The DOI matches its Crossref record.
Phase Coherent Vacuum-Ultraviolet to Radio Frequency Comparison with a Mode-Locked Laser
Abstract
We demonstrate a versatile new technique that provides a phase coherent link between optical frequencies and the radio frequency domain. The regularly spaced comb of modes of a mode-locked femtosecond laser is used as a precise ruler to measure a large frequency gap between two different multiples (harmonics or subharmonics) of a laser frequency. In this way, we have determined a new value of the hydrogen $1S\ensuremath{-}2S$ two-photon resonance, ${f}_{1S\ensuremath{-}2S}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}2466061413187.29(37)\phantom{\rule{0ex}{0ex}}\mathrm{kHz}$, representing now the most accurate measurement of an optical frequency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 24
- Th. Udem, 1997, Phys. Rev. Lett., 79, 2646, 10.1103/PhysRevLett.79.2646 · DOI · Paper page
- F. Riehle, 1999, IEEE Trans. Instrum. Meas., 48, 613, 10.1109/19.769670 · doi:10.1109/19.769670
- H. Schnatz, 1996, Phys. Rev. Lett., 76, 18, 10.1103/PhysRevLett.76.18 · DOI · Paper page
- G. Santarelli, 1999, Phys. Rev. Lett., 82, 4619, 10.1103/PhysRevLett.82.4619 · DOI · Paper page
- A. Huber, 1998, Phys. Rev. Lett., 80, 468, 10.1103/PhysRevLett.80.468 · DOI · Paper page
- J. Eades, 1999, Rev. Mod. Phys., 71, 373, 10.1103/RevModPhys.71.373 · DOI
- Th. Udem, 1999, Phys. Rev. Lett., 82, 3568, 10.1103/PhysRevLett.82.3568 · DOI · Paper page
- Th. Udem, 1999, Opt. Lett., 24, 881, 10.1364/OL.24.000881 · DOI · Paper page
- D. McIntyre, 1988, Digest of the Annual Meeting of the Optical Society of America
- H. R. Telle, 1990, Opt. Lett., 15, 532, 10.1364/OL.15.000532 · DOI · Paper page
- E. Peik, 1999, Proceedings of the 13th European Frequency and Time Forum and the 1999 IEEE International Frequency Control Symposium, Besançon
- J. N. Eckstein, 1978, Phys. Rev. Lett., 40, 847, 10.1103/PhysRevLett.40.847 · DOI · Paper page
- V. P. Chebotaev, 1990, Appl. Phys. B, 50, 1, 10.1007/BF00330084 · doi:10.1007/bf00330084
- J. Reichert, 1999, Opt. Commun., 172, 59, 10.1016/S0030-4018(99)00491-5 · DOI · Paper page
- J. K. Ranka, 2000, Opt. Lett., 25, 25, 10.1364/OL.25.000025 · DOI · Paper page
- M. Bellini, 1998, Phys. Rev. Lett., 81, 297, 10.1103/PhysRevLett.81.297 · DOI
- M. Prevedelli, 1995, Appl. Phys. B, 60, S241
- C. Zimmermann, 1990, Phys. Rev. Lett., 65, 571, 10.1103/PhysRevLett.65.571 · doi:10.1103/physrevlett.65.571
- F. Schmidt-Kaler, 1995, Phys. Rev. A, 51, 2789, 10.1103/PhysRevA.51.2789 · doi:10.1103/physreva.51.2789
- A. Huber, 1999, Phys. Rev. A, 59, 1844, 10.1103/PhysRevA.59.1844 · DOI
- T. C. Killian, 1998, Phys. Rev. Lett., 81, 3807, 10.1103/PhysRevLett.81.3807 · DOI · Paper page
- L. Essen, 1971, Nature (London), 229, 110, 10.1038/229110a0 · DOI · Paper page
- J. W. Heberle, 1956, Phys. Rev., 101, 612, 10.1103/PhysRev.101.612 · DOI
- D. Taqqu, 1999, Hyperfine Interact., 119, 311, 10.1023/A:1012676517972 · doi:10.1023/a:1012676517972
Cited by
Udem, T., Holzwarth, R., & Hänsch, T. W. (2002) · Nature · doi:10.1038/416233a · Cited by 3,111
Self-citationCODATA recommended values of the fundamental physical constants: 2010
Mohr, P. J., Taylor, B. N., & Newell, D. B. (2012) · Reviews of Modern Physics · doi:10.1103/revmodphys.84.1527 · Cited by 2,441
Optical frequency comb generation from a monolithic microresonator
Del’Haye, P., Schliesser, A., Arcizet, O., Wilken, T., Holzwarth, R., & Kippenberg, T. J. (2007) · Nature · doi:10.1038/nature06401 · Cited by 2,290
Self-citationOptical Frequency Synthesizer for Precision Spectroscopy
Holzwarth, R., Udem, T., Hänsch, T. W., Knight, J. C., Wadsworth, W. J., & Russell, P. S. J. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.2264 · Cited by 1,225
Self-citationNobel Lecture: Passion for precision
Hänsch, T. W. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1297 · Cited by 915
Self-citationAn Optical Clock Based on a Single Trapped 199 Hg + Ion
Diddams, S. A., Udem, T., Bergquist, J. C., Curtis, E. A., Drullinger, R. E., Hollberg, L., Itano, W. M., Lee, W. D., Oates, C. W., Vogel, K. R., et al. (2001) · Science · doi:10.1126/science.1061171 · Cited by 720
Self-citationCODATA recommended values of the fundamental physical constants: 2002
Mohr, P. J., & Taylor, B. N. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.1 · Cited by 654
Nobel Lecture: Defining and measuring optical frequencies
Hall, J. L. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.1279 · Cited by 614
Niering, M., Holzwarth, R., Reichert, J., Pokasov, P., Udem, T., Weitz, M., Hänsch, T. W., Lemonde, P., Santarelli, G., Abgrall, M., et al. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5496 · Cited by 560
Self-citationMeasuring the frequency of light with mode-locked lasers
Reichert, J., Holzwarth, R., Udem, T., & Hänsch, T. W. (1999) · Optics Communications · doi:10.1016/s0030-4018(99)00491-5 · Cited by 473
Self-citationControlling the Phase Evolution of Few-Cycle Light Pulses
Apolonski, A., Poppe, A., Tempea, G., Spielmann, C., Udem, T., Holzwarth, R., Hänsch, T. W., & Krausz, F. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.740 · Cited by 472
Self-citationGeneration of 5-fs pulses and octave-spanning spectra directly from a Ti:sapphire laser
Ell, R., Morgner, U., Kärtner, F. X., Fujimoto, J. G., Ippen, E. P., Scheuer, V., Angelow, G., Tschudi, T., Lederer, M. J., Boiko, A., et al. (2001) · Optics Letters · doi:10.1364/ol.26.000373 · Cited by 470
Parriaux, A., Hammani, K., & Millot, G. (2020) · Advances in Optics and Photonics · doi:10.1364/aop.382052 · Cited by 385
Precision physics of simple atoms: QED tests, nuclear structure and fundamental constants
Karshenboim, S. G. (2005) · Physics Reports · doi:10.1016/j.physrep.2005.08.008 · Cited by 383
Sub-dekahertz Ultraviolet Spectroscopy of199Hg+
Rafac, R. J., Young, B. C., Beall, J. A., Itano, W. M., Wineland, D. J., & Bergquist, J. C. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.2462 · Cited by 266
Optical frequency synthesis based on mode-locked lasers
Cundiff, S. T., Ye, J., & Hall, J. L. (2001) · Review of Scientific Instruments · doi:10.1063/1.1400144 · Cited by 261
Absolute Frequency Measurements of theHg+and Ca Optical Clock Transitions with a Femtosecond Laser
Udem, T., Diddams, S. A., Vogel, K. R., Oates, C. W., Curtis, E. A., Lee, W. D., Itano, W. M., Drullinger, R. E., Bergquist, J. C., & Hollberg, L. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4996 · Cited by 260
Self-citationBase units of the SI, fundamental constants and modern quantum physics
Bordé, C. J. (2005) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2005.1635 · Cited by 124
Balling, P., Mašika, P., Křen, P., & Doležal, M. (2012) · Measurement Science and Technology · doi:10.1088/0957-0233/23/9/094001 · Cited by 66
Determination of the geopotential and orthometric height based on frequency shift equation
Shen, W., Ning, J., Liu, J., Li, J., & Chao, D. (2011) · Natural Science · doi:10.4236/ns.2011.35052 · Cited by 26
Metadata
- Authors
- Reichert, J., Niering, M., Holzwarth, R., Weitz, M., Udem, T., & Hänsch, T. W.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2000-04-10
- Volume
- 84
- Issue
- 15
- Pages
- 3232-3235
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1966518403
- Cited by
- 240
- References
- 0
- FWCI
- 14.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.