CoChat

Can N95 respirators be reused after disinfection? And for how many times?

Open access

Preprint — published as 10.1021/acsnano.0c03597 · Paper page

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.

Abstract

The Coronavirus Disease 2019 (COVID-19) pandemic has led to a major shortage of N95 respirators, which are essential to protecting healthcare professionals and the general public who may come into contact with the virus. Thus, it is essential to determine how we can reuse respirators and other personal protection in these urgent times. We investigated multiple commonly used and easily deployable, scalable disinfection schemes on media with particle filtration efficiency of 95%. Among these, heating (≤85 °C) under various humidities (≤100% RH) was the most promising, nondestructive method for the preservation of filtration properties in meltblown fabrics as well as N95-grade respirators. Heating can be applied up to 50 cycles (85 °C, 30% RH) without observation in the degradation of meltblown filtration performance. Ultraviolet (UV) irradiation was a secondary choice which was able to withstand 10 cycles of treatment and showed small degradation by 20 cycles. However, UV can also potentially impact the material strength and fit of respirators. Finally, treatments involving liquids and vapors require caution, as steam, alcohol, and household bleach may all lead to degradation of the filtration efficiency, leaving the user vulnerable to the viral aerosols.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1101/2020.04.01.20050443

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Transmission of SARS-CoV-2 through viral aerosols. Image of SARS-CoV-2 courtesy of the CDC.
Figure 1 Transmission of SARS-CoV-2 through viral aerosols. Image of SARS-CoV-2 courtesy of the CDC.CC-BY-NC · From the PDF
Figure 2 Meltblown fabrics in N95 FFRs A. Peeling apart a representative N95 FFR reveals multiple layers of nonwoven materials. B. SEM cross section image reveals the middle meltblown layer has thinner fibers with thickness around 300 μm. C. SEM image of meltblown fibers reveals a complicated randomly-oriented network of fibers, with diameters in the range of ~110 μm. D. Schematic illustration of meltblown fibers without (left) and with (right) electret charging. In the left figure, smaller particles are able to pass through to the user, but particles are electrostatically captured in the case of an electret (right).
Figure 2 Meltblown fabrics in N95 FFRs A. Peeling apart a representative N95 FFR reveals multiple layers of nonwoven materials. B. SEM cross section image reveals the middle meltblown layer has thinner fibers with thickness around 300 μm. C. SEM image of meltblown fibers reveals a complicated randomly-oriented network of fibers, with diameters in the range of ~110 μm. D. Schematic illustration of meltblown fibers without (left) and with (right) electret charging. In the left figure, smaller particles are able to pass through to the user, but particles are electrostatically captured in the case of an electret (right).CC-BY-NC · From the PDF
Figure 3 Ten treatment cycle evolution of filtration characteristics. A. Efficiency evolution where it is clear that steam treatment results in a degradation of efficiency. B. Pressure drop evolution where it is not apparent that any structure or morphology change has occurred in the meltblown fabrics.
Figure 3 Ten treatment cycle evolution of filtration characteristics. A. Efficiency evolution where it is clear that steam treatment results in a degradation of efficiency. B. Pressure drop evolution where it is not apparent that any structure or morphology change has occurred in the meltblown fabrics.CC-BY-NC · From the PDF
Image 4
CC-BY-NC · From the PDF
Figure 5 Effect of UVGI on meltblown filtration characteristics. A. Efficiency of meltblown fabric that slightly changes after 10 cycles of UVGI. B. Pressure drop after UVGI treatments remains similar.
Figure 5 Effect of UVGI on meltblown filtration characteristics. A. Efficiency of meltblown fabric that slightly changes after 10 cycles of UVGI. B. Pressure drop after UVGI treatments remains similar.CC-BY-NC · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. Taylor P , Lusk SL , Kerr MJ , et al. American Industrial Hygiene Association Journal. 2010;: 37–41.

Cited by

See all 433

Metadata

Authors
Liao, L., Xiao, W., Zhao, M., Yu, X., Wang, H., Wang, Q., Chu, S., & Cui, Y.
Affiliations
  • 4C Air (United States) (US)
  • Stanford University (US)
  • SLAC National Accelerator Laboratory (US)
Corresponding author
Cui, Yi
Venue
ACS Nano
Publisher
openRxiv
Published
2020-04-07
Volume
14
Issue
5
Pages
6348-6356
ISSN
1936-0851 (ISSN-L)
OpenAlex
W3023977914
Cited by
433
References
32
Citations by year
2026: 11 · 2025: 13 · 2024: 39 · 2023: 67 · 2022: 75 · 2021: 132 · 2020: 96
FWCI
52.08
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • ACS Nano (publishedVersion)
  • medRxiv (acceptedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
  • Physical Sciences › Materials Science › Polymers and Plastics › Textile materials and evaluations
Keywords
N95 respirators, respirator reuse, disinfection, COVID-19 pandemic, filtration efficiency, heat treatment (food and biological processing), UV irradiation, humidity effects, personal protective equipment, virus inactivation, material degradation
MeSH terms
Disinfection, Hot Temperature, Masks, Respiratory Protective Devices, Textiles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.