The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Nuclear Spin Gyroscope Based on an Atomic Comagnetometer
Open accessAbstract
We describe a nuclear spin gyroscope based on an alkali-metal--noble-gas comagnetometer. Optically pumped alkali-metal vapor is used to polarize the noble-gas atoms and detect their gyroscopic precession. Spin precession due to magnetic fields as well as their gradients and transients can be cancelled in this arrangement. The sensitivity is enhanced by using a high-density alkali-metal vapor in a spin-exchange relaxation free regime. With a $\mathrm{K}\mathrm{\text{\ensuremath{-}}}^{3}\mathrm{He}$ comagnetometer we demonstrate rotation sensitivity of $5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}7}\text{ }\text{ }\mathrm{rad}\text{ }{\mathrm{s}}^{\ensuremath{-}1}\text{ }{\mathrm{Hz}}^{\ensuremath{-}1/2}$, equivalent to a magnetic field sensitivity of $2.5\text{ }\text{ }\mathrm{fT}/{\mathrm{Hz}}^{1/2}$. The rotation signal can be increased by a factor of 10 using $^{21}\mathrm{Ne}$ with a smaller magnetic moment. The comagnetometer is also a promising tool in searches for anomalous spin couplings beyond the standard model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Self-citationHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Self-citationPrecision Rotation Measurements with an Atom Interferometer Gyroscope
Gustavson, T. L., Bouyer, P., & Kasevich, M. A. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.2046 · Cited by 785
A microfabricated atomic clock
Knappe, S. A., Shah, V., Schwindt, P. D. D., Hollberg, L. W., Kitching, J. E., Liew, L., & Moreland, J. (2004) · Applied Physics Letters · doi:10.1063/1.1787942 · Cited by 689
Rotation sensing with a dual atom-interferometer Sagnac gyroscope
Gustavson, T. L., Landragin, A., & Kasevich, M. A. (2000) · Classical and Quantum Gravity · doi:10.1088/0264-9381/17/12/311 · Cited by 470
Ring-laser tests of fundamental physics and geophysics
Stedman, G. E. (1997) · Reports on Progress in Physics · doi:10.1088/0034-4885/60/6/001 · Cited by 399
Limit on Lorentz and CPT Violation of the Neutron Using a Two-Species Noble-Gas Maser
Bear, D., Stoner, R. E., Walsworth, R. L., Kostelecký, V. A., & Lane, C. D. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.5038 · Cited by 309
Effective Operator Formalism in Optical Pumping
Happer, W., & Mathur, B. S. (1967) · Physical Review · doi:10.1103/physrev.163.12 · Cited by 248
Effects of spin-exchange collisions in a high-density alkali-metal vapor in low magnetic fields
Savukov, I. M., & Romalis, M. V. (2005) · Physical Review A · doi:10.1103/physreva.71.023405 · Cited by 232
Self-citationDynamics of Two Overlapping Spin Ensembles Interacting by Spin Exchange
Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.253002 · Cited by 229
Self-citationAtomic Electric Dipole Moment Measurement Using Spin Exchange Pumped Masers of129Xeand3He
Rosenberry, M. A., & Chupp, T. E. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.22 · Cited by 223
Can a Quantum Nondemolition Measurement Improve the Sensitivity of an Atomic Magnetometer?
Auzinsh, M. P., Budker, D., Kimball, D. F. J., Rochester, S., Stalnaker, J. E., Sushkov, A. O., & Yashchuk, V. V. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.173002 · Cited by 153
Physical problems of fiber gyroscopy based on the Sagnac effect
Andronova, I. A., & Malykin, G. B. (2002) · Physics-Uspekhi · doi:10.1070/pu2002v045n08abeh001073 · Cited by 100
The Nuclear Magnetic Resonance Gyroscope: a Review
Woodman, K. F., Franks, P. W., & Richards, M. D. (1987) · Journal of Navigation · doi:10.1017/s037346330000062x · Cited by 81
Bear, D., Stoner, R. E., Walsworth, R. L., Kostelecký, V. A., & Lane, C. D. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.209902 · Cited by 45
Electronic spin relaxation of the 4S122 state of K induced by K-He and K-Ne collisions
Franz, F. A., & Volk, C. H. (1982) · Physical Review A · doi:10.1103/physreva.26.85 · Cited by 26
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Self-citationSearch for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
Kitching, J. (2018) · Applied Physics Reviews · doi:10.1063/1.5026238 · Cited by 621
Subpicotesla atomic magnetometry with a microfabricated vapour cell
Shah, V., Knappe, S., Schwindt, P. D. D., & Kitching, J. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.201 · Cited by 415
Metadata
- Authors
- Kornack, T. W., Ghosh, R. K., & Romalis, M. V.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2005-11-29
- Volume
- 95
- Issue
- 23
- Pages
- 230801-230801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W1998320990
- Cited by
- 565
- References
- 16
- FWCI
- 2.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.