The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Single-Atom Optical Clock with High Accuracy
Abstract
For the past 50 years, atomic standards based on the frequency of the cesium ground-state hyperfine transition have been the most accurate time pieces in the world. We now report a comparison between the cesium fountain standard NIST-F1, which has been evaluated with an inaccuracy of about 4 x 10(-16), and an optical frequency standard based on an ultraviolet transition in a single, laser-cooled mercury ion for which the fractional systematic frequency uncertainty was below 7.2 x 10(-17). The absolute frequency of the transition was measured versus cesium to be 1,064,721,609,899,144.94 (97) Hz, with a statistically limited total fractional uncertainty of 9.1 x 10(-16) the most accurate absolute measurement of an optical frequency to date.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct Link between Microwave and Optical Frequencies with a 300 THz Femtosecond Laser Comb
Diddams, S. A., Jones, D. J., Ye, J., Cundiff, S. T., Hall, J. L., Ranka, J. K., Windeler, R. S., Holzwarth, R., Udem, T., & Hänsch, T. W. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5102 · Cited by 1,155
Self-citationAbsolute Optical Frequency Measurement of the CesiumD1Line with a Mode-Locked Laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3568 · Cited by 791
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Self-citationAn Optical Clock Based on a Single Trapped 199 Hg + Ion
Diddams, S. A., Udem, T., Bergquist, J. C., Curtis, E. A., Drullinger, R. E., Hollberg, L., Itano, W. M., Lee, W. D., Oates, C. W., Vogel, K. R., et al. (2001) · Science · doi:10.1126/science.1061171 · Cited by 720
Self-citationVisible Lasers with Subhertz Linewidths
Young, B. C., Cruz, F. C., Itano, W. M., & Bergquist, J. C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3799 · Cited by 605
Self-citationAccuracy evaluation of NIST-F1
Jefferts, S. R., Shirley, J., Parker, T. E., Heavner, T. P., Meekhof, D. M., Nelson, C., Levi, F., Costanzo, G., Marchi, A. D., Drullinger, R., et al. (2002) · Metrologia · doi:10.1088/0026-1394/39/4/1 · Cited by 402
Self-citationWynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
NIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Self-citationMonoion oscillator as potential ultimate laser frequency standard
Dehmelt, H. G. (1982) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1982.6312526 · Cited by 323
Optical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A. (2004) · Science · doi:10.1126/science.1095092 · Cited by 319
Self-citation
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Self-citationAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Molecular fingerprinting with the resolved modes of a femtosecond laser frequency comb
Diddams, S. A., Hollberg, L., & Mbele, V. (2007) · Nature · doi:10.1038/nature05524 · Cited by 805
Self-citationSr Lattice Clock at 1 × 10 –16 Fractional Uncertainty by Remote Optical Evaluation with a Ca Clock
Ludlow, A. D., Zelevinsky, T., Campbell, G. K., Blatt, S., Boyd, M. M., de Miranda, M. H. G., Martin, M. J., Thomsen, J. W., Foreman, S. M., Ye, J., et al. (2008) · Science · doi:10.1126/science.1153341 · Cited by 554
Self-citationNobel Lecture: Superposition, entanglement, and raising Schrödinger’s cat
Wineland, D. J. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.1103 · Cited by 503
Theory and applications of atomic and ionic polarizabilities
Mitroy, J., Safronova, M. S., & Clark, C. W. (2010) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/0953-4075/43/20/202001 · Cited by 489
Testing General Relativity with Atom Interferometry
Dimopoulos, S., Graham, P. W., Hogan, J. M., & Kasevich, M. A. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.111102 · Cited by 362
Atomic gravitational wave interferometric sensor
Dimopoulos, S., Graham, P. W., Hogan, J. M., Kasevich, M. A., & Rajendran, S. (2008) · Physical Review D · doi:10.1103/physrevd.78.122002 · Cited by 335
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
Search for Ultralight Scalar Dark Matter with Atomic Spectroscopy
Van Tilburg, K., Leefer, N., Bougas, L., & Budker, D. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.011802 · Cited by 253
Fortier, T. M., Ashby, N., Bergquist, J. C., Delaney, M. J., Diddams, S. A., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Kim, K., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.070801 · Cited by 226
Self-citationNuclear spin effects in optical lattice clocks
Boyd, M. M., Zelevinsky, T., Ludlow, A. D., Blatt, S., Zanon-Willette, T., Foreman, S. M., & Ye, J. (2007) · Physical Review A · doi:10.1103/physreva.76.022510 · Cited by 186
Metadata
- Authors
- Oskay, W. H., Diddams, S. A., Donley, E. A., Fortier, T. M., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Delaney, M. J., Kim, K., Levi, F., Parker, T. E., & Bergquist, J. C.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2006-07-14
- Volume
- 97
- Issue
- 2
- Pages
- 020801-020801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2083197100
- Cited by
- 297
- References
- 26
- FWCI
- 31.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.