Operational Magic Intensity for Sr Optical Lattice Clocks
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
We experimentally investigate the lattice-induced light shift by the electric-quadrupole (E2) and magnetic-dipole (M1) polarizabilities and the hyperpolarizability in Sr optical lattice clocks. Precise control of the axial as well as the radial motion of atoms in a one-dimensional lattice allows observing the E2-M1 polarizability difference. Measured polarizabilities determine an operational lattice depth to be 72(2)E_{R}, where the total light shift cancels to the 10^{-19} level, over a lattice-intensity variation of about 30%. This operational trap depth and its allowable intensity range conveniently coincide with experimentally feasible operating conditions for Sr optical lattice clocks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., et al. (2015) · Nature Communications · doi:10.1038/ncomms7896 · Cited by 780
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Self-citationHunting for topological dark matter with atomic clocks
Derevianko, A., & Pospelov, M. (2014) · Nature Physics · doi:10.1038/nphys3137 · Cited by 522
A clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460
Gravitational wave detection with optical lattice atomic clocks
Kolkowitz, S., Pikovski, I., Langellier, N., Lukin, M. D., Walsworth, R. L., & Ye, J. (2016) · Physical Review D · doi:10.1103/physrevd.94.124043 · Cited by 396
The CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Experimental realization of an optical second with strontium lattice clocks
Le Targat, R., Lorini, L., Le Coq, Y., Zawada, M., Guéna, J., Abgrall, M., Gurov, M., Rosenbusch, P., Rovera, D. G., Nagórny, B., et al. (2013) · Nature Communications · doi:10.1038/ncomms3109 · Cited by 250
Frequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221
Self-citationFrequency comparison of optical lattice clocks beyond the Dick limit
Takamoto, M., Takano, T., & Katori, H. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.34 · Cited by 154
Self-citation
Research works printed but not linked: 18
- 10.1103/PhysRevLett.104.070802 · DOI · Paper page
- 10.1038/nphoton.2016.159 · DOI · Paper page
- 10.1103/RevModPhys.75.403 · DOI · Paper page
- 10.1103/PhysRevLett.113.210802 · DOI · Paper page
- 10.1109/TIM.1982.6312526 · DOI · Paper page
- 10.1103/PhysRevLett.91.173005 · DOI · Paper page
- 10.1103/PhysRevLett.101.193601 · DOI · Paper page
- 10.1103/PhysRevLett.96.103003 · DOI · Paper page
- 10.1103/PhysRevA.93.043420 · DOI
- 10.1103/PhysRevLett.120.063204 · DOI
- 10.1103/PhysRevLett.106.210801 · DOI · Paper page
- 10.1103/PhysRevLett.100.103002 · DOI · Paper page
- 10.1103/PhysRevLett.114.230801 · DOI · Paper page
- 10.1103/PhysRevA.80.052703 · DOI · Paper page
- 10.1143/JPSJ.75.104302 · DOI · Paper page
- 10.1109/TUFFC.2012.2210 · DOI · Paper page
- 10.1103/PhysRevLett.68.2000 · doi:10.1103/physrevlett.68.2000
- 10.1103/PhysRevLett.82.1116 · DOI · Paper page
Cited by
Test of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Self-citationResolving the gravitational redshift across a millimetre-scale atomic sample
Bothwell, T., Kennedy, C. J., Aeppli, A., Kedar, D., Robinson, J. M., Oelker, E., Staron, A., & Ye, J. (2022) · Nature · doi:10.1038/s41586-021-04349-7 · Cited by 449
JILA SrI optical lattice clock with uncertainty of 2.0 × 10 − 18
Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J. (2019) · Metrologia · doi:10.1088/1681-7575/ab4089 · Cited by 324
“To constrain the lattice Stark shift at the 10−18 level, recent work has highlighted the importance of accounting for higher-order effects such as hyperpolarizability and the magnetic dipole and electric quadrupole terms [25, 26].”
BackgroundMethodResultInfluentialClock with 8 × 10 − 19 Systematic Uncertainty
Aeppli, A., Kim, K., Warfield, W., Safronova, M. S., & Ye, J. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.023401 · Cited by 211
Differential clock comparisons with a multiplexed optical lattice clock
Zheng, X., Dolde, J., Lochab, V., Merriman, B. N., Li, H., & Kolkowitz, S. (2022) · Nature · doi:10.1038/s41586-021-04344-y · Cited by 150
Ohmae, N., Takamoto, M., Takahashi, Y., Kokubun, M., Araki, K., Hinton, A., Ushijima, I., Muramatsu, T., Furumiya, T., Sakai, Y., et al. (2021) · Advanced Quantum Technologies · doi:10.1002/qute.202100015 · Cited by 79
Self-citationOptical frequency distribution using laser repeater stations with planar lightwave circuits
Akatsuka, T., Goh, T., Imai, H., Oguri, K., Ishizawa, A., Ushijima, I., Ohmae, N., Takamoto, M., Katori, H., Hashimoto, T., et al. (2020) · Optics Express · doi:10.1364/oe.383526 · Cited by 55
Self-citationA lab-based test of the gravitational redshift with a miniature clock network
Zheng, X., Dolde, J., Cambria, M. C., Lim, H. M., & Kolkowitz, S. (2023) · Nature Communications · doi:10.1038/s41467-023-40629-8 · Cited by 47
“This allows us to extract the operational lattice detuning from the effective magic wavelength 25,51 , and to independently evaluate the lattice light shift gradient upon removal of the δ u shifts (Fig.”
A perspective on the future of transportable optical lattice clocks
Takamoto, M., Tanaka, Y., & Katori, H. (2022) · Applied Physics Letters · doi:10.1063/5.0087894 · Cited by 40
Self-citationLong-distance chronometric leveling with a portable optical clock
Grotti, J., Nosske, I., Koller, S. B., Herbers, S., Denker, H., Timmen, L., Vishnyakova, G., Grosche, G., Waterholter, T., Kuhl, A., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.l061001 · Cited by 33
“The procedure remains unchanged from the one described in Ref.”
Exploring potential applications of optical lattice clocks in a plate subduction zone
Tanaka, Y., & Katori, H. (2021) · Journal of Geodesy · doi:10.1007/s00190-021-01548-y · Cited by 31
Self-citation
Metadata
- Authors
- Ushijima, I., Takamoto, M., & Katori, H.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2018-12-28
- Volume
- 121
- Issue
- 26
- Pages
- 263202-263202
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2907461682
- Cited by
- 111
- References
- 15
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- Funders
- Japan Science and Technology Agency (JPMJER1002 10102832)
- Japan Society for the Promotion of Science (JP16H06284)
- Ministry of Education, Culture, Sports, Science and Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.