The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Scanning Probe-Based Frequency-Dependent Microrheology of Polymer Gels and Biological Cells
Open accessAbstract
A new scanning probe-based microrheology approach is used to quantify the frequency-dependent viscoelastic behavior of both fibroblast cells and polymer gels. The scanning probe shape was modified using polystyrene beads for a defined surface area nondestructively deforming the sample. An extended Hertz model is introduced to measure the frequency-dependent storage and loss moduli even for thin cell samples. Control measurements of the polyacrylamide gels compare well with conventional rheological data. The cells show a viscoelastic signature similar to in vitro actin gels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LANDAU, L. D., & LIFSHITZ, E. M. (1951) · Cited by 5,903
Sneddon, I. N. (1965) · International Journal of Engineering Science · doi:10.1016/0020-7225(65)90019-4 · Cited by 4,346
Theory of Elasticity: Vol. 7 of Course of Theoretical Physics
Landau, L. D., Lifshitz, E. M., Sykes, J. B., Reid, W. H., & Dill, E. H. (1960) · Physics Today · doi:10.1063/1.3057037 · Cited by 1,075
Measuring the viscoelastic properties of human platelets with the atomic force microscope
Radmacher, M., Fritz, M., Kacher, C. M., Cleveland, J. P., & Hansma, P. K. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79602-9 · Cited by 839
Elasticity of normal and cancerous human bladder cells studied by scanning force microscopy
Lekka, M., Laidler, P., Gil, D., Lekki, J., Stachura, Z., & Hrynkiewicz, A. Z. (1999) · European Biophysics Journal · doi:10.1007/s002490050213 · Cited by 748
Burnham, N. A., & Colton, R. J. (1989) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.576168 · Cited by 651
Measuring the Elastic Properties of Thin Polymer Films with the Atomic Force Microscope
Domke, J., & Radmacher, M. (1998) · Langmuir · doi:10.1021/la9713006 · Cited by 636
Relative Microelastic Mapping of Living Cells by Atomic Force Microscopy
A-Hassan, E., Heinz, W. F., Antonik, M. D., D’Costa, N. P., Nageswaran, S., Schoenenberger, C.-A., & Hoh, J. H. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77868-3 · Cited by 552
Mechanics of Living Cells Measured by Laser Tracking Microrheology
Yamada, S., Wirtz, D., & Kuo, S. C. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76725-7 · Cited by 517
Rotsch, C., Jacobson, K., & Radmacher, M. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.3.921 · Cited by 437
Cited by
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
Guck, J., Schinkinger, S., Lincoln, B., Wottawah, F., Ebert, S., Romeyke, M., Lenz, D., Erickson, H. M., Ananthakrishnan, R., Mitchell, D., et al. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.045476 · Cited by 1,417
Self-citationScaling the Microrheology of Living Cells
Fabry, B., Maksym, G. N., Butler, J. P., Glogauer, M., Navajas, D., & Fredberg, J. J. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.148102 · Cited by 1,261
Determination of Elastic Moduli of Thin Layers of Soft Material Using the Atomic Force Microscope
Dimitriadis, E. K., Horkay, F., Maresca, J., Kachar, B., & Chadwick, R. S. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75620-8 · Cited by 1,230
Substrate Compliance versus Ligand Density in Cell on Gel Responses
Engler, A., Bacakova, L., Newman, C., Hategan, A., Griffin, M., & Discher, D. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74140-5 · Cited by 1,141
The Optical Stretcher: A Novel Laser Tool to Micromanipulate Cells
Guck, J., Ananthakrishnan, R., Mahmood, H., Moon, T. J., Cunningham, C. C., & Käs, J. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)75740-2 · Cited by 977
Self-citationEngler, A. J., Carag-Krieger, C., Johnson, C. P., Raab, M., Tang, H.-Y., Speicher, D. W., Sanger, J. W., Sanger, J. M., & Discher, D. E. (2008) · Journal of Cell Science · doi:10.1242/jcs.029678 · Cited by 865
Atomic force microscopy-based mechanobiology
Krieg, M., Fläschner, G., Alsteens, D., Gaub, B. M., Roos, W. H., Wuite, G. J. L., Gaub, H. E., Gerber, C., Dufrêne, Y. F., & Müller, D. J. (2018) · Nature Reviews Physics · doi:10.1038/s42254-018-0001-7 · Cited by 799
Atomic force microscopy probing of cell elasticity
Kuznetsova, T. G., Starodubtseva, M. N., Yegorenkov, N. I., Chizhik, S. A., & Zhdanov, R. I. (2007) · Micron · doi:10.1016/j.micron.2007.06.011 · Cited by 794
Microrheology of Human Lung Epithelial Cells Measured by Atomic Force Microscopy
Alcaraz, J., Buscemi, L., Grabulosa, M., Trepat, X., Fabry, B., Farré, R., & Navajas, D. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)75014-0 · Cited by 740
Mechanical models for living cells—a review
Lim, C. T., Zhou, E. H., & Quek, S. T. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.12.008 · Cited by 719
Indentation Versus Tensile Measurements of Young's Modulus for Soft Biological Tissues
McKee, C. T., Last, J. A., Russell, P., & Murphy, C. J. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0520 · Cited by 708
Microtubules can bear enhanced compressive loads in living cells because of lateral reinforcement
Brangwynne, C. P., MacKintosh, F. C., Kumar, S., Geisse, N. A., Talbot, J., Mahadevan, L., Parker, K. K., Ingber, D. E., & Weitz, D. A. (2006) · The Journal of Cell Biology · doi:10.1083/jcb.200601060 · Cited by 700
Self-citationMesenchymal stem cell injection after myocardial infarction improves myocardial compliance
Berry, M. F., Engler, A. J., Woo, Y. J., Pirolli, T. J., Bish, L. T., Jayasankar, V., Morine, K. J., Gardner, T. J., Discher, D. E., & Sweeney, H. L. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01017.2005 · Cited by 690
Mechanosensing is critical for axon growth in the developing brain
Koser, D. E., Thompson, A. J., Foster, S. K., Dwivedy, A., Pillai, E. K., Sheridan, G. K., Svoboda, H., Viana, M., Costa, L. D. F., Guck, J., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4394 · Cited by 649
Microrheology of complex fluids
Waigh, T. A. (2005) · Reports on Progress in Physics · doi:10.1088/0034-4885/68/3/r04 · Cited by 652
Mathur, A. B., Collinsworth, A. M., Reichert, W. M., Kraus, W. E., & Truskey, G. A. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00149-x · Cited by 589
Viscoelastic properties of individual glial cells and neurons in the CNS
Lu, Y.-B., Franze, K., Seifert, G., Steinhäuser, C., Kirchhoff, F., Wolburg, H., Guck, J., Janmey, P., Wei, E.-Q., Käs, J., et al. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606150103 · Cited by 578
Self-citationForce Microscopy of Nonadherent Cells: A Comparison of Leukemia Cell Deformability
Rosenbluth, M. J., Lam, W. A., & Fletcher, D. A. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.067496 · Cited by 532
Biomechanics approaches to studying human diseases
Lee, G. Y. H., & Lim, C. T. (2007) · Trends in Biotechnology · doi:10.1016/j.tibtech.2007.01.005 · Cited by 485
Garcia, R. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00318b · Cited by 480
Mahaffy, R. E., Park, S., Gerde, E., Käs, J., & Shih, C. K. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74245-9 · Cited by 460
Self-citationAge-related vascular stiffening: causes and consequences
Kohn, J. C., Lampi, M. C., & Reinhart-King, C. A. (2015) · Frontiers in Genetics · doi:10.3389/fgene.2015.00112 · Cited by 440
“Data can be fit to standard mathematical models such as the Hertz model, to provide mechanical properties such as the elastic modulus at the indentation location (Hertz, 1881; Mahaffy et al., 2000; Peloquin et al., 2011).”
MethodThe influence of substrate creep on mesenchymal stem cell behaviour and phenotype
Cameron, A. R., Frith, J. E., & Cooper-White, J. J. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.003 · Cited by 428
A single-cell-based model of tumor growth in vitro: monolayers and spheroids
Drasdo, D., & Höhme, S. (2005) · Physical Biology · doi:10.1088/1478-3975/2/3/001 · Cited by 421
Rico, F., Roca-Cusachs, P., Gavara, N., Farré, R., Rotger, M., & Navajas, D. (2005) · Physical Review E · doi:10.1103/physreve.72.021914 · Cited by 421
Discrimination Between Normal and Cancerous Cells Using AFM
Lekka, M. (2016) · BioNanoScience · doi:10.1007/s12668-016-0191-3 · Cited by 414
Reversible stress softening of actin networks
Chaudhuri, O., Parekh, S. H., & Fletcher, D. A. (2007) · Nature · doi:10.1038/nature05459 · Cited by 406
REHFELDT, F., ENGLER, A., ECKHARDT, A., AHMED, F., & DISCHER, D. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.007 · Cited by 405
Chen, D. T. N., Wen, Q., Janmey, P. A., Crocker, J. C., & Yodh, A. G. (2010) · Annual Review of Condensed Matter Physics · doi:10.1146/annurev-conmatphys-070909-104120 · Cited by 398
Mobility of Nonsticky Nanoparticles in Polymer Liquids
Cai, L.-H., Panyukov, S., & Rubinstein, M. (2011) · Macromolecules · doi:10.1021/ma201583q · Cited by 379
Time scale and other invariants of integrative mechanical behavior in living cells
Fabry, B., Maksym, G. N., Butler, J. P., Glogauer, M., Navajas, D., Taback, N. A., Millet, E. J., & Fredberg, J. J. (2003) · Physical Review E · doi:10.1103/physreve.68.041914 · Cited by 376
Engler, A. J., Richert, L., Wong, J. Y., Picart, C., & Discher, D. E. (2004) · Surface Science · doi:10.1016/j.susc.2004.06.179 · Cited by 370
A bottom-up approach to cell mechanics
Bausch, A. R., & Kroy, K. (2006) · Nature Physics · doi:10.1038/nphys260 · Cited by 360
Viscoelastic hydrogels for 3D cell culture
Chaudhuri, O. (2017) · Biomaterials Science · doi:10.1039/c7bm00261k · Cited by 353
Darling, E. M., Topel, M., Zauscher, S., Vail, T. P., & Guilak, F. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.06.019 · Cited by 349
Detyrosinated microtubules buckle and bear load in contracting cardiomyocytes
Robison, P., Caporizzo, M. A., Ahmadzadeh, H., Bogush, A. I., Chen, C. Y., Margulies, K. B., Shenoy, V. B., & Prosser, B. L. (2016) · Science · doi:10.1126/science.aaf0659 · Cited by 338
Viscoelastic properties of zonal articular chondrocytes measured by atomic force microscopy
Darling, E. M., Zauscher, S., & Guilak, F. (2006) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2005.12.003 · Cited by 329
Wong, J. Y., Leach, J. B., & Brown, X. Q. (2004) · Surface Science · doi:10.1016/j.susc.2004.06.186 · Cited by 323
Mechanical Heterogeneity of the Rat Hippocampus Measured by Atomic Force Microscope Indentation
Elkin, B. S., Azeloglu, E. U., Costa, K. D., & Morrison III, B. (2007) · Journal of Neurotrauma · doi:10.1089/neu.2006.0169 · Cited by 316
The elastic modulus of Matrigel™ as determined by atomic force microscopy
Soofi, S. S., Last, J. A., Liliensiek, S. J., Nealey, P. F., & Murphy, C. J. (2009) · Journal of Structural Biology · doi:10.1016/j.jsb.2009.05.005 · Cited by 309
Tuning the Range of Polyacrylamide Gel Stiffness for Mechanobiology Applications
Denisin, A. K., & Pruitt, B. L. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b09344 · Cited by 313
Individual-based and continuum models of growing cell populations: a comparison
Byrne, H., & Drasdo, D. (2009) · Journal of Mathematical Biology · doi:10.1007/s00285-008-0212-0 · Cited by 307
Broken detailed balance and non-equilibrium dynamics in living systems: a review
Gnesotto, F. S., Mura, F., Gladrow, J., & Broedersz, C. P. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab3ed · Cited by 295
High-frequency microrheology reveals cytoskeleton dynamics in living cells
Rigato, A., Miyagi, A., Scheuring, S., & Rico, F. (2017) · Nature Physics · doi:10.1038/nphys4104 · Cited by 281
Galle, J., Loeffler, M., & Drasdo, D. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.041459 · Cited by 269
Conducting polymer-hydrogels for medical electrode applications
Green, R. A., Baek, S., Poole-Warren, L. A., & Martens, P. J. (2010) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/11/1/014107 · Cited by 268
Studying the Mechanics of Cellular Processes by Atomic Force Microscopy
Radmacher, M. (2007) · Methods in Cell Biology · doi:10.1016/s0091-679x(07)83015-9 · Cited by 263
Reactive glial cells: increased stiffness correlates with increased intermediate filament expression
Lu, Y., Iandiev, I., Hollborn, M., Körber, N., Ulbricht, E., Hirrlinger, P. G., Pannicke, T., Wei, E., Bringmann, A., Wolburg, H., et al. (2011) · The FASEB Journal · doi:10.1096/fj.10-163790 · Cited by 172
“We have shown that the biomechanics of freshly dissociated glial cells can be studied by scanning force microscopy (SFM)-based cell rheology (17).”
BackgroundMethodInfluentialSelf-citationCandiello, J., Grandhi, T. S. P., Goh, S. K., Vaidya, V., Lemmon-Kishi, M., Eliato, K. R., Ros, R., Kumta, P. N., Rege, K., & Banerjee, I. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.05.031 · Cited by 146
Metadata
- Authors
- Mahaffy, R. E., Shih, C. K., MacKintosh, F. C., & Käs, J.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2000-07-24
- Volume
- 85
- Issue
- 4
- Pages
- 880-883
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2027052987
- Cited by
- 509
- References
- 13
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.