The DOI matches its Crossref record; 60 of the 67 references it cites were found in a registry or an index; 43 of the 64 sources its claims cite were checked for support.
Long-distance chronometric leveling with a portable optical clock
Open accessAbstract
We have measured the geopotential difference between two locations separated by 457 km by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The 87Sr clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured geopotential difference of 3918.1(2.6) m^2 s^-2 agrees with an independent geodetic determination of 3915.88(0.30) m^2 s^-2. The uncertainty of the chronometric geopotential difference is equivalent to an uncertainty of 27 cm in height.
Overview
CoChat Summary
TL;DR
The paper demonstrates long-distance chronometric leveling over 457 km by comparing two \(^{87}\)Sr optical lattice clocks via a 940-km interferometric fiber link. The chronometrically measured geopotential difference agrees with an independent GNSS/geoid determination.
Key findings
- The chronometric geopotential difference between PTB and MPQ was \(3918.1(2.6)\ \mathrm{m^2\,s^{-2}}\), agreeing with the geodetic value \(3915.88(0.30)\ \mathrm{m^2\,s^{-2}}\); the chronometric uncertainty corresponds to 27 cm in height.
- A local fractional clock offset of \(\Delta\nu_{\mathrm{loc}}/\nu_0 = 50(32)\times 10^{-18}\) was observed between the two \(^{87}\)Sr clocks, and the remote offset was \(\Delta\nu_{\mathrm{rem}}/\nu_0 = 43645(36)\times 10^{-18}\).
- The measurement achieved a height resolution below 30 cm and fractional frequency resolution of \(3\times 10^{-17}\) within one hour, and 6 cm within one day.
- Remote comparison instability was \(1.7\times 10^{-15}/\sqrt{\tau/\mathrm{s}}\), slightly higher than the local comparison instability of \(1.0\times 10^{-15}/\sqrt{\tau/\mathrm{s}}\).
Methods
- Two \(^{87}\)Sr optical lattice clocks were used: the transportable Sr2 was compared side-by-side with the stationary Sr1 at PTB before, during, and after transport to MPQ; the sites are 457 km apart with a 400 m height difference and connected by a 940-km interferometric fiber link.
- Beat notes were counted with synchronized, dead-time-free counters in phase-averaging mode at 1 s averaging; daily frequency offsets were averaged with weights \(1/u(\Delta\nu_{\mathrm{day}})^2\), accounting for correlations of systematic corrections.
- The geodetic comparison used the GNSS/geoid approach with the EGG2015 model, plus geometric leveling for small height differences between benchmarks and clocks.
Limitations
- The paper states that the significant local frequency offset between clocks operating on the same transition of the same isotope is unexpected and its reason remains unclear; the analysis assumes the offset during the remote comparison had the same value as observed locally.
- Time-variable gravity effects, mainly solid Earth and ocean tides, are stated to be below \(0.5\ \mathrm{m^2\,s^{-2}}\) maximum amplitude for the PTB–MPQ potential difference and are neglected because they largely average out over longer recording times.
- The instability is stated to be limited by the transportable clock Sr2, mainly due to Dick noise of the transportable clock laser; the paper also notes that future work aims to reduce Sr2’s systematic uncertainty to the \(10^{-18}\) level or below.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
19 Valid · 11 Not valid · 6 Not checked · 42 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The chronometrically measured geopotential difference of 3918 . 1(2 . 6) m 2 s -2 agrees with an independent geodetic determination of 3915 . 88(0 . 30) m 2 s -2 .”
- Also stated in: § Long-distance chronometric leveling with a portable optical clock · p. 1 · plain
“To verify our chronometric leveling result, we compare it with the result of the GNSS/geoid approach and find good agreement.”
- Also stated in: § Long-distance chronometric leveling with a portable optical clock · p. 4 · plain
“Its measured value is 3918 . 1(2 . 6) m 2 s -2 , which agrees with the independent, geodetic determination of 3915 . 88(0 . 30) m 2 s -2 (Fig. 3).”
What the sources say
- Partly supportedcites [23] sourceExperimental — accuracy not yet measured
Section 5 (page unavailable) reports that a comparison of optical clocks at PTB and OBSPARIS agreed with geodetic results to about 5 × 10⁻¹⁷. It does not give the cited geopotential differences of 3918.1(2.6) and 3915.88(0.30) m² s⁻² or identify the comparison result specifically as a GNSS/geoid determination. (LLM, conf=0.83)
plainstates an associationSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § Long-distance chronometric leveling with a portable optical clock · p. 1 · plain
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Furthermore, the frequency of two atomic clocks can be compared via an interferometric fiber link (IFL), which supports sub-10 -19 accuracy over hundreds of kilometers [5-10].”
What the sources say
- Not checked — no full text of the sourcecites [5] source
- Partly supportedcites [6] sourceExperimental — accuracy not yet measured
The Results (Optical link between the clocks; page unavailable) describe comparing two clocks through 1,415 km of coherent fibre links. But Methods (Instability and uncertainty contribution by the link; page unavailable) gives an overall link systematic uncertainty of <2.5 × 10−19, not sub-10−19; the Abstract reports clock-comparison uncertainty of 5 × 10−17. (LLM, conf=0.90)
- Supportedcites [7] source
The Introduction describes noise-corrected optical fiber links as a technique for comparing distant optical clocks, reporting transfer over more than 1000 km with uncertainties around 10^-20 or lower. Section 3.2 describes the interferometric frequency-comparison method. Together, these support the claimed capability over hundreds of kilometers; the claim does not require every link tested in this paper to meet that accuracy. (LLM, conf=0.88)
- Partly supportedcites [8] sourceExperimental — accuracy not yet measured
The Introduction (p. 2) says optical-fiber transmission enables comparisons of distant atomic clocks, and the Introduction (p. 3) describes a phase-stabilized link reaching telescopes 600 km apart. But this paper's experiment distributed one common clock signal, rather than comparing two independent clocks, and our copy does not establish sub-10^-19 accuracy for such a comparison. (LLM, conf=0.87)
- Not checked — no full text of the sourcecites [9] source
- Supportedcites [10] source
The Results section (‘Direct evaluation of the total link noise with ultrastable lasers’; page unavailable) reports fractional-frequency uncertainties below 10⁻¹⁹ over fibre links longer than 700 km. The paper also describes fibre-linked optical-clock comparisons in its References (page unavailable). Its own 2220 km experiment compared lasers, so the sub-10⁻¹⁹ figure is reported link performance, not the accuracy measured in that experiment. (LLM, conf=0.86)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The chronometrically measured geopotential difference of 3918 . 1(2 . 6) m 2 s -2 agrees with an independent geodetic determination of 3915 . 88(0 . 30) m 2 s -2 .”
- Also stated in: § Long-distance chronometric leveling with a portable optical clock · p. 4 · plain
“Its measured value is 3918 . 1(2 . 6) m 2 s -2 , which agrees with the independent, geodetic determination of 3915 . 88(0 . 30) m 2 s -2 (Fig. 3).”
What the sources say
- Partly supportedcites [23] sourceExperimental — accuracy not yet measured
Section 4.4 reports independently derived geodetic geopotential values, and the station values reproduced in Section 5 permit a difference near 3915.88 m² s⁻². Our copy does not state the claimed value or its 0.30 m² s⁻² uncertainty, so it does not substantiate the precise determination attributed to it (page numbers unavailable). (LLM, conf=0.78)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § Long-distance chronometric leveling with a portable optical clock · p. 4 · plain
Every source the paper cites for this claim was checked and supports it.
In the paper
“Furthermore, it should be noted that existing geometric leveling data from the German height network (DHHN92) have also been used to derive the potential difference between the PTB and MPQ clock positions, resulting in a deviation to the recommended value from the GNSS/geoid approach of only 0 . 3 m 2 s -2 [23].”
What the sources say
- Supportedcites [23] source
Section 5 (page unavailable) reports that the PTB–MPQ potential difference from geometric levelling differs from the GNSS/geoid result by 0.032 m in equivalent height, approximately 0.3 m² s⁻². The paper identifies DHHN92 as the German national levelling network; the claim’s figure is a rounded expression of the reported difference. (LLM, conf=0.90)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The main contribution is Dick noise [61] of the transportable clock laser [56].”
What the sources say
- Not matchedcites [61]
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Partly supportedcites [56] sourceExperimental — accuracy not yet measured
In the introduction (page not specified), Katori says optical clocks commonly suffer Dick-effect instability and that optical-local-oscillator instability limits their stability. The paper discusses developing transportable clocks, but does not identify Dick noise from a particular transportable clock laser as the main contribution to instability. (LLM, conf=0.84)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
37 more claims · 6 with their cited sources checked
Create a free account to see all 78 claims and every source verdict.
- It may state two separate claims as one. 26
- Probably not a substantial claim. 14
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ A. Ambient BBR shift · p. 8
“We estimate the representative temperature by ( T max -T min ) / 2 and its uncertainty by ( T max -T min ) / √ 12.”
§ A. Ambient BBR shift · p. 8
“Here, it is assumed that the representative temperature that leads to the BBR shift experienced by the atoms lies with equal probability between the boundaries T max and T min [39].”
Citations
Cites
Chou, C. W., Hume, D. B., Rosenband, T., & Wineland, D. J. (2010) · Science · doi:10.1126/science.1192720 · Cited by 828 · cited 1×
“This leads to the concept of physical heights that are directly related to the geopotential (a physical quantity), in contrast to the purely geometrically defined el-lipsoidal heights (distance of a point from a given reference ellipsoid) from Global Navigation Satellite Systems (GNSS) measurements…”
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780 · cited 1×
“(1) and (2) in the main paper: where we have omitted the labels rem/loc for clarity.”
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627 · cited 1×
“This gravitational redshift can also be understood as the change of potential energy of the photons employed to compare the clocks.”
1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584 · cited 1×
“After the transportable clock was moved to MPQ, within one week ultracold 87 Sr atoms were trapped in the optical lattice and the clock transition was found.”
A 920-Kilometer Optical Fiber Link for Frequency Metrology at the 19th Decimal Place
Predehl, K., Grosche, G., Raupach, S. M. F., Droste, S., Terra, O., Alnis, J., Legero, T., Hänsch, T. W., Udem, T., Holzwarth, R., et al. (2012) · Science · doi:10.1126/science.1218442 · Cited by 543 · cited 1×
“Hence, the effect can now be utilized in geodesy to revolutionize geopotential and physical height determination capabilities.”
Self-citationTest of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507 · cited 1×
“For long-distance geodetic measurements, however, independent clocks have to be used.”
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Self-citationA clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460 · cited 2×
“This leads to the concept of physical heights that are directly related to the geopotential (a physical quantity), in contrast to the purely geometrically defined el-lipsoidal heights (distance of a point from a given reference ellipsoid) from Global Navigation Satellite Systems (GNSS) measurements…”
Self-citationResolving the gravitational redshift across a millimetre-scale atomic sample
Bothwell, T., Kennedy, C. J., Aeppli, A., Kedar, D., Robinson, J. M., Oelker, E., Staron, A., & Ye, J. (2022) · Nature · doi:10.1038/s41586-021-04349-7 · Cited by 449 · cited 2×
“This gravitational redshift can also be understood as the change of potential energy of the photons employed to compare the clocks.”
Frequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
JILA SrI optical lattice clock with uncertainty of 2.0 × 10 − 18
Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J. (2019) · Metrologia · doi:10.1088/1681-7575/ab4089 · Cited by 324 · cited 1×
“To reduce line pulling effects, we remove population from other Zeeman levels by resonant laser radiation on the 461 nm singlet transition after we have excited the population in m F = ± 9 / 2 from the ground state to the upper clock state by a short π -pulse in a large bias field.”
8 × 10^−17 fractional laser frequency instability with a long room-temperature cavity
Häfner, S., Falke, S., Grebing, C., Vogt, S., Legero, T., Merimaa, M., Lisdat, C., & Sterr, U. (2015) · Optics Letters · doi:10.1364/ol.40.002112 · Cited by 286 · cited 1×
“Thus, we regard ∆ ν loc as a calibration for the clock’s frequency ratio, as it is required if two clocks of different types with an unknown frequency ratio are used for chronometric leveling.”
Self-citationMehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263 · cited 2×
“In current state-of-the-art geodesy, however, the in-homogeneity of the gravity field must be taken into account.”
Self-citationGeopotential measurements with synchronously linked optical lattice clocks
Takano, T., Takamoto, M., Ushijima, I., Ohmae, N., Akatsuka, T., Yamaguchi, A., Kuroishi, Y., Munekane, H., Miyahara, B., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.159 · Cited by 245 · cited 2×
“This leads to the concept of physical heights that are directly related to the geopotential (a physical quantity), in contrast to the purely geometrically defined el-lipsoidal heights (distance of a point from a given reference ellipsoid) from Global Navigation Satellite Systems (GNSS) measurements…”
Transportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238 · cited 7×
“The gravitational redshift difference is given by ∆ ν = ( ν 0 g PTB /c 2 ) ∆ h day , with the clock transition frequency ν 0 ≈ 429 .”
InfluentialSelf-citationNuclear spin effects in optical lattice clocks
Boyd, M. M., Zelevinsky, T., Ludlow, A. D., Blatt, S., Zanon-Willette, T., Foreman, S. M., & Ye, J. (2007) · Physical Review A · doi:10.1103/physreva.76.022510 · Cited by 186 · cited 1×
“This procedure leads to a strong reduction of the possible effect and thus a negligible uncertainty contribution (see also Sr1 in Tab.”
A strontium lattice clock with 3 × 10−17inaccuracy and its frequency
Falke, S., Lemke, N., Grebing, C., Lipphardt, B., Weyers, S., Gerginov, V., Huntemann, N., Hagemann, C., Al-Masoudi, A., Häfner, S., et al. (2014) · New Journal of Physics · doi:10.1088/1367-2630/16/7/073023 · Cited by 182 · cited 1×
“In a local measurement, two transportable lattice clocks were used to measure the gravitational red-shift induced by 450 m of height difference at the Tokyo Skytree and achieved a height resolution of about 4 cm FIG.”
Self-citationHigh Accuracy Correction of Blackbody Radiation Shift in an Optical Lattice Clock
Middelmann, T., Falke, S., Lisdat, C., & Sterr, U. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.263004 · Cited by 177 · cited 2×
“In combination with a deep lattice of 50 E r and more, tunneling is strongly suppressed as are tunneling-related frequency shifts [S16].”
Self-citationBjerhammar, A. (1985) · Bulletin Géodésique · doi:10.1007/bf02520327 · Cited by 165
Origlia, S., Pramod, M. S., Schiller, S., Singh, Y., Bongs, K., Schwarz, R., Al-Masoudi, A., Dörscher, S., Herbers, S., Häfner, S., et al. (2018) · Physical Review A · doi:10.1103/physreva.98.053443 · Cited by 142 · cited 1×
“Previously, extremely small redshifts have been resolved with optical clocks [12, 13] by differential observations in a single apparatus.”
Self-citationThe87Sr optical frequency standard at PTB
Falke, S., Schnatz, H., Winfred, J. S. R. V., Middelmann, T., Vogt, S., Weyers, S., Lipphardt, B., Grosche, G., Riehle, F., Sterr, U., et al. (2011) · Metrologia · doi:10.1088/0026-1394/48/5/022 · Cited by 129 · cited 1×
“9(4) × 10 − 17 .”
Self-citationSchioppo, M., Kronjäger, J., Silva, A., Ilieva, R., Paterson, J. W., Baynham, C. F. A., Bowden, W., Hill, I. R., Hobson, R., Vianello, A., et al. (2022) · Nature Communications · doi:10.1038/s41467-021-27884-3 · Cited by 118 · cited 1×
“Hence, the effect can now be utilized in geodesy to revolutionize geopotential and physical height determination capabilities.”
Self-citationOperational Magic Intensity for Sr Optical Lattice Clocks
Ushijima, I., Takamoto, M., & Katori, H. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.263202 · Cited by 116 · cited 3×
“The procedure remains unchanged from the one described in Ref.”
Optical lattice clock with atoms confined in a shallow trap
Lemonde, P., & Wolf, P. (2005) · Physical Review A · doi:10.1103/physreva.72.033409 · Cited by 114 · cited 2×
“Since the Sr1 laser is tied to the strontium transition frequency during the valid times of the comparison, drifts are essentially removed from the Sr2 interrogation laser.”
Raupach, S. M. F., Koczwara, A., & Grosche, G. (2015) · Physical Review A · doi:10.1103/physreva.92.021801 · Cited by 101
Self-citationAccuracy evaluation of an optical lattice clock with bosonic atoms
Baillard, X., Fouché, M., Le Targat, R., Westergaard, P. G., Lecallier, A., Le Coq, Y., Rovera, G. D., Bize, S., & Lemonde, P. (2007) · Optics Letters · doi:10.1364/ol.32.001812 · Cited by 100 · cited 1×
“This procedure leads to a strong reduction of the possible effect and thus a negligible uncertainty contribution (see also Sr1 in Tab.”
Common-clock very long baseline interferometry using a coherent optical fiber link
Clivati, C., Aiello, R., Bianco, G., Bortolotti, C., De Natale, P., Di Sarno, V., Maddaloni, P., Maccaferri, G., Mura, A., Negusini, M., et al. (2020) · Optica · doi:10.1364/optica.393356 · Cited by 99
Denker, H., Timmen, L., Voigt, C., Weyers, S., Peik, E., Margolis, H. S., Delva, P., Wolf, P., & Petit, G. (2018) · Journal of Geodesy · doi:10.1007/s00190-017-1075-1 · Cited by 91 · cited 5×
“0 × 10 − 15 / τ/ s, Fig.”
InfluentialNoise and instability of an optical lattice clock
Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2015) · Physical Review A · doi:10.1103/physreva.92.063814 · Cited by 84 · cited 1×
“We estimate the representative temperature by ( T max − T min ) / 2 and its uncertainty by ( T max − T min ) / √ 12.”
Self-citationStrategy for the realisation of the International Height Reference System (IHRS)
Sánchez, L., Ågren, J., Huang, J., Wang, Y. M., Mäkinen, J., Pail, R., Barzaghi, R., Vergos, G. S., Ahlgren, K., & Liu, Q. (2021) · Journal of Geodesy · doi:10.1007/s00190-021-01481-0 · Cited by 84 · cited 1×
“The most widely known geodetic technique to derive physical heights is geometric leveling (also known as spirit leveling) in combination with local gravity measurements.”
Liquid-Nitrogen-Cooled Ca + Optical Clock with Systematic Uncertainty of 3×10−18
Huang, Y., Zhang, B., Zeng, M., Hao, Y., Ma, Z., Zhang, H., Guan, H., Chen, Z., Wang, M., & Gao, K. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.034041 · Cited by 82
Ohmae, N., Takamoto, M., Takahashi, Y., Kokubun, M., Araki, K., Hinton, A., Ushijima, I., Muramatsu, T., Furumiya, T., Sakai, Y., et al. (2021) · Advanced Quantum Technologies · doi:10.1002/qute.202100015 · Cited by 79
Benkler, E., Lisdat, C., & Sterr, U. (2015) · Metrologia · doi:10.1088/0026-1394/52/4/565 · Cited by 72 · cited 1×
“Other transportable clocks are in development but have not yet been used in off-campus measurement campaigns [18–23].”
Self-citationLong term measurement of theSr87clock frequency at the limit of primary Cs clocks
Schwarz, R., Dörscher, S., Al-Masoudi, A., Benkler, E., Legero, T., Sterr, U., Weyers, S., Rahm, J., Lipphardt, B., & Lisdat, C. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.033242 · Cited by 64
Self-citationLattice-induced photon scattering in an optical lattice clock
Dörscher, S., Schwarz, R., Al-Masoudi, A., Falke, S., Sterr, U., & Lisdat, C. (2018) · Physical Review A · doi:10.1103/physreva.97.063419 · Cited by 60
Self-citationAn accurate and robust metrological network for coherent optical frequency dissemination
Cantin, E., Tønnes, M., Le Targat, R., Amy-Klein, A., Lopez, O., & Pottie, P.-E. (2021) · New Journal of Physics · doi:10.1088/1367-2630/abe79e · Cited by 59
Optical frequency distribution using laser repeater stations with planar lightwave circuits
Akatsuka, T., Goh, T., Imai, H., Oguri, K., Ishizawa, A., Ushijima, I., Ohmae, N., Takamoto, M., Katori, H., Hashimoto, T., et al. (2020) · Optics Express · doi:10.1364/oe.383526 · Cited by 55
Geopotential measurement with a robust, transportable Ca+ optical clock
Huang, Y., Zhang, H., Zhang, B., Hao, Y., Guan, H., Zeng, M., Chen, Q., Lin, Y., Wang, Y., Cao, S., et al. (2020) · Physical Review A · doi:10.1103/physreva.102.050802 · Cited by 52 · cited 1×
“Previously, extremely small redshifts have been resolved with optical clocks [12, 13] by differential observations in a single apparatus.”
End-to-end topology for fiber comb based optical frequency transfer at the 10 −21 level
Benkler, E., Lipphardt, B., Puppe, T., Wilk, R., Rohde, F., & Sterr, U. (2019) · Optics Express · doi:10.1364/oe.27.036886 · Cited by 51 · cited 1×
“The lattice light shift is remeasured in each campaign and thus is only correlated within a campaign.”
Self-citationVoigt, C., Denker, H., & Timmen, L. (2016) · Metrologia · doi:10.1088/0026-1394/53/6/1365 · Cited by 50 · cited 1×
“4, we achieve a height resolution below 30 cm and a corresponding fractional frequency resolution of 3 × 10 − 17 within one hour of measurement, and 6 cm within one day.”
A lab-based test of the gravitational redshift with a miniature clock network
Zheng, X., Dolde, J., Cambria, M. C., Lim, H. M., & Kolkowitz, S. (2023) · Nature Communications · doi:10.1038/s41467-023-40629-8 · Cited by 47 · cited 1×
“Previously, extremely small redshifts have been resolved with optical clocks [12, 13] by differential observations in a single apparatus.”
Transportable clock laser system with an instability of 1.6 × 10 −16
Herbers, S., Häfner, S., Dörscher, S., Lücke, T., Sterr, U., & Lisdat, C. (2022) · Optics Letters · doi:10.1364/ol.470984 · Cited by 47 · cited 1×
“30 m 2 s − 2 for the geopoten-tial difference is based on the uncertainties (in height) of GNSS positioning (1.0 cm) and the EGG2015 model (1.9 cm), with negligible correlations.”
InfluentialSelf-citationReal-time phase tracking for wide-band optical frequency measurements at the 20th decimal place
Giunta, M., Hänsel, W., Fischer, M., Lezius, M., Udem, T., & Holzwarth, R. (2020) · Nature Photonics · doi:10.1038/s41566-019-0520-5 · Cited by 41 · cited 1×
“The lattice light shift is remeasured in each campaign and thus is only correlated within a campaign.”
Self-citationA perspective on the future of transportable optical lattice clocks
Takamoto, M., Tanaka, Y., & Katori, H. (2022) · Applied Physics Letters · doi:10.1063/5.0087894 · Cited by 40 · cited 1×
“4, we achieve a height resolution below 30 cm and a corresponding fractional frequency resolution of 3 × 10 − 17 within one hour of measurement, and 6 cm within one day.”
Opticlock: Transportable and easy-to-operate optical single-ion clock
Stuhler, J., Abdel Hafiz, M., Arar, B., Bawamia, A., Bergner, K., Biethahn, M., Brakhane, S., Didier, A., Fortágh, J., Halder, M., et al. (2021) · Measurement: Sensors · doi:10.1016/j.measen.2021.100264 · Cited by 38
Self-citationDirect comparisons of European primary and secondary frequency standards via satellite techniques
Riedel, F., Al-Masoudi, A., Benkler, E., Dörscher, S., Gerginov, V, Grebing, C., Häfner, S., Huntemann, N., Lipphardt, B., Lisdat, C., et al. (2020) · Metrologia · doi:10.1088/1681-7575/ab6745 · Cited by 38
Self-citationMuniz, J. A., Young, D. J., Cline, J. R. K., & Thompson, J. K. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.023152 · Cited by 38 · cited 1×
“This procedure leads to a strong reduction of the possible effect and thus a negligible uncertainty contribution (see also Sr1 in Tab.”
Polarizabilities of theSr87clock transition
Shi, C., Robyr, J.-L., Eismann, U., Zawada, M., Lorini, L., Le Targat, R., & Lodewyck, J. (2015) · Physical Review A · doi:10.1103/physreva.92.012516 · Cited by 37 · cited 1×
“For the determination of the residual lattice light shift, we interleave during normal clock operation measurements [S7] with lattice depths of typically 75 E r and 170 E r and measure the differential frequency shift.”
Transportable interrogation laser system with an instability of mod σy = 3 × 10−16
Häfner, S., Herbers, S., Vogt, S., Lisdat, C., & Sterr, U. (2020) · Optics Express · doi:10.1364/oe.390105 · Cited by 37 · cited 2×
“…was first used for the computation of the potential difference between the benchmarks near the clock experiments, while the remaining, small height differences between the benchmarks and the clocks were measured by geometric leveling and then converted to a potential difference using g MPQ ≈ 9 .”
Self-citationCombined result and associated uncertainty from interlaboratory evaluations based on the ISO Guide
Kacker, R., Datla, R., & Parr, A. (2002) · Metrologia · doi:10.1088/0026-1394/39/3/5 · Cited by 36 · cited 1×
“813 m s − 2 , and the height difference between the two clocks ∆ h day = h Sr2 , day − h Sr1 . h Sr2 , day is constant within each local campaign at PTB, but differs slightly between both campaigns.”
Blackbody radiation shift in strontium lattice clocks revisited
Lisdat, C., Dörscher, S., Nosske, I., & Sterr, U. (2021) · Physical Review Research · doi:10.1103/physrevresearch.3.l042036 · Cited by 36
Self-citationLongitudinal Ramsey spectroscopy of atoms for continuous operation of optical clocks
Katori, H. (2021) · Applied Physics Express · doi:10.35848/1882-0786/ac0e16 · Cited by 31 · cited 10×
“Consequently, it offers an attractive way to resolve existing discrepancies (at the centimeter to decimeter level) between the established geodetic methods, overcome their limitations, improve continental and global height reference frames, connect island and mainland height systems, connect tide gauges for sea level…”
InfluentialExploring potential applications of optical lattice clocks in a plate subduction zone
Tanaka, Y., & Katori, H. (2021) · Journal of Geodesy · doi:10.1007/s00190-021-01548-y · Cited by 31
Transportable optical atomic clocks for use in out-of-the-lab environments
Gellesch, M., Jones, J., Barron, R., Singh, A., Sun, Q., Bongs, K., & Singh, Y. (2020) · Advanced Optical Technologies · doi:10.1515/aot-2020-0023 · Cited by 26
Toward a Transportable Ca+ Optical Clock with a Systematic Uncertainty of 4.8 × 10 −18
Zeng, M., Huang, Y., Zhang, B., Hao, Y., Ma, Z., Hu, R., Zhang, H., Chen, Z., Wang, M., Guan, H., et al. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.064004 · Cited by 23
A proof-of-concept model of compact and high-performance 87Sr optical lattice clock for space
Guo, F., Tan, W., Zhou, C.-H., Xia, J., Chen, Y.-X., Liang, T., Liu, Q., Liu, Y., He, D.-J., Zhou, Y.-Z., et al. (2021) · AIP Advances · doi:10.1063/5.0064087 · Cited by 16
Laboratory demonstration of geopotential measurement using transportable optical clocks
Liu, D.-X., Cao, J., Yuan, J.-B., Cui, K.-F., Yuan, Y., Zhang, P., Chao, S.-J., Shu, H.-L., & Huang, X.-R. (2023) · Chinese Physics B · doi:10.1088/1674-1056/ac6337 · Cited by 10 · cited 1×
“Previously, extremely small redshifts have been resolved with optical clocks [12, 13] by differential observations in a single apparatus.”
End-to-end topology for fiber comb based optical frequency transfer at the 10−21 level: erratum
Benkler, E., Lipphardt, B., Puppe, T., Wilk, R., Rohde, F., & Sterr, U. (2020) · Optics Express · doi:10.1364/oe.394163 · Cited by 6
Self-citationAn Optical Lattice Clock with Fermionic and Bosonic Sr Atoms
Baillard, X., Fouché, M., Targat, R. L., Westergaard, P. G., Lecallier, A., Chapelet, F., Bize, S., Rosenbusch, P., Abgrall, M., Laurent, P., et al. (2007) · Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR) · doi:10.1109/cleopr.2007.4391551
Self-citation
Research works printed but not linked: 1
- M. Vermeer, 1983, Chronometric Levelling
Cited by
Coordinated international comparisons between optical clocks connected via fiber and satellite links
Lindvall, T., Pizzocaro, M., Godun, R. M., Abgrall, M., Akamatsu, D., Amy‐Klein, A., Benkler, E., Bhatt, N., Calonico, D., Cantin, E., et al. (2025) · Optica · doi:10.1364/optica.561754 · Cited by 37
“Discrepancies between Sr clocks have also been seen in other measurement campaigns [19,49] but the coordinated set of frequency ratios recorded here provides further insight.”
Self-citationNTSC SrII optical lattice clock with uncertainty of 2 × 10 − 18
Lu, X., Guo, F., Liu, Y., Cao, J., Li, J., Xia, J., Xu, Q., Lu, B., Wang, Y., & Chang, H. (2025) · Metrologia · doi:10.1088/1681-7575/addc77 · Cited by 23
GHZ protocols enhance frequency metrology despite spontaneous decay
Kielinski, T., Schmidt, P. O., & Hammerer, K. (2024) · Science Advances · doi:10.1126/sciadv.adr1439 · Cited by 17
“This unprecedented performance opens the path towards new applications in fundamental research and technology, such as the redefinition of the SI second [1], relativistic geodesy [16–19], tests of general relativity [14, 20–24] and the search for physics beyond the standard model [25–27].”
Perspective: Practical atom-based quantum sensors
Brown, J. M., & Walker, T. G. (2025) · Physical Review A · doi:10.1103/q6d1-594v · Cited by 20
Geopotential Difference Measurement Using Two Transportable Optical Clocks’ Frequency Comparisons
Liu, D., Wu, L. F., Xiong, C., & Bao, L. (2024) · Remote Sensing · doi:10.3390/rs16132462 · Cited by 11
Metadata
- Authors
- Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., Koke, S., Benkler, E., Giunta, M., Maisenbacher, L., Matveev, A., Dörscher, S., Schwarz, R., Al-Masoudi, A., Hänsch, T. W., Udem, T., Holzwarth, R., & Lisdat, C.
- Affiliations
- Physikalisch-Technische Bundesanstalt (DE)
- Leibniz University Hannover (DE)
- Max Planck Institute of Quantum Optics (DE)
- Physikalisch-Technische Bundesanstalt
- Menlo Systems (Germany) (DE)
- Max-Planck-Institut für Quantenoptik
- ORCID
- Venue
- Physical Review Applied
- Publisher
- American Physical Society (APS)
- Published
- 2024-06-03
- Volume
- 21
- Issue
- 6
- ISSN
- 2331-7019 (ISSN-L)
- OpenAlex
- W4399285623
- Cited by
- 33
- References
- 67
- Citations by year
- 2026: 8 · 2025: 18 · 2024: 6
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Physical Review Applied (publishedVersion, cc-by)
- arXiv (Cornell University) (submittedVersion)
- Institutional Repository of Leibniz Universität Hannover (Leibniz Universität Hannover) (submittedVersion, cc-by-nc-nd)
- arXiv (Cornell University)
- Leibniz Universität Hannover (cc-by)
- Funders
- Deutsche Forschungsgemeinschaft
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
- Physical Sciences › Earth and Planetary Sciences › Geophysics › Geophysics and Gravity Measurements
- Keywords
- geopotential difference, optical lattice clock, 87Sr, gravitational redshift, gravimetric analysis, height determination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-01, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-01 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.