Tensor Image Registration Library: Automated Non-Linear Registration of Sparsely Sampled Histological Specimens to Post-Mortem MRI of the Whole Human Brain
Open accessThe DOI matches its Crossref record; 64 of the 66 references it cites were found in a registry or an index.
Abstract
There is a need to understand the histopathological basis of MRI signal characteristics in complex biological matter. Microstructural imaging holds promise for sensitive and specific indicators of the early stages of human neurodegeneration but requires validation against traditional histological markers before it can be reliably applied in the clinical setting. Validation relies on a precise and preferably automatic method to align MRI and histological images of the same tissue, which poses unique challenges compared to more conventional MRI-to-MRI registration. A customisable open-source platform, Tensor Image Registration Library (TIRL) is presented. Based on TIRL, a fully automated pipeline was implemented to align small stained histological images with dissection photographs of corresponding tissue blocks and coronal brain slices, and further with high-resolution (0.5 mm) whole-brain post-mortem MRI data. The pipeline performed three separate deformable registrations to achieve accurate mapping between whole-brain MRI and small-slide histology coordinates. The robustness and accuracy of the individual registration steps were evaluated using both simulated data and real-life images from 6 different anatomical locations of one post-mortem human brain. The automated registration method demonstrated sub-millimetre accuracy in all steps, robustness against tissue damage, and good reproducibility between experiments. The method also outperformed manual landmark-based slice-to-volume registration, also correcting for curvatures in the slicing plane. Due to the customisability of TIRL, the pipeline can be conveniently adapted for other research needs and is therefore suitable for the large-scale comparison of routinely collected histology and MRI data. Highlights: TIRL: new framework for prototyping bespoke image registration pipelines Pipeline for automated registration of small-slide histology to whole-brain MRI Slice-to-volume registration accounting for through-plane deformations No need for serial histological sampling
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

















Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Advances in automatic co-registration tools could aid a more widespread implementation in validation studies (Huszar et al., 2019)”
From Can MRI measure myelin? Systematic review, qualitative assessment, and meta-analysis of studies validating microstructural imaging with myelin histology (2021) · cites this paper as Huszar et al., 2019
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiji: an open-source platform for biological-image analysis
Schindelin, J., Arganda-Carreras, I., Frise, E., Kaynig, V., Longair, M., Pietzsch, T., Preibisch, S., Rueden, C., Saalfeld, S., Schmid, B., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2019 · Cited by 66,890 · cited 2×
“Grey-white matter contours were defined separately for the histology images and the block photos by manually annotating approximately 200 points for each image in Fiji [64].”
MethodNeuropathological stageing of Alzheimer-related changes.
Braak, H., & Braak, E. (1991) · Acta Neuropathologica · doi:10.1007/bf00308809 · Cited by 16,123 · cited 1×
“Post-mortem studies of Parkinson’s disease [3], 74 Alzheimer’s disease [4] and amyotrophic lateral sclerosis (ALS) [5] have indicated that the 75 type of aggregates and their spatial distribution in the central nervous system are together 76 representative of the type of neurodegeneration.”
BackgroundJenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
Self-citationJenkinson, M., Beckmann, C. F., Behrens, T. E. J., Woolrich, M. W., & Smith, S. M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.015 · Cited by 11,314
Self-citationStaging of brain pathology related to sporadic Parkinson’s disease
Braak, H., Tredici, K. D., Rüb, U., de Vos, R. A. I., Jansen Steur, E. N. H., & Braak, E. (2003) · Neurobiology of Aging · doi:10.1016/s0197-4580(02)00065-9 · Cited by 10,777 · cited 1×
“Post-mortem studies of Parkinson’s disease [3], 74 Alzheimer’s disease [4] and amyotrophic lateral sclerosis (ALS) [5] have indicated that the 75 type of aggregates and their spatial distribution in the central nervous system are together 76 representative of the type of neurodegeneration.”
BackgroundA reproducible evaluation of ANTs similarity metric performance in brain image registration
Avants, B. B., Tustison, N. J., Song, G., Cook, P. A., Klein, A., & Gee, J. C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.025 · Cited by 4,796 · cited 2×
“This volume is later registered to the MRI 124 data using standard 3D registration tools such as ABA [30] or ANTs [31].”
MethodPowell, M. J. D. (1964) · The Computer Journal · doi:10.1093/comjnl/7.2.155 · Cited by 4,632 · cited 1×
“The search maximises NMI using Powell’s method [58] at 0.”
MethodPython for scientific computing
Oliphant, T. E. (2007) · Computing in Science & Engineering · doi:10.1109/mcse.2007.58 · Cited by 3,303 · cited 1×
“24 Equation (18) is eventually solved simultaneously for all pixels in the target domain for h(x) 651 using the sparse solver of SciPy [63].”
MethodNODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288 · cited 1×
“When applied to the human brain, 89 these emerging microstructural MRI methods aim to estimate tissue properties such as neurite 90 density, intracellular volume fraction [8], axon diameter [9], myelin content [10, 11], and 91”
MethodPathology of Neurodegenerative Diseases
Dugger, B. N., & Dickson, D. W. (2017) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a028035 · Cited by 1,665 · cited 1×
“Protein aggregates and neuronal 72 death are among the defining histological features of neurodegeneration [1], usually predating 73 clinical symptoms by several years [2].”
BackgroundProtein misfolding, aggregation, and conformational strains in neurodegenerative diseases
Soto, C., & Pritzkow, S. (2018) · Nature Neuroscience · doi:10.1038/s41593-018-0235-9 · Cited by 1,180
The BOBYQA algorithm for bound constrained optimization without derivatives
Powell, M. J. D. (2009) · Cited by 1,094
Numerical Methods for Image Registration
Modersitzki, J. (2003) · doi:10.1093/acprof:oso/9780198528418.001.0001 · Cited by 923 · cited 2×
“This step employs diffusion registration that was introduced by Fischer 586 and Modersitzki [52, 60, 61] and further adapted for the SSD h cost function by Heinrich et 587 al [43].”
MethodBigBrain: An Ultrahigh-Resolution 3D Human Brain Model
Amunts, K., Lepage, C., Borgeat, L., Mohlberg, H., Dickscheid, T., Rousseau, M.-É., Bludau, S., Bazin, P.-L., Lewis, L. B., Oros-Peusquens, A.-M., et al. (2013) · Science · doi:10.1126/science.1235381 · Cited by 876 · cited 1×
“139 This approach is therefore better suited to study the brains of small animals or, with substantial 140 time and workforce commitment, a single human brain [35, 36].”
BackgroundBrainSuite: An automated cortical surface identification tool
Shattuck, D. W., & Leahy, R. M. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00054-3 · Cited by 859
Axcaliber: A method for measuring axon diameter distribution from diffusion MRI
Assaf, Y., Blumenfeld‐Katzir, T., Yovel, Y., & Basser, P. J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21577 · Cited by 849 · cited 1×
“When applied to the human brain, 89 these emerging microstructural MRI methods aim to estimate tissue properties such as neurite 90 density, intracellular volume fraction [8], axon diameter [9], myelin content [10, 11], and 91”
MethodSpreading of pathology in neurodegenerative diseases: a focus on human studies
Brettschneider, J., Tredici, K. D., Lee, V. M.-Y., & Trojanowski, J. Q. (2015) · Nature Reviews Neuroscience · doi:10.1038/nrn3887 · Cited by 790 · cited 1×
“Hence the concept of neurodegeneration as a 77 prion-like spatiotemporal process has emerged [6, 7].”
BackgroundMIND: Modality independent neighbourhood descriptor for multi-modal deformable registration
Heinrich, M. P., Jenkinson, M., Bhushan, M., Matin, T., Gleeson, F. V., Brady, S. M., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.05.008 · Cited by 707 · cited 7×
“Extending the framework-building approach of Osechinskiy et 1438 al, using TIRL we successfully applied the MIND cost function [43] to register not only 1439 hemispheres, but whole brain slice photographs as well as small histological samples that could 1440 otherwise not be directly registered to MRI.”
BackgroundMethodInfluentialSelf-citationAlgorithm 247: Radical-inverse quasi-random point sequence
Halton, J. H. (1964) · Communications of the ACM · doi:10.1145/355588.365104 · Cited by 601 · cited 1×
“837 838 While the control points can be defined manually, to keep the pipeline automated, we generated 839 quasi-random two-dimensional coordinates for the control points by drawing numbers from a 840 sequence of rational fractions (Halton sequence [65]).”
Amyotrophic lateral sclerosis—a model of corticofugal axonal spread
Braak, H., Brettschneider, J., Ludolph, A. C., Lee, V. M., Trojanowski, J. Q., & Tredici, K. D. (2013) · Nature Reviews Neurology · doi:10.1038/nrneurol.2013.221 · Cited by 527
The NEWUOA software for unconstrained optimization without derivatives
Powell, M. J. D. (2006) · Nonconvex Optimization and Its Applications · doi:10.1007/0-387-30065-1_16 · Cited by 473
Compartment models of the diffusion MR signal in brain white matter: A taxonomy and comparison
Panagiotaki, E., Schneider, T., Siow, B., Hall, M. G., Lythgoe, M. F., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.081 · Cited by 422 · cited 1×
“cortical fibre orientation [12] usually by interpreting local changes of the MRI signal in the 92 framework of sophisticated biophysical models [13] of tissue structure.”
BackgroundMyelin water imaging of multiple sclerosis at 7 T: Correlations with histopathology
Laule, C., Kozlowski, P., Leung, E., Li, D. K. B., MacKay, A. L., & Moore, G. R. W. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.12.008 · Cited by 379 · cited 1×
“When applied to the human brain, 89 these emerging microstructural MRI methods aim to estimate tissue properties such as neurite 90 density, intracellular volume fraction [8], axon diameter [9], myelin content [10, 11], and 91”
MethodInsights into brain microstructure from the T2 distribution
MacKay, A., Laule, C., Vavasour, I., Bjarnason, T., Kolind, S., & Mädler, B. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.037 · Cited by 347 · cited 1×
“When applied to the human brain, 89 these emerging microstructural MRI methods aim to estimate tissue properties such as neurite 90 density, intracellular volume fraction [8], axon diameter [9], myelin content [10, 11], and 91”
MethodLarge-Scale Nonlinear Optimization
(2006) · Nonconvex Optimization and Its Applications · doi:10.1007/0-387-30065-1 · Cited by 333
A survey of methods for 3D histology reconstruction
Pichat, J., Iglesias, J. E., Yousry, T., Ourselin, S., & Modat, M. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.02.004 · Cited by 207 · cited 1×
“A comprehensive review of the methods in this category can be found in Pichat et al 119 [29].”
MethodAdvances in MRI-based computational neuroanatomy: from morphometry to in-vivo histology
Weiskopf, N., Mohammadi, S., Lutti, A., & Callaghan, M. F. (2015) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000222 · Cited by 191 · cited 1×
“Collectively these type 93 of methods have been regarded as “in-vivo histology” [14, 15] and serve as a promising non94 invasive tool for tracking tissue-level spatiotemporal changes related to human 95 neurodegeneration.”
MethodProtein aggregate spreading in neurodegenerative diseases: Problems and perspectives
Lee, S.-J., Lim, H.-S., Masliah, E., & Lee, H.-J. (2011) · Neuroscience Research · doi:10.1016/j.neures.2011.05.008 · Cited by 184 · cited 1×
“Hence the concept of neurodegeneration as a 77 prion-like spatiotemporal process has emerged [6, 7].”
BackgroundDauguet, J., Delzescaux, T., Condé, F., Mangin, J., Ayache, N., Hantraye, P., & Frouin, V. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.04.017 · Cited by 174 · cited 1×
“116 117 Methods of the first kind are well-developed with numerous examples [18-28] from as early as 118 1994.”
BackgroundMcNab, J. A., Polimeni, J. R., Wang, R., Augustinack, J. C., Fujimoto, K., Stevens, A., Janssens, T., Farivar, R., Folkerth, R. D., Vanduffel, W., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.11.065 · Cited by 158 · cited 1×
“cortical fibre orientation [12] usually by interpreting local changes of the MRI signal in the 92 framework of sophisticated biophysical models [13] of tissue structure.”
BackgroundA unified approach to fast image registration and a new curvature based registration technique
Fischer, B., & Modersitzki, J. (2004) · Linear Algebra and its Applications · doi:10.1016/j.laa.2003.10.021 · Cited by 158 · cited 3×
“This step employs diffusion registration that was introduced by Fischer 586 and Modersitzki [52, 60, 61] and further adapted for the SSD h cost function by Heinrich et 587 al [43].”
BackgroundMethodMega, M. S., Chen, S. S., Thompson, P. M., Woods, R. P., Karaca, T. J., Tiwari, A. S., Vinters, H. V., Small, G. W., & Toga, A. W. (1997) · NeuroImage · doi:10.1006/nimg.1996.0255 · Cited by 138 · cited 1×
“116 117 Methods of the first kind are well-developed with numerous examples [18-28] from as early as 118 1994.”
BackgroundFusion of autoradiographs with an MR volume using 2-D and 3-D linear transformations
Malandain, G., Bardinet, É., Nelissen, K., & Vanduffel, W. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.04.038 · Cited by 130
Yang, D., Li, H., Low, D. A., Deasy, J. O., & Naqa, I. E. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/21/017 · Cited by 111 · cited 2×
“19 the photographic intermediates requires less non-linear deformation from both ends, resulting 515 in a more symmetric registration approach with potentially less inverse-consistency error [57].”
BackgroundMethodRegistration and warping of magnetic resonance images to histological sections
Jacobs, M. A., Windham, J. P., Soltanian-Zadeh, H., Peck, D. J., & Knight, R. A. (1999) · Medical Physics · doi:10.1118/1.598671 · Cited by 102 · cited 1×
“116 117 Methods of the first kind are well-developed with numerous examples [18-28] from as early as 118 1994.”
BackgroundFast inversion of matrices arising in image processing
Fischer, B., & Jan Modersitzki, C. (1999) · Numerical Algorithms · doi:10.1023/a:1019194421221 · Cited by 102
Validation strategies for the interpretation of microstructure imaging using diffusion MRI
Dyrby, T. B., Innocenti, G. M., Bech, M., & Lundell, H. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.06.049 · Cited by 89 · cited 1×
“However, it is a matter of active debate [16] how the measured quantities 96 relate to actual histological parameters, especially in disease.”
BackgroundAccuracy of image registration between MRI and light microscopy in the ex vivo brain
Choe, A. S., Gao, Y., Li, X., Compton, K. B., Stepniewska, I., & Anderson, A. W. (2011) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.02.022 · Cited by 78 · cited 1×
“116 117 Methods of the first kind are well-developed with numerous examples [18-28] from as early as 118 1994.”
BackgroundStatistics of deformations in histology and application to improved alignment with MRI
Schormann, T., Dabringhaus, A., & Zilles, K. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.370399 · Cited by 78 · cited 1×
“116 117 Methods of the first kind are well-developed with numerous examples [18-28] from as early as 118 1994.”
BackgroundMeyer, C. R., Moffat, B. A., Kuszpit, K. K., Bland, P. H., McKeever, P. E., Johnson, T. D., Chenevert, T. L., Rehemtulla, A., & Ross, B. D. (2006) · Molecular Imaging · doi:10.2310/7290.2006.00002 · Cited by 76
BrainSuite: An Automated Cortical Surface Identification Tool
Shattuck, D. W., & Leahy, R. M. (2000) · Lecture notes in computer science · doi:10.1007/978-3-540-40899-4_6 · Cited by 75 · cited 1×
“18) 308 [51] to perform brain extraction and remove the cerebellum from the high-resolution structural 309 MRI scan before it was fed into the pipeline.”
BackgroundPallebage-Gamarallage, M., Foxley, S., Menke, R. A. L., Huszar, I. N., Jenkinson, M., Tendler, B. C., Wang, C., Jbabdi, S., Turner, M. R., Miller, K. L., et al. (2018) · BMC Neuroscience · doi:10.1186/s12868-018-0416-1 · Cited by 64 · cited 3×
“5 In order to characterise the relationship between MRI signal alterations and histopathological 99 features in motor neuron disease (MND), our group previously acquired multi-modal MRI 100 scans of whole, post-mortem human brains that were subsequently dissected into blocks for 101 histopathological staining [17].”
BackgroundMethodSelf-citationOurselin, S., Bardinet, É., Dormont, D., Malandain, G., Roche, A., Ayache, N., Tandé, D., Parain, K., & Yelnik, J. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45468-3_89 · Cited by 58
Improving diffusion-weighted imaging of post-mortem human brains: SSFP at 7T
Foxley, S., Jbabdi, S., Clare, S., Lam, W. W., Ansorge, O., Douaud, G., & Miller, K. L. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.08.014 · Cited by 57 · cited 1×
“25 235 mm isotropic resolution (also referred to as 3D-TRUFI) [17, 48].”
BackgroundSelf-citationCo-registration of Histological, Optical and MR Data of the Human Brain
Bardinet, É., Sebastien Ourselin, A., Dormont, D., Malandain, G., Tandé, D., Parain, K., Ayache, N., & Yelnik, J. (2002) · Lecture notes in computer science · doi:10.1007/3-540-45786-0_68 · Cited by 52 · cited 1×
“116 117 Methods of the first kind are well-developed with numerous examples [18-28] from as early as 118 1994.”
BackgroundHigh-Resolution Anatomy from in Situ Human Brain
Toga, A. W., Ambach, K. L., & Schluender, S. J. (1994) · NeuroImage · doi:10.1006/nimg.1994.1018 · Cited by 49
Integration of ultra-high field MRI and histology for connectome based research of brain disorders
Yang, S., Yang, Z., Fischer, K., Zhong, K., Stadler, J., Godenschweger, F., Steiner, J., Heinze, H., Bernstein, H., Bogerts, B., et al. (2013) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2013.00031 · Cited by 41 · cited 1×
“116 117 Methods of the first kind are well-developed with numerous examples [18-28] from as early as 118 1994.”
BackgroundSlice-to-Volume Nonrigid Registration of Histological Sections to MR Images of the Human Brain
Osechinskiy, S., & Kruggel, F. (2011) · Anatomy Research International · doi:10.1155/2011/287860 · Cited by 39
Diffusion MRI: From Quantitative Measurement to In vivo Neuroanatomy: Second Edition
Johansen‐Berg, H., & Behrens, T. E. J. (2013) · Cited by 35
Automatic registration of postmortem brain slices to MRI reference volume
Kim, T. S., Singh, M., Sungkarat, W., Zarow, C., & Chui, H. C. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873023 · Cited by 34
Possum—A Framework for Three-Dimensional Reconstruction of Brain Images from Serial Sections
Majka, P., & Wojcik, D. K. (2015) · Neuroinformatics · doi:10.1007/s12021-015-9286-1 · Cited by 34 · cited 2×
“Recently, Majka et al [46] released Possum, an open-source framework for 183 reconstructing volumetric histology data, which is a great step toward standardising this aspect 184 of stack-based MRI-histology registration.”
BackgroundIglesias, J. E., Modat, M., Peter, L., Stevens, A. A., Annunziata, R., Vercauteren, T. K., Lein, E. S., Fischl, B. R., & Ourselin, S. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.09.002 · Cited by 33 · cited 1×
“et al [32] recently demonstrated accurate (0.”
Multimodal Whole Brain Registration: MRI and High Resolution Histology
Alegro, M., Amaro, E., Loring, B., Heinsen, H., Alho, E. J. L., Zöllei, L., Ushizima, D. M., & Grinberg, L. T. (2016) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw.2016.85 · Cited by 32 · cited 3×
“A recent preprint by Alegro et al [36, 47] reported 185 an automated pipeline for serial histological sections.”
BackgroundMethodMatching ex vivo MRI With Iron Histology: Pearls and Pitfalls
De Barros, A., Arribarat, G., Combis, J., Chaynes, P., & Péran, P. (2019) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2019.00068 · Cited by 31 · cited 1×
“As a 180 consequence, new experimenters are repeatedly required to invest time and effort into 181 extensive hardware and/or software development [45], which negatively impacts large-scale 182 validation studies.”
BackgroundCo‐registration of in vivo human MRI brain images to postmortem histological microscopic images
Singh, M., Rajagopalan, A., Kim, T., Hwang, D., Chui, H. C., Zhang, X., Lee, A., & Zarow, C. (2008) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.20168 · Cited by 18 · cited 3×
“The method was later used by Singh et al [38] to register histological images of vascular lesions to in-vivo MRI data using photographic intermediates, reporting an overall registration accuracy of 3-8 mm. Meyer et al [39] reported a semi-automated registration method to align a histological section of murine glioma t…”
MethodGlobal optimisation for robust affine registration
Jenkinson, M., & Smith, S. M. (2000) · NeuroImage · doi:10.1016/s1053-8119(00)91410-1 · Cited by 17
Self-citationDeformable image registration between pathological images and MR image via an optical macro image
Ohnishi, T., Nakamura, Y., Tanaka, T., Tanaka, T., Hashimoto, N., Haneishi, H., Batchelor, T. T., Gerstner, E. R., Taylor, J. W., Snuderl, M., et al. (2016) · Pathology - Research and Practice · doi:10.1016/j.prp.2016.07.018 · Cited by 16 · cited 2×
“The registration of small histological sections (as opposed to whole-hemisphere images) was studied by Ohnishi et al [44].”
MethodBoothroyd, J. (1964) · Communications of the ACM · doi:10.1145/355588.355589 · Cited by 16
Part-to-Whole Registration of Histology and MRI Using Shape Elements
Pichat, J., Iglesias, J. E., Nousias, S., Yousry, T. A., Ourselin, S., & Modat, M. (2017) · IEEE International Conference on Computer Vision Workshops · doi:10.1109/iccvw.2017.21 · Cited by 12 · cited 3×
“Complementary to this work, Pichat et al [33] proposed a method for direct histology-to-MRI registration between small histological samples (as opposed to whole-hemisphere images) and corresponding MRI slices via automated affine-invariant shape matching, but only reported preliminary results that required manual MRI…”
MethodInfluentialRevisiting Horn and Schunck: Interpretation as Gauss-Newton Optimisation
Zikic, D., Kamen, A., & Navab, N. (2010) · British Machine Vision Conference (BMVC) · doi:10.5244/c.24.113 · Cited by 11
Anderson, A. W., Choe, A. S., Stepniewska, I., & Colvin, D. C. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259554 · Cited by 7 · cited 1×
“116 117 Methods of the first kind are well-developed with numerous examples [18-28] from as early as 118 1994.”
BackgroundOsechinskiy, S., & Kruggel, F. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091208 · Cited by 7 · cited 1×
“As a further refinement to the technique, they devised a novel similarity metric 168 based on the correspondence of grey-white matter boundaries [42].”
MethodAutomating Whole Brain Histology to MRI Registration: Implementation of a Computational PipelinePreprint
Alegro, M., Alho, E. J. L., Martin, M. D. G. M., Grinberg, L. T., Heinsen, H., Lopes, R. D. D., Amaro-Jr, E., & Zöllei, L. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1905.09339 · Cited by 5 · cited 2×
“A recent preprint by Alegro et al [36, 47] reported 185 an automated pipeline for serial histological sections.”
MethodIdentifying global anatomical differences: Deformation-based morphometry
(1998) · doi:10.1002/(sici)1097-0193(1998)6:5/6
Research works printed but not linked: 1
- Rohde, G.K., A. Aldroubi, and B.M. Dawant, Adaptive-bases algorithm for nonrigid image registration. Medical Imaging 2002. Vol. 4684. 2002: SPIE.
Cited by
Lazari, A., & Lipp, I. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.117744 · Cited by 197
An open resource combining multi-contrast MRI and microscopy in the macaque brain
Howard, A. F. D., Huszár, I. N., Smart, A., Cottaar, M., Daubney, G., Hanayik, T., Khrapitchev, A. A., Mars, R. B., Mollink, J., Scott, C., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-39916-1 · Cited by 77
Self-citationWang, C., Foxley, S., Ansorge, O., Bangerter-Christensen, S., Chiew, M., Leonte, A., Menke, R., Mollink, J., Pallebage‐Gamarallage, M. M., Turner, M. R., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117216 · Cited by 61
Self-citationThe Digital Brain Bank, an open access platform for post-mortem imaging datasets
Tendler, B. C., Hanayik, T., Ansorge, O., Bangerter-Christensen, S., Berns, G. S., Bertelsen, M. F., Bryant, K., Foxley, S., van den Heuvel, M. P., Howard, A. F. D., et al. (2022) · eLife · doi:10.7554/elife.73153 · Cited by 63
“To address this, our group has developed TIRL, a novel MR-microscopy coregistration toolbox ( Huszar et al., 2019 ).”
BackgroundMethodInfluentialSelf-citationVisualising spatial heterogeneity in glioblastoma using imaging habitats
Waqar, M., van Houdt, P. J., Hessen, E. D., Li, K., Zhu, X., Jackson, A., Iqbal, M., O’Connor, J. P. B., Djoukhadar, I., van der Heide, U. A., et al. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.1037896 · Cited by 48
Metadata
- Authors
- Huszar, I. N., Pallebage-Gamarallage, M., Foxley, S., Tendler, B. C., Leonte, A., Hiemstra, M., Mollink, J., Smart, A., Bangerter-Christensen, S., Brooks, H., Turner, M. R., Ansorge, O., Miller, K. L., & Jenkinson, M.
- Affiliations
- University of Oxford (GB)
- University of Groningen (NL)
- Radboud University Nijmegen (NL)
- Brigham Young University (US)
- ORCID
- Venue
- bioRxiv (Cold Spring Harbor Laboratory)
- Publisher
- openRxiv
- Published
- 2019-11-26
- OpenAlex
- W2991278233
- Cited by
- 11
- References
- 66
- Citations by year
- 2025: 1 · 2023: 2 · 2022: 3 · 2021: 3 · 2020: 2
- Type
- posted content
- Language
- en
- Open access
- green
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- bioRxiv (Cold Spring Harbor Laboratory) (acceptedVersion, cc-by-nc-nd)
- Funders
- Wellcome Trust (203139/Z/16/Z, 202788/Z/16/Z, 203139)
- Alzheimer's Society
- National Institute for Health and Care Research (203139/Z/16/Z)
- Max-Planck-Gesellschaft
- Medical Research Council (MR/K02213X/1, 203139/Z/16/Z, EP/L016052/1)
- Engineering and Physical Sciences Research Council (EP/L016052/1, EP/L016052, 203139/Z/16/Z)
- NIHR Oxford Biomedical Research Centre (203139/Z/16/Z)
- Clarendon Fund
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Keywords
- image registration, nonlinear registration, whole-brain MRI, histological slides, deformable image registration, slice-to-volume registration, neurodegeneration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.