Histology and Gadolinium Distribution in the Rodent Brain After the Administration of Cumulative High Doses of Linear and Macrocyclic Gadolinium-Based Contrast Agents
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Objectives: Retrospective studies in patients with primary brain tumors or other central nervous system pathologies as well as postmortem studies have suggested that gadolinium (Gd) deposition occurs in the dentate nucleus (DN) and globus pallidus (GP) after multiple administrations of primarily linear Gd-based contrast agents (GBCAs). However, this deposition has not been associated with any adverse effects or histopathological alterations. The aim of this preclinical study was to systematically examine differences between linear and macrocyclic GBCAs in their potential to induce changes in brain and skin histology including Gd distribution in high spatial resolution. Materials and Methods: Fifty male Wistar-Han rats were randomly allocated into control (saline, n = 10 rats) and 4 GBCA groups (linear GBCAs: gadodiamide and gadopentetate dimeglumine, macrocyclic GBCAs: gadobutrol and gadoteridol; n = 10 rats per group). The animals received 20 daily intravenous injections at a dose of 2.5 mmol Gd/kg body weight. Eight weeks after the last GBCA administration, the animals were killed, and the brain and skin samples were histopathologically assessed (hematoxylin and eosin; cresyl violet [Nissl]) and by immunohistochemistry. The Gd concentration in the skin, bone, brain, and skeletal muscle samples were analyzed using inductively coupled plasma mass spectroscopy (ICP-MS, n = 4). The spatial Gd distribution in the brain and skin samples was analyzed in cryosections using laser ablation coupled with ICP-MS (LA-ICP-MS, n = 3). For the ultra-high resolution of Gd distribution, brain sections of rats injected with gadodiamide or saline (n = 1) were assessed by scanning electron microscopy coupled to energy dispersive x-ray spectroscopy and transmission electron microscopy, respectively. Results: No histological changes were observed in the brain. In contrast, 4 of 10 animals in the gadodiamide group but none of the animals in other groups showed macroscopic and histological nephrogenic systemic fibrosis–like skin lesions. The Gd concentrations observed in the skin/brain samples (in nanomole Gd per gram of tissue) for each agent were as follows: gadodiamide: 1472 ± 115/11.1 ± 5.1, gadopentetate dimeglumine: 80.8 ± 6.2/13.1 ± 7.3, gadobutrol: 1.1 ± 0.5/0.7 ± 0.4, and gadoteridol: 1.7 ± 0.8/0.5 ± 0.2. The average detected residual Gd concentration in the brain was approximately 15-fold higher for linear than for macrocyclic GBCAs. The highest amounts of Gd found in brain corresponded to less than 0.0002% of the injected dose per gram of tissue. Using LA-ICP-MS, high Gd concentrations in the deep cerebellar nuclei and in the granular layer of the cerebellar cortex were detected only for linear gadodiamide and gadopentetate dimeglumine but not for gadoteridol or gadobutrol. The energy dispersive x-ray spectroscopy analysis revealed Gd-containing spots in the skin of animals administered gadodiamide and gadopentetate dimeglumine. Transmission electron microscopy revealed several Gd-containing spots in the region of the dentate nuclei in the brain of 1 animal injected with gadodiamide. Conclusions: After repeated high dosing, nephrogenic systemic fibrosis–like macroscopic and histopathological lesions of the skin were observed only in some of the gadodiamide-treated animals. No histopathological findings were detected in the rodent brain. The administration of linear GBCAs was associated with significantly higher Gd concentrations in the brain and skin compared with macrocyclic GBCA administration. The results of LA-ICP-MS demonstrated local accumulation of Gd within the deep cerebellar nuclei and the granular layer only after the administration of linear agents. In summary, the detected low Gd concentrations in the skin and brain were well correlated with the higher kinetic stability of macrocyclic GBCA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Embedding in Epoxy Resins for Ultrathin Sectioning in Electron Microscopy
Richardson, K. C., Jarett, L., & Finke, E. H. (1960) · Stain Technology · doi:10.3109/10520296009114754 · Cited by 3,295
The glymphatic system: a beginner's guide
Jessen, N. A., Munk, A. S. F., Lundgaard, I., & Nedergaard, M. (2015) · Neurochemical Research · doi:10.1007/s11064-015-1581-6 · Cited by 2,075 · cited 1×
“Iliff et al(47) showed that after intracisternal injection, GBCAs distribute along the glymphatic system, a so-called waste clearance system, from the basal artery to the olfactory artery (paravascular pathway), suggesting that GBCAs enter the brain through the exchange between cerebrospinal and interstitial fluid (CS…”
BackgroundStrategies for increasing the sensitivity of gadolinium based MRI contrast agents
Caravan, P. (2006) · Chemical Society Reviews · doi:10.1039/b510982p · Cited by 1,438
Intracranial gadolinium deposition after contrast-enhanced MR imaging
McDonald, R. J., McDonald, J. S., Kallmes, D. F., Jentoft, M. E., Murray, D. L., Thielen, K. R., Williamson, E. E., & Eckel, L. J. (2015) · Radiology · doi:10.1148/radiol.15150025 · Cited by 1,358 · cited 3×
“clinical data reporting the lack of apparent histological changes in H&E-stained sections of DN from rats and patients administered gadodiamide.(10,34) Despite the absence of obvious GBCA-mediated histopathological changes in the brain, varying Gd concentrations in the brain were measured using ICP-MS.”
BackgroundMethodKanda, T., Ishii, K., Kawaguchi, H., Kitajima, K., & Takenaka, D. (2014) · Radiology · doi:10.1148/radiol.13131669 · Cited by 1,339
Brain-wide pathway for waste clearance captured by contrast-enhanced MRI
Iliff, J. J., Lee, H., Yu, M., Feng, T., Logan, J., Nedergaard, M., & Benveniste, H. (2013) · Journal of Clinical Investigation · doi:10.1172/jci67677 · Cited by 1,148
Kanda, T., Fukusato, T., Matsuda, M., Toyoda, K., Oba, H., Kotoku, J., Haruyama, T., Kitajima, K., & Furui, S. (2015) · Radiology · doi:10.1148/radiol.2015142690 · Cited by 874
The dynamic blood–brain barrier
Keaney, J., & Campbell, M. (2015) · The FEBS Journal · doi:10.1111/febs.13412 · Cited by 616
Radbruch, A., Weberling, L. D., Kieslich, P. J., Eidel, O., Burth, S., Kickingereder, P., Heiland, S., Wick, W., Schlemmer, H.-P., & Bendszus, M. (2015) · Radiology · doi:10.1148/radiol.2015150337 · Cited by 561
Exposure, metabolism, and toxicity of rare earths and related compounds.
Hirano, S., & Suzuki, K. T. (1996) · Environmental Health Perspectives · doi:10.1289/ehp.96104s185 · Cited by 540
Stability of Gadolinium-Based Magnetic Resonance Imaging Contrast Agents in Human Serum at 37°C
Frenzel, T., Lengsfeld, P., Schirmer, H., Hütter, J., & Weinmann, H.-J. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e3181852171 · Cited by 539
Self-citationKanda, T., Osawa, M., Oba, H., Toyoda, K., Kotoku, J., Haruyama, T., Takeshita, K., & Furui, S. (2015) · Radiology · doi:10.1148/radiol.14140364 · Cited by 492
Thomsen, H. S., Morcos, S. K., Almén, T., Bellin, M.-F., Bertolotto, M., Bongartz, G., Clement, O., Leander, P., Heinz-Peer, G., Reimer, P., et al. (2013) · European Radiology · doi:10.1007/s00330-012-2597-9 · Cited by 441 · cited 2×
“While macrocyclic GBCAs are extremely stable and basically inert under physiological conditions,(2,6) linear GBCAs are characterized by a lower complex stability and are associated with NSF.(3,7)”
BackgroundErrante, Y., Cirimele, V., Mallio, C. A., Di Lazzaro, V., Zobel, B. B., & Quattrocchi, C. C. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000072 · Cited by 421
25 Years of Contrast-Enhanced MRI: Developments, Current Challenges and Future Perspectives
Lohrke, J., Frenzel, T., Endrikat, J., Alves, F. C., Grist, T. M., Law, M., Lee, J. M., Leiner, T., Li, K.-C., Nikolaou, K., et al. (2016) · Advances in Therapy · doi:10.1007/s12325-015-0275-4 · Cited by 420 · cited 1×
“With more than 460 million procedures pe formed to date, contrast-enhanced MRI is a well-established, safe, an valuable diagnostic imaging technique that is used worldwide.(1) Gad linium (Gd), dissociated from its ligand and present as a new Gd sp cies, can have adverse biological effects.”
Self-citationBest Practices Guideline: Toxicologic Histopathology
Crissman, J. W., Goodman, D. G., Hildebrandt, P. K., Maronpot, R. R., Prater, D. A., Riley, J. H., Seaman, W. J., & Thake, D. C. (2004) · Toxicologic Pathology · doi:10.1080/01926230490268756 · Cited by 347
Drug transport in brain via the cerebrospinal fluid.
Pardridge, W. M. (2011) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-8-7 · Cited by 316
Robert, P., Lehericy, S., Grand, S., Violas, X., Fretellier, N., Idée, J.-M., Ballet, S., & Corot, C. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000181 · Cited by 257
Ramalho, J., Castillo, M., AlObaidy, M., Nunes, R. H., Ramalho, M., Dale, B. M., & Semelka, R. C. (2015) · Radiology · doi:10.1148/radiol.2015150872 · Cited by 230
Robert, P., Violas, X., Grand, S., Lehericy, S., Idée, J.-M., Ballet, S., & Corot, C. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000241 · Cited by 212
Morcos, S. K. (2007) · The British Journal of Radiology · doi:10.1259/bjr/17111243 · Cited by 205
Sieber, M. A., Lengsfeld, P., Frenzel, T., Golfier, S., Schmitt-Willich, H., Siegmund, F., Walter, J., Weinmann, H.-J., & Pietsch, H. (2008) · European Radiology · doi:10.1007/s00330-008-0977-y · Cited by 203 · cited 2×
“While macrocyclic GBCAs are extremely stable and basically inert under physiological conditions,(2,6) linear GBCAs are characterized by a lower complex stability and are associated with NSF.(3,7)”
BackgroundSelf-citationRadbruch, A., Weberling, L. D., Kieslich, P. J., Hepp, J., Kickingereder, P., Wick, W., Schlemmer, H.-P., & Bendszus, M. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000227 · Cited by 201
Bolon, B., Garman, R. H., Pardo, I. D., Jensen, K., Sills, R. C., Roulois, A., Radovsky, A., Bradley, A., Andrews-Jones, L., Butt, M., et al. (2013) · Toxicologic Pathology · doi:10.1177/0192623312474865 · Cited by 191
Shamam, Y. M., & Jesús, O. D. (2021) · StatPearls · Cited by 189
Weberling, L. D., Kieslich, P. J., Kickingereder, P., Wick, W., Bendszus, M., Schlemmer, H.-P., & Radbruch, A. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000206 · Cited by 168
Runge, V. M. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000273 · Cited by 164
Cao, Y., Huang, D. Q., Shih, G., & Prince, M. R. (2016) · American Journal of Roentgenology · doi:10.2214/ajr.15.15327 · Cited by 162
Jost, G., Lenhard, D. C., Sieber, M. A., Lohrke, J., Frenzel, T., & Pietsch, H. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000242 · Cited by 158
Self-citationKaufmann, W. S. H., Bolon, B. N., Bradley, A., Butt, M. T., Czasch, S., Garman, R. H., George, C., Gröters, S., Krinke, G. J., Little, P. B., et al. (2012) · Toxicologic Pathology · doi:10.1177/0192623312439125 · Cited by 150
Jošt, G., Frenzel, T., Lohrke, J., Lenhard, D. C., Naganawa, S., & Pietsch, H. (2016) · European Radiology · doi:10.1007/s00330-016-4654-2 · Cited by 147
Self-citationLancelot, E. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000280 · Cited by 124
Gadolinium in Humans: A Family of Disorders
Semelka, R. C., Ramalho, M., AlObaidy, M., & Ramalho, J. (2016) · American Journal of Roentgenology · doi:10.2214/ajr.15.15842 · Cited by 124 · cited 1×
“However, several public tions do suggest a potential correlation.(19,20) At this time, none these publications provide any reasonable scientific evidence of causal association.”
Self-reported gadolinium toxicity: A survey of patients with chronic symptoms
Burke, L. M. B., Ramalho, M., AlObaidy, M., Chang, E., Jay, M., & Semelka, R. C. (2016) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.05.005 · Cited by 109 · cited 1×
“However, several public tions do suggest a potential correlation.(19,20) At this time, none these publications provide any reasonable scientific evidence of causal association.”
Smith, A. P. L., Marino, M., Roberts, J. C., Crowder, J. M., Castle, J. W., Lowery, L., Morton, C., Hibberd, M. G., & Evans, P. M. (2016) · Radiology · doi:10.1148/radiol.2016160905 · Cited by 99
Xue, S., Yang, H., Qiao, J., Pu, F., Jiang, J., Hubbard, K., Hekmatyar, K., Langley, J. A., Salarian, M., Long, R. C., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1423021112 · Cited by 87
M‐M, P., Weiskirchen, R., Gaßler, N., Bosserhoff, A., & Becker, J. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0058702 · Cited by 79
Kartamihardja, A. A. P., Nakajima, T., Kameo, S., Koyama, H., & Tsushima, Y. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000295 · Cited by 69
Transferrin-Coated Gadolinium Nanoparticles as MRI Contrast Agent
Korkusuz, H., Ulbrich, K., Welzel, K., Koeberle, V., Watcharin, W., Bahr, U., Chernikov, V. P., Knobloch, T., Petersen, S., Huebner, F., et al. (2012) · Molecular Imaging and Biology · doi:10.1007/s11307-012-0579-6 · Cited by 54
Kartamihardja, A. A. P., Nakajima, T., Kameo, S., Koyama, H., & Tsushima, Y. (2016) · British Journal of Radiology · doi:10.1259/bjr.20160509 · Cited by 48
IMAGENA: Image Generation and Analysis – An interactive software tool handling LA-ICP-MS data
Osterholt, T., Salber, D., Matusch, A., Becker, J. S., & Palm, C. (2011) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2011.03.010 · Cited by 44
Taupitz, M., Stolzenburg, N., Ebert, M., Schnorr, J., Hauptmann, R., Kratz, H., Hamm, B., & Wagner, S. (2012) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.1500 · Cited by 42
Boaru, S. G., Merle, U., Uerlings, R., Zimmermann, A., Weiskirchen, S., Matusch, A., Stremmel, W., & Weiskirchen, R. (2014) · BMC Neuroscience · doi:10.1186/1471-2202-15-98 · Cited by 40
Neef, N., Nikula, K. J., Francke‐Carroll, S., & Boone, L. I. (2012) · Toxicologic Pathology · doi:10.1177/0192623312438737 · Cited by 34
Runge, V. M. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000182 · Cited by 33
Current status review: cerebral amyloid.
Duchen, L. W. (1992) · Europe PMC (PubMed Central) · Cited by 18
Exceeding the Limits of the Normal Blood-Brain Barrier: Quo Vadis Gadolinium?
Levy, L. M. (2007) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0725 · Cited by 9
Cited by
Gadolinium Deposition in the Brain: Current Updates
Choi, J. W., & Moon, W.-J. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2018.0356 · Cited by 183
“Recent preclinical studies have also reported that the gadolinium concentration was highest in the olfactory bulb after both the linear and macrocyclic agent exposures (58, 68).”
BackgroundInfluential
Metadata
- Authors
- Lohrke, J., Frisk, A.-L., Frenzel, T., Schöckel, L., Rosenbruch, M., Jost, G., Lenhard, D. C., Sieber, M. A., Nischwitz, V., Küppers, A., & Pietsch, H.
- Venue
- Investigative Radiology
- Published
- 2017-06
- Volume
- 52
- Issue
- 6
- Pages
- 324-333
- ISSN
- 0020-9996 (ISSN-L)
- 1536-0210
- OpenAlex
- W2598964561
- Cited by
- 181
- References
- 47
- FWCI
- 11.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.