The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Measuring adhesion, attraction, and repulsion between surfaces in liquids with an atomic-force microscope
Open accessAbstract
Understanding the forces such as adhesion, attraction, and repulsion between surfaces and liquids is the key not only to understanding phenomena such as lubrication and indentation but also the key to understanding how best to operate an atomic-force microscope (AFM). In this paper, we examined the cases of an insulating tip on an insulating sample (silicon nitride tip on mica) and of a conducting tip on a conducting sample (tungsten carbide tip on a gold or platinum foil). The force-versus-distance curves for these two limiting systems were very different in different liquids. In ethanol, the curve is just what one would expect theoretically: a slightly attractive force before contact, a jump into contact, then a small pull-out force, about 0.2 nN for an insulating tip on the insulating surface and about 0.5 nN for two conducting surfaces. In pure water, the behavior is complex and variable. Pull-out forces vary from 0.2 to 1.5 nN for two insulating surfaces. For two conducting surfaces the force-versus-distance curves show large pull-out forces of order of 10 nN. These large forces are probably due to adsorption contamination layers on the metal surfaces that are not removed by the solvent action of the pure water. These forces, however, can be reduced to less than one-hundredth of the original value by adding ethanol to the water. This makes ethanol a useful liquid for routine imaging of macromolecules such as DNA, proteins, and polymers, that have been adsorbed to a substrate and that must be imaged at low force. In formamide, we observed a predicted repulsive interaction in the nontouching regime for insulating surfaces as predicted by Hartmann. In different concentrations of KCl aqueous solution, we observed again a repulsive interaction in the nontouching regime due to double-layer repulsion of charged surfaces across ionic solutions. The measured Debye length agrees well with the theoretical prediction. And last, the dependence of the pull-out force on the indentation in water has been investigated. The more the tip indents the sample surface in a force-versus-distance cycle, the larger the pull-out force will be. This shows also the usefulness of the AFM for investigations of micromechanical properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Israelachvili, J. N., & Adams, G. E. (1978) · Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases · doi:10.1039/f19787400975 · Cited by 1,812
Clavilier, J., Faure, R., Guinet, G., & Durand, R. (1980) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(79)80022-4 · Cited by 1,503
Atomistic Mechanisms and Dynamics of Adhesion, Nanoindentation, and Fracture
Landman, U., Luedtke, W. D., Burnham, N. A., & Colton, R. J. (1990) · Science · doi:10.1126/science.248.4954.454 · Cited by 1,145
Imaging Crystals, Polymers, and Processes in Water with the Atomic Force Microscope
Drake, B., Prater, C. B., Weisenhorn, A. L., Gould, S. A. C., Albrecht, T. R., Quate, C. F., Cannell, D. S., Hansma, H. G., & Hansma, P. K. (1989) · Science · doi:10.1126/science.2928794 · Cited by 1,033
Self-citationIntermolecular and Surface Forces
(2011) · doi:10.1016/c2009-0-21560-1 · Cited by 871
Butt, H.-J. (1991) · Biophysical Journal · doi:10.1016/s0006-3495(91)82180-4 · Cited by 805
Self-citationMicrofabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576520 · Cited by 747
Scanning Tunneling Microscopy and Atomic Force Microscopy: Application to Biology and Technology
Hansma, P. K., Elings, V. B., Marti, O., & Bracker, C. E. (1988) · Science · doi:10.1126/science.3051380 · Cited by 716
Self-citationBurnham, N. A., & Colton, R. J. (1989) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.576168 · Cited by 651
Forces in atomic force microscopy in air and water
Weisenhorn, A. L., Hansma, P. K., Albrecht, T. R., & Quate, C. F. (1989) · Applied Physics Letters · doi:10.1063/1.101024 · Cited by 632
Self-citationRugar, D., & Hansma, P. (1990) · Physics Today · doi:10.1063/1.881238 · Cited by 589
Self-citationAtomic Resolution with Atomic Force Microscope
Binnig, G., Gerber, C., Stoll, E., Albrecht, T. R., & Quate, C. F. (1987) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/3/12/006 · Cited by 559
Tip Surface Interactions in STM and AFM
Pethica, J. B., & Oliver, W. C. (1987) · Physica Scripta · doi:10.1088/0031-8949/1987/t19a/010 · Cited by 388
Electrostatic interaction in atomic force microscopy
Butt, H.-J. (1991) · Biophysical Journal · doi:10.1016/s0006-3495(91)82112-9 · Cited by 230
Self-citationAtomic force microscopy of polymeric liquid films
Mate, C. M., Lorenz, M. R., & Novotny, V. J. (1989) · The Journal of Chemical Physics · doi:10.1063/1.456188 · Cited by 228
Observation of metallic adhesion using the scanning tunneling microscope
Dürig, U., Züger, O., & Pohl, D. W. (1990) · Physical Review Letters · doi:10.1103/physrevlett.65.349 · Cited by 182
Imaging and Manipulating Molecules on a Zeolite Surface with an Atomic Force Microscope
Weisenhorn, A. L., Dougall, J. E. M., Gould, S. A. C., Cox, S. D., WISE, W. S., Massié, J., Maivald, P., Elings, V. B., Stucky, G. D., & Hansma, P. K. (1990) · Science · doi:10.1126/science.247.4948.1330 · Cited by 144
Self-citationEffect of tip profile on atomic-force microscope images: A model study
ABRAHAM, F. F., Batra, I. P., & Çiraci, S. (1988) · Physical Review Letters · doi:10.1103/physrevlett.60.1314 · Cited by 130
The atomic force microscope: A tool for science and industry
Gould, S. A. C., Drake, B., Prater, C. B., Weisenhorn, A. L., Manne, S., Kelderman, G., Butt, H., Hansma, H. G., Hansma, P. K., Magonov, S., et al. (1990) · Ultramicroscopy · doi:10.1016/0304-3991(90)90011-a · Cited by 65
Self-citationForce measurement using an ac atomic force microscope
Ducker, W. A., Cook, R. F., & Clarke, D. R. (1990) · Journal of Applied Physics · doi:10.1063/1.344961 · Cited by 41
Cited by
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Self-citationForce Spectroscopy of Molecular Systems—Single Molecule Spectroscopy of Polymers and Biomolecules
Janshoff, A., Neitzert, M., Oberdörfer, Y., & Fuchs, H. (2000) · Angewandte Chemie · doi:10.1002/1521-3773(20000915)39:18<3212::aid-anie3212>3.0.co;2-x · Cited by 502
Noy, A., Vezenov, D. V., & Lieber, C. M. (1997) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.27.1.381 · Cited by 478
Stolz, M., Raiteri, R., Daniels, A. U., VanLandingham, M. R., Baschong, W., & Aebi, U. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74375-1 · Cited by 454
McLean, R. S., & Sauer, B. B. (1997) · Macromolecules · doi:10.1021/ma970350e · Cited by 356
Metadata
- Authors
- Weisenhorn, A. L., Maivald, P., Butt, H.-J., & Hansma, P. K.
- Venue
- Physical Review B
- Publisher
- American Physical Society (APS)
- Published
- 1992-05-15
- Volume
- 45
- Issue
- 19
- Pages
- 11226-11232
- ISSN
- 0163-1829 (ISSN-L)
- 1095-3795
- OpenAlex
- W1988080373
- Cited by
- 485
- References
- 21
- FWCI
- 15.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.