The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Near-field microscopy by elastic light scattering from a tip
Abstract
We describe ultraresolution microscopy far beyond the classical Abbe diffraction limit of one half wavelength (lambda/2), and also beyond the practical limit (ca. lambda/10) of aperture-based scanning near-field optical microscopy (SNOM). The 'apertureless' SNOM discussed here uses light scattering from a sharp tip (hence scattering-type or s-SNOM) and has no lambda-related resolution limit. Rather, its resolution is approximately equal to the radius a of the probing tip (for commercial tips, a < 20 nm) so that 10 nm is obtained in the visible (lambda/60). A resolution of lambda/500 has been obtained in the mid-infrared at lambda = 10 microm. The advantage of infrared, terahertz and even microwave illumination is that specific excitations can be exploited to yield specific contrast, e.g. the molecular vibration offering a spectroscopic fingerprint to identify chemical composition. S-SNOM can routinely acquire simultaneous amplitude and phase images to obtain information on refractive and absorptive properties. Plasmon- or phonon-resonant materials can be highlighted by their particularly high near-field signal level. Furthermore, s-SNOM can map the characteristic optical eigenfields of small, optically resonant particles. Lastly, we describe theoretical modelling that explains and predicts s-SNOM contrast on the basis of the local dielectric function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Absorption and Scattering of Light by Small Particles
Bohren, C. F., & Huffman, D. R. (1998) · doi:10.1002/9783527618156 · Cited by 18,474
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Optical Properties of Metal Clusters
Kreibig, U., & Vollmer, M. (1995) · Springer Series in Materials Science · doi:10.1007/978-3-662-09109-8 · Cited by 7,896
Single Molecule Detection Using Surface-Enhanced Raman Scattering (SERS)
Kneipp, K., Wang, Y., Kneipp, H., Perelman, L. T., Itzkan, I., Dasari, R. R., & Feld, M. S. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.1667 · Cited by 6,816
Faist, J., Capasso, F., Sivco, D. L., Sirtori, C., Hutchinson, A. L., & Cho, A. Y. (1994) · Science · doi:10.1126/science.264.5158.553 · Cited by 4,552
Spectroscopy of Single Hemoglobin Molecules by Surface Enhanced Raman Scattering
Xu, H., Bjerneld, E. J., Käll, M., & Börjesson, L. (1999) · Physical Review Letters · doi:10.1103/physrevlett.83.4357 · Cited by 2,362
Optical stethoscopy: Image recording with resolution λ/20
Pohl, D. W., Denk, W., & Lanz, M. (1984) · Applied Physics Letters · doi:10.1063/1.94865 · Cited by 2,040
Nanoscale chemical analysis by tip-enhanced Raman spectroscopy
Stöckle, R. M., Suh, Y. D., Deckert, V., & Zenobi, R. (2000) · Chemical Physics Letters · doi:10.1016/s0009-2614(99)01451-7 · Cited by 1,606
Breaking the Diffraction Barrier: Optical Microscopy on a Nanometric Scale
Betzig, E., Trautman, J. K., Harris, T. D., Weiner, J. S., & Kostelak, R. L. (1991) · Science · doi:10.1126/science.251.5000.1468 · Cited by 1,534
Near-field probing of vibrational absorption for chemical microscopy
Knoll, B., & Keilmann, F. (1999) · Nature · doi:10.1038/20154 · Cited by 926
Self-citationHigh-Resolution Near-Field Raman Microscopy of Single-Walled Carbon Nanotubes
Hartschuh, A., Sánchez, E. J., Xie, X., & Novotný, L. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.095503 · Cited by 870
Phonon-enhanced light–matter interaction at the nanometre scale
Hillenbrand, R., Taubner, T., & Keilmann, F. (2002) · Nature · doi:10.1038/nature00899 · Cited by 844
Self-citationScanning near-field optical microscopy with aperture probes: Fundamentals and applications
Hecht, B., Sick, B., Wild, U. P., Deckert, V., Zenobi, R., Martin, O. J. F., & Pohl, D. W. (2000) · The Journal of Chemical Physics · doi:10.1063/1.481382 · Cited by 761
Development of a 500 Å spatial resolution light microscope
Lewis, A., Isaacson, M., Harootunian, A., & Muray, A. (1984) · Ultramicroscopy · doi:10.1016/0304-3991(84)90201-8 · Cited by 757
Scanning Interferometric Apertureless Microscopy: Optical Imaging at 10 Angstrom Resolution
Zenhausern, F., Martin, Y., & Wickramasinghe, H. K. (1995) · Science · doi:10.1126/science.269.5227.1083 · Cited by 692
Enhanced dielectric contrast in scattering-type scanning near-field optical microscopy
Knoll, B., & Keilmann, F. (2000) · Optics Communications · doi:10.1016/s0030-4018(00)00826-9 · Cited by 510
Self-citationAravind, P. K., & Metiu, H. I. (1983) · Surface Science · doi:10.1016/0039-6028(83)90806-3 · Cited by 268
Inverting dynamic force microscopy: From signals to time-resolved interaction forces
Stark, M., Stark, R. W., Heckl, W. M., & Guckenberger, R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.122040599 · Cited by 213
Bonvalet, A., Joffre, M., Martin, J. L., & Migus, A. (1995) · Applied Physics Letters · doi:10.1063/1.114838 · Cited by 191
Coherent time-domain far-infrared spectroscopy
Auston, D. H., & Cheung, K. P. (1985) · Journal of the Optical Society of America B · doi:10.1364/josab.2.000606 · Cited by 145
Infrared conductivity mapping for nanoelectronics
Knoll, B., & Keilmann, F. (2000) · Applied Physics Letters · doi:10.1063/1.1330756 · Cited by 89
Self-citation
Cited by
Enhancement and Quenching of Single-Molecule Fluorescence
Anger, P., Bharadwaj, P., & Novotny, L. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.113002 · Cited by 3,158
Controlling the Synthesis and Assembly of Silver Nanostructures for Plasmonic Applications
Rycenga, M., Cobley, C. M., Zeng, J., Li, W., Moran, C. H., Zhang, Q., Qin, D., & Xia, Y. (2011) · Chemical Reviews · doi:10.1021/cr100275d · Cited by 2,828
Optical nano-imaging of gate-tunable graphene plasmons
Chen, J., Badioli, M., Alonso-González, P., Thongrattanasiri, S., Huth, F., Osmond, J., Spasenović, M., Centeno, A., Pesquera, A., Godignon, P., et al. (2012) · Nature · doi:10.1038/nature11254 · Cited by 2,107
Self-citationMott Transition in VO 2 Revealed by Infrared Spectroscopy and Nano-Imaging
Qazilbash, M. M., Brehm, M., Chae, B.-G., Ho, P.-C., Andreev, G. O., Kim, B.-J., Yun, S. J., Balatsky, A. V., Maple, M. B., Keilmann, F., et al. (2007) · Science · doi:10.1126/science.1150124 · Cited by 1,539
Self-citationGiannini, V., Fernández-Domínguez, A. I., Heck, S. C., & Maier, S. A. (2011) · Chemical Reviews · doi:10.1021/cr1002672 · Cited by 1,474
Metadata
- Authors
- Keilmann, F., & Hillenbrand, R.
- Venue
- Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences
- Publisher
- The Royal Society
- Published
- 2004-04-15
- Volume
- 362
- Issue
- 1817
- Pages
- 787-805
- ISSN
- 1364-503X (ISSN-L)
- 1471-2962
- OpenAlex
- W1481377485
- Cited by
- 705
- References
- 21
- FWCI
- 11.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.