- 8.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: T1 Relaxivities of Gadolinium-Based Magnetic Resonance Contrast Agents in Human Whole Blood at 1.5, 3, and 7 T. https://app.cochat.ai/papers/10.1097/rli.0000000000000132
- The paper
- Shen, Y., Goerner, F. L., Snyder, C., Morelli, J. N., Hao, D., Hu, D., Li, X., & Runge, V. M. (2015). T1 Relaxivities of Gadolinium-Based Magnetic Resonance Contrast Agents in Human Whole Blood at 1.5, 3, and 7 T. Investigative Radiology. https://doi.org/10.1097/rli.0000000000000132
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.