The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Single-Atom Optical Clock with High Accuracy
Abstract
For the past 50 years, atomic standards based on the frequency of the cesium ground-state hyperfine transition have been the most accurate time pieces in the world. We now report a comparison between the cesium fountain standard NIST-F1, which has been evaluated with an inaccuracy of about 4 x 10(-16), and an optical frequency standard based on an ultraviolet transition in a single, laser-cooled mercury ion for which the fractional systematic frequency uncertainty was below 7.2 x 10(-17). The absolute frequency of the transition was measured versus cesium to be 1,064,721,609,899,144.94 (97) Hz, with a statistically limited total fractional uncertainty of 9.1 x 10(-16) the most accurate absolute measurement of an optical frequency to date.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct Link between Microwave and Optical Frequencies with a 300 THz Femtosecond Laser Comb
Diddams, S. A., Jones, D. J., Ye, J., Cundiff, S. T., Hall, J. L., Ranka, J. K., Windeler, R. S., Holzwarth, R., Udem, T., & Hänsch, T. W. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.5102 · Cited by 1,155
Self-citationAbsolute Optical Frequency Measurement of the CesiumD1Line with a Mode-Locked Laser
Udem, T., Reichert, J., Holzwarth, R., & Hänsch, T. W. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3568 · Cited by 791
Minimization of ion micromotion in a Paul trap
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Journal of Applied Physics · doi:10.1063/1.367318 · Cited by 720
Self-citationAn Optical Clock Based on a Single Trapped 199 Hg + Ion
Diddams, S. A., Udem, T., Bergquist, J. C., Curtis, E. A., Drullinger, R. E., Hollberg, L., Itano, W. M., Lee, W. D., Oates, C. W., Vogel, K. R., et al. (2001) · Science · doi:10.1126/science.1061171 · Cited by 720
Self-citationVisible Lasers with Subhertz Linewidths
Young, B. C., Cruz, F. C., Itano, W. M., & Bergquist, J. C. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.3799 · Cited by 605
Self-citationAccuracy evaluation of NIST-F1
Jefferts, S. R., Shirley, J., Parker, T. E., Heavner, T. P., Meekhof, D. M., Nelson, C., Levi, F., Costanzo, G., Marchi, A. D., Drullinger, R., et al. (2002) · Metrologia · doi:10.1088/0026-1394/39/4/1 · Cited by 402
Self-citationWynands, R., & Weyers, S. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s08 · Cited by 374
NIST-F1: recent improvements and accuracy evaluations
Heavner, T. P., Jefferts, S. R., Donley, E. A., Shirley, J. H., & Parker, T. E. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/012 · Cited by 355
Self-citationMonoion oscillator as potential ultimate laser frequency standard
Dehmelt, H. G. (1982) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.1982.6312526 · Cited by 323
Optical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A. (2004) · Science · doi:10.1126/science.1095092 · Cited by 319
Self-citationAn Atomic Standard of Frequency and Time Interval: A Cæsium Resonator
ESSEN, L., & PARRY, J. V. L. (1955) · Nature · doi:10.1038/176280a0 · Cited by 305
Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion
Margolis, H. S., Barwood, G. P., Huang, G., Klein, H. A., Lea, S. N., Szymaniec, K., & Gill, P. (2004) · Science · doi:10.1126/science.1105497 · Cited by 301
Limit on the Present Temporal Variation of the Fine Structure Constant
Peik, E., Lipphardt, B., Schnatz, H., Schneider, T., Tamm, C., & Karshenboim, S. G. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.170801 · Cited by 282
Testing the Stability of Fundamental Constants with theHg+199Single-Ion Optical Clock
Bize, S., Diddams, S. A., Tanaka, U., Tanner, C. E., Oskay, W. H., Drullinger, R. E., Parker, T. E., Heavner, T. P., Jefferts, S. R., Hollberg, L., et al. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.150802 · Cited by 249
Self-citationExternal-field shifts of the 199-Hg(+) optical frequency standard
Itano, W. M. (2000) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.105.065 · Cited by 221
Self-citationParker, T. E., Jefferts, S. R., Heavner, T. P., & Donley, E. A. (2005) · Metrologia · doi:10.1088/0026-1394/42/5/013 · Cited by 220
Self-citationSub-Hertz Optical Frequency Comparisons between Two TrappedYb+171Ions
Schneider, T., Peik, E., & Tamm, C. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.230801 · Cited by 204
Laser-Cooled Mercury Ion Frequency Standard
Berkeland, D. J., Miller, J. D., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.2089 · Cited by 196
Self-citationDestabilization of dark states and optical spectroscopy in Zeeman-degenerate atomic systems
Berkeland, D. J., & Boshier, M. G. (2002) · Physical Review A · doi:10.1103/physreva.65.033413 · Cited by 188
Electric Quadrupole Shift Cancellation in Single-Ion Optical Frequency Standards
Dubé, P., Madej, A. A., Bernard, J. E., Marmet, L., Boulanger, J.-S., & Cundy, S. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.033001 · Cited by 152
Ramond, T. M., Diddams, S. A., Hollberg, L. W., & Bartels, A. (2002) · Optics Letters · doi:10.1364/ol.27.001842 · Cited by 124
Self-citationGill, P. R. (2005) · Metrologia · doi:10.1088/0026-1394/42/3/s13 · Cited by 122
Bartels, A., & Kurz, H. G. (2002) · Optics Letters · doi:10.1364/ol.27.001839 · Cited by 99
Total variance, an estimator of long-term frequency stability [standards]
Greenhall, C. A., Howe, D. A., & Percival, D. B. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.796124 · Cited by 88
Measurement of the Electric Quadrupole Moment of the 4d D5/22 Level in Sr+88
Barwood, G. P., Margolis, H. S., Huang, G., Gill, P. R., & Klein, H. A. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.133001 · Cited by 79
Oskay, W. H., Itano, W. M., & Bergquist, J. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.163001 · Cited by 74
Self-citation
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450
Self-citationAn optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Frequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
Molecular fingerprinting with the resolved modes of a femtosecond laser frequency comb
Diddams, S. A., Hollberg, L., & Mbele, V. (2007) · Nature · doi:10.1038/nature05524 · Cited by 805
Self-citation
Metadata
- Authors
- Oskay, W. H., Diddams, S. A., Donley, E. A., Fortier, T. M., Heavner, T. P., Hollberg, L., Itano, W. M., Jefferts, S. R., Delaney, M. J., Kim, K., Levi, F., Parker, T. E., & Bergquist, J. C.
- Venue
- Physical Review Letters
- Publisher
- American Physical Society (APS)
- Published
- 2006-07-14
- Volume
- 97
- Issue
- 2
- Pages
- 020801-020801
- ISSN
- 0031-9007 (ISSN-L)
- 1079-7114
- OpenAlex
- W2083197100
- Cited by
- 297
- References
- 26
- FWCI
- 31.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.