The DOI matches its Crossref record; 123 of the 123 references it cites were found in a registry or an index.
Heavy-ion tumor therapy: Physical and radiobiological benefits
Abstract
High-energy beams of charged nuclear particles (protons and heavier ions) offer significant advantages for the treatment of deep-seated local tumors in comparison to conventional megavolt photon therapy. Their physical depth-dose distribution in tissue is characterized by a small entrance dose and a distinct maximum (Bragg peak) near the end of range with a sharp fall-off at the distal edge. Taking full advantage of the well-defined range and the small lateral beam spread, modern scanning beam systems allow delivery of the dose with millimeter precision. In addition, projectiles heavier than protons such as carbon ions exhibit an enhanced biological effectiveness in the Bragg peak region caused by the dense ionization of individual particle tracks resulting in reduced cellular repair. This makes them particularly attractive for the treatment of radio-resistant tumors localized near organs at risk. While tumor therapy with protons is a well-established treatment modality with more than 60 000 patients treated worldwide, the application of heavy ions is so far restricted to a few facilities only. Nevertheless, results of clinical phase I-II trials provide evidence that carbon-ion radiotherapy might be beneficial in several tumor entities. This article reviews the progress in heavy-ion therapy, including physical and technical developments, radiobiological studies and models, as well as radiooncological studies. As a result of the promising clinical results obtained with carbon-ion beams in the past ten years at the Heavy Ion Medical Accelerator facility (Japan) and in a pilot project at GSI Darmstadt (Germany), the plans for new clinical centers for heavy-ion or combined proton and heavy-ion therapy have recently received a substantial boost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SRIM – The stopping and range of ions in matter (2010)
Ziegler, J. F., Ziegler, M. D., & Biersack, J. P. (2010) · Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2010.02.091 · Cited by 11,412 · cited 1×
“Fano, 1963; Ahlen, 1980; Sigmund, 2004; Ziegler et al., 2008".”
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Zur Theorie des Durchgangs schneller Korpuskularstrahlen durch Materie
Bethe, H. (1930) · Annalen der Physik · doi:10.1002/andp.19303970303 · Cited by 4,076
The linear-quadratic formula and progress in fractionated radiotherapy
Fowler, J. F. (1989) · The British Journal of Radiology · doi:10.1259/0007-1285-62-740-679 · Cited by 2,252
Monoenergetic beams of relativistic electrons from intense laser–plasma interactions
Mangles, S. P. D., Murphy, C. D., Najmudin, Z., Thomas, A. G. R., Collier, J. L., Dangor, A. E., Divall, E. J., Foster, P. S., Gallacher, J. G., Hooker, C. J., et al. (2004) · Nature · doi:10.1038/nature02939 · Cited by 1,977
ACTION OF X-RAYS ON MAMMALIAN CELLS
Puck, T. T., & Marcus, P. I. (1956) · The Journal of Experimental Medicine · doi:10.1084/jem.103.5.653 · Cited by 1,696 · cited 1×
“Puck and Marcus, 1956", cell proliferation is analyzed about 1–2 weeks after irradiation and cells are counted as survivors, if they have formed a colony with more than 50 daughter cells.”
BackgroundRadiological Use of Fast Protons
Wilson, R. R. (1946) · Radiology · doi:10.1148/47.5.487 · Cited by 1,403
Relative biological effectiveness (RBE) values for proton beam therapy
Paganetti, H., Niemierko, A., Ancukiewicz, M., Gerweck, L. E., Goitein, M., Loeffler, J. S., & Suit, H. D. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02754-2 · Cited by 1,364
Intensity-modulated radiation therapy, protons, and the risk of second cancers
Hall, E. J. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.01.027 · Cited by 1,110
The calibration of CT Hounsfield units for radiotherapy treatment planning
Schneider, U., Pedroni, E., & Lomax, A. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/009 · Cited by 1,093
Penetration of Protons, Alpha Particles, and Mesons
Fano, U. (1963) · Annual Review of Nuclear Science · doi:10.1146/annurev.ns.13.120163.000245 · Cited by 1,074
Cycling hypoxia and free radicals regulate angiogenesis and radiotherapy response
Dewhirst, M. W., Cao, Y., & Moeller, B. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2397 · Cited by 1,022
Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy
Kanai, T., Endo, M., Minohara, S., Miyahara, N., Koyama-ito, H., Tomura, H., Matsufuji, N., Futami, Y., Fukumura, A., Hiraoka, T., et al. (1999) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(98)00544-6 · Cited by 889
Zur Bremsung rasch bewegter Teilchen beim Durchgang durch Materie
Bloch, F. (1933) · Annalen der Physik · doi:10.1002/andp.19334080303 · Cited by 867
(2016) · Diagnostic Imaging: Nuclear Medicine · doi:10.1016/b978-0-323-37753-9.50111-0 · Cited by 855
Bragg, W., & Kleeman, R. D. (1905) · The London Edinburgh and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786440509463378 · Cited by 838
Bremsverm�gen von Atomen mit mehreren Elektronen
Bloch, F. (1933) · Zeitschrift f�r Physik · doi:10.1007/bf01344553 · Cited by 804
Pair production and bremsstrahlung of charged leptons
Tsai, Y.-S. (1974) · Reviews of Modern Physics · doi:10.1103/revmodphys.46.815 · Cited by 740
Magnetic scanning system for heavy ion therapy
Haberer, T., Becher, W., Schardt, D., & Kraft, G. (1993) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(93)91335-k · Cited by 730
Self-citationPark, C., Papiez, L., Zhang, S., Story, M., & Timmerman, R. D. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.10.059 · Cited by 651
Theoretical and experimental aspects of the energy loss of relativistic heavily ionizing particles
Ahlen, S. P. (1980) · Reviews of Modern Physics · doi:10.1103/revmodphys.52.121 · Cited by 583
Heavy ion carcinogenesis and human space exploration
Durante, M., & Cucinotta, F. A. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2391 · Cited by 578
Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization
Krämer, M., Jäkel, O., Haberer, T., Kraft, G., Schardt, D., & Weber, U. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/11/313 · Cited by 505
Self-citationFurusawa, Y., Fukutsu, K., Aoki, M., Itsukaichi, H., Eguchi-Kasai, K., Ohara, H., Yatagai, F., Kanai, T., & Ando, K. (2000) · Radiation Research · doi:10.1667/0033-7587(2000)154[0485:ioaahc]2.0.co;2 · Cited by 474
Computation of cell survival in heavy ion beams for therapy
Scholz, M., Kellerer, A. M., Kraft-Weyrather, W., & Kraft, G. (1997) · Radiation and Environmental Biophysics · doi:10.1007/s004110050055 · Cited by 464
Respiratory gated irradiation system for heavy-ion radiotherapy
Minohara, S., Kanai, T., Endo, M., Noda, K., & Kanazawa, M. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00524-1 · Cited by 457
Tumor therapy with heavy charged particles
Kraft, G. (2000) · Progress in Particle and Nuclear Physics · doi:10.1016/s0146-6410(00)00112-5 · Cited by 454
Krämer, M., & Scholz, M. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/11/314 · Cited by 453
Irradiation of Mixed Beam and Design of Spread-Out Bragg Peak for Heavy-Ion Radiotherapy
Kanai, T., Furusawa, Y., Fukutsu, K., Itsukaichi, H., Eguchi-Kasai, K., & Ohara, H. (1997) · Radiation Research · doi:10.2307/3579446 · Cited by 422
Xu, X. G., Bednarz, B., & Paganetti, H. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/13/r01 · Cited by 415
Image-guided Robotic Radiosurgery
Adler, J. R., Murphy, M. J., Chang, S. D., & Hancock, S. L. (1999) · Neurosurgery · doi:10.1097/00006123-199906000-00079 · Cited by 412
Parodi, K., Paganetti, H., Shih, H. A., Michaud, S., Loeffler, J. S., DeLaney, T. F., Liebsch, N. J., Munzenrider, J. E., Fischman, A. J., Knopf, A., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.01.063 · Cited by 409
Lyman, J. T., & Wolbarst, A. B. (1987) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(87)90266-5 · Cited by 365
The radiobiology of prostate cancer including new aspects of fractionated radiotherapy
Fowler, J. F. (2005) · Acta Oncologica · doi:10.1080/02841860410002824 · Cited by 354
Microdosimetric Measurements and Estimation of Human Cell Survival for Heavy-Ion Beams
Kase, Y., Kanai, T., Matsumoto, Y., Furusawa, Y., Okamoto, H., Asaba, T., Sakama, M., & Shinoda, H. (2006) · Radiation Research · doi:10.1667/rr0536.1 · Cited by 352
Quantitative modelling of DNA damage using Monte Carlo track structure method
Nikjoo, H., O'Neill, P., Terrissol, M., & Goodhead, D. T. (1999) · Radiation and Environmental Biophysics · doi:10.1007/s004110050135 · Cited by 334
Rietzel, E., Chen, G. T. Y., Choi, N. C., & Willet, C. G. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.11.037 · Cited by 330
Tracking moving organs in real time
Murphy, M. J. (2004) · Seminars in Radiation Oncology · doi:10.1053/j.semradonc.2003.10.005 · Cited by 330
Inactivation of Cells by Heavy Ion Bombardment
Katz, R., Ackerson, B., Homayoonfar, M., & Sharma, S. C. (1971) · Radiation Research · doi:10.2307/3573247 · Cited by 323
Trends of total reaction cross sections for heavy ion collisions in the intermediate energy range
Kox, S., Gamp, A., Perrin, C., Arvieux, J., Bertholet, R., Bruandet, J. F., Buenerd, M., Cherkaoui, R., Cole, A. J., El-Masri, Y., et al. (1987) · Physical Review C · doi:10.1103/physrevc.35.1678 · Cited by 322
Instrumentation for treatment of cancer using proton and light-ion beams
Chu, W. T., Ludewigt, B. A., & Renner, T. R. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143946 · Cited by 313
Barkas, W. H., Massey, H. S. W., & Yagoda, H. (1964) · Physics Today · doi:10.1063/1.3051477 · Cited by 308
RBE for carbon track-segment irradiation in cell lines of differing repair capacity
K. Weyrather, S. R. (1999) · International Journal of Radiation Biology · doi:10.1080/095530099139232 · Cited by 300
Heavy ion synchrotron for medical use —HIMAC project at NIRS-Japan—
Hirao, Y., Ogawa, H., Yamada, S., Sato, Y., Yamada, T., Sato, K., Itano, A., Kanazawa, M., Noda, K., Kawachi, K., et al. (1992) · Nuclear Physics A · doi:10.1016/0375-9474(92)90803-r · Cited by 296
Effectiveness of Carbon Ion Radiotherapy in the Treatment of Skull-Base Chordomas
Schulz-Ertner, D., Karger, C. P., Feuerhake, A., Nikoghosyan, A., Combs, S. E., Jäkel, O., Edler, L., Scholz, M., & Debus, J. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.12.059 · Cited by 290
Self-citationEfficacy and Safety of Carbon Ion Radiotherapy in Bone and Soft Tissue Sarcomas
Kamada, T., Tsujii, H., Tsuji, H., Yanagi, T., Mizoe, J.-E., Miyamoto, T., Kato, H., Yamada, S., Morita, S., Yoshikawa, K., et al. (2002) · Journal of Clinical Oncology · doi:10.1200/jco.2002.10.050 · Cited by 289
Mechanisms of therapy-related carcinogenesis
Allan, J. M., & Travis, L. B. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1749 · Cited by 277
Microdosimetric structure of heavy ion tracks in tissue
Chatterjee, A., & Schaefer, H. J. (1976) · Radiation and Environmental Biophysics · doi:10.1007/bf01330766 · Cited by 277
Hawkins, R. B. (2003) · Radiation Research · doi:10.1667/rr3010 · Cited by 275
Heavy fragments produced in proton-nucleus and nucleus-nucleus collisions at relativistic energies
Hüfner, J. (1985) · Physics Reports · doi:10.1016/0370-1573(85)90124-3 · Cited by 271
Track structure and the calculation of biological effects of heavy charged particles
Scholz, M., & Kraft, G. (1996) · Advances in Space Research · doi:10.1016/0273-1177(95)00784-c · Cited by 265
Barendsen, G. W., Koot, C. J., van Kersen, G. R., Bewley, D. K., Field, S. B., & Parnell, C. J. (1966) · International Journal of Radiation Biology and Related Studies in Physics, Chemistry and Medicine · doi:10.1080/09553006614550421 · Cited by 259
The heidelberg ion therapy center
Haberer, T., Debus, J., Eickhoff, H., Jäkel, O., Schulz-Ertner, D., & Weber, U. (2004) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(04)80046-x · Cited by 237
Self-citationA Statistical Theory of Cell Killing by Radiation of Varying Linear Energy Transfer
Hawkins, R. B. (1994) · Radiation Research · doi:10.2307/3579114 · Cited by 235
Elsässer, T., Krämer, M., & Scholz, M. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2008.02.037 · Cited by 225
Self-citationAstrahan, M. (2008) · Medical Physics · doi:10.1118/1.2969065 · Cited by 222
INACTIVATION OF HUMAN KIDNEY CELLS BY HIGH-ENERGY MONOENERGETIC HEAVY-ION BEAMS
Blakely, E. A. (1979) · eScholarship (California Digital Library) · Cited by 216
Overview of clinical experiences on carbon ion radiotherapy at NIRS
Tsujii, H., Mizoe, J.-E., Kamada, T., Baba, M., Kato, S., Kato, H., Tsuji, H., Yamada, S., Yasuda, S., Ohno, T., et al. (2004) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(04)80012-4 · Cited by 213
Cluster Effects within the Local Effect Model
Elsässer, T., & Scholz, M. (2007) · Radiation Research · doi:10.1667/rr0467.1 · Cited by 205
Self-citationKato, H., Tsujii, H., Miyamoto, T., Mizoe, J.-E., Kamada, T., Tsuji, H., Yamada, S., Kandatsu, S., Yoshikawa, K., Obata, T., et al. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.01.032 · Cited by 194
Kase, Y., Kanai, T., Matsufuji, N., Furusawa, Y., Elsässer, T., & Scholz, M. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/1/003 · Cited by 178
Self-citationA model of ion track structure based on classical collision dynamics (radiobiology application)
Kiefer, J., & Straaten, H. (1986) · Physics in Medicine and Biology · doi:10.1088/0031-9155/31/11/002 · Cited by 176
Sihver, L., Tsao, C. H., Silberberg, R., Kanai, T., & Barghouty, A. F. (1993) · Physical Review C · doi:10.1103/physrevc.47.1225 · Cited by 174
BELLI F. CERA R. CHERUBINI M. DALLA, M. (1998) · International Journal of Radiation Biology · doi:10.1080/095530098141375 · Cited by 173
Scholz, M., & Kraft, G. (1994) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a082156 · Cited by 170
Gunzert-Marx, K., Iwase, H., Schardt, D., & Simon, R. S. (2008) · New Journal of Physics · doi:10.1088/1367-2630/10/7/075003 · Cited by 166
Self-citationDose quantification from in-beam positron emission tomography
Enghardt, W., Parodi, K., Crespo, P., Fiedler, F., Pawelke, J., & Pönisch, F. (2004) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(04)80024-0 · Cited by 163
Track Effects of Heavy Ions in Liquid Water
LaVerne, J. A. (2000) · Radiation Research · doi:10.1667/0033-7587(2000)153[0487:teohii]2.0.co;2 · Cited by 163
What will it take for laser driven proton accelerators to be applied to tumor therapy?
Linz, U., & Alonso, J. (2007) · Physical Review Special Topics - Accelerators and Beams · doi:10.1103/physrevstab.10.094801 · Cited by 161
Influence of fragment reaction of relativistic heavy charged particles on heavy-ion radiotherapy
Matsufuji, N., Fukumura, A., Komori, M., Kanai, T., & Kohno, T. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/11/309 · Cited by 153
Preclinical biological assessment of proton and carbon ion beams at Hyogo Ion Beam Medical Center
Kagawa, K., Murakami, M., Hishikawa, Y., Abe, M., Akagi, T., Yanou, T., Kagiya, G., Furusawa, Y., Andō, K., Nojima, K., et al. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02949-8 · Cited by 145
Nuclear Fragmentation in Proton- and Heavy-Ion-Induced Reactions
Lynch, W. G. (1987) · Annual Review of Nuclear and Particle Science · doi:10.1146/annurev.ns.37.120187.002425 · Cited by 140
Biochemical Kinetics Model of DSB Repair and Induction of γ-H2AX Foci by Non-homologous End Joining
Cucinotta, F. A., Pluth, J. M., Anderson, J. A., Harper, J. V., & O’Neill, P. (2008) · Radiation Research · doi:10.1667/rr1035.1 · Cited by 139
Rapid calculation of biological effects in ion radiotherapy
Krämer, M., & Scholz, M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/8/001 · Cited by 137
Shapiro, M. M., & Silberberg, R. (1970) · Annual Review of Nuclear Science · doi:10.1146/annurev.ns.20.120170.001543 · Cited by 136
Comparison of Carbon Ions Versus Protons
Weber, U. A., & Kraft, G. (2009) · The Cancer Journal · doi:10.1097/ppo.0b013e3181b01935 · Cited by 121
Recent advances in light ion radiation therapy
Brahme, A. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2003.09.034 · Cited by 118
Carbon ion radiation therapy for prostate cancer: Results of a prospective phase II study
Ishikawa, H., Tsuji, H., Kamada, T., Yanagi, T., Mizoe, J., Kanai, T., Morita, S., Wakatsuki, M., Shimazaki, J., & Tsujii, H. (2006) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2006.08.015 · Cited by 114
Schall, I., Schardt, D., Geissel, H., Irnich, H., Kankeleit, E., Kraft, G., Magel, A., Mohär, M. F., Münzenberg, G., Nickel, F., et al. (1996) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(96)00325-4 · Cited by 113
Self-citationClinical advantages of carbon-ion radiotherapy
Tsujii, H., Kamada, T., Baba, M., Tsuji, H., Kato, H., Kato, S., Yamada, S., Yasuda, S., Yanagi, T., Kato, H., et al. (2008) · New Journal of Physics · doi:10.1088/1367-2630/10/7/075009 · Cited by 111
Modelling of Radiation-induced DNA Damage: The Early Physical and Chemical Event
Nikjoo, H., O'Neill, P., Terrissol, M., & GOODHEAD, D. T. (1994) · International Journal of Radiation Biology · doi:10.1080/09553009414551451 · Cited by 102
Phase I/II clinical trials of carbon ion therapy for prostate cancer
Akakura, K., Tsujii, H., Morita, S., Tsuji, H., Yagishita, T., Isaka, S., Itô, H., Akaza, H., Hata, M., Fujime, Μ., et al. (2003) · The Prostate · doi:10.1002/pros.10328 · Cited by 101
Karger, C. P., Peschke, P., Sanchez-Brandelik, R., Scholz, M., & Debus, J. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.08.045 · Cited by 97
Energy loss of 70 MeV protons in elements
Bischel, H., & Hiraoka, T. (1992) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/0168-583x(92)95995-4 · Cited by 89
Spatial fragment distribution from a therapeutic pencil-like carbon beam in water
Matsufuji, N., Komori, M., Sasaki, H., Akiu, K., Ogawa, M., Fukumura, A., Urakabe, E., Inaniwa, T., Nishio, T., Kohno, T., et al. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/14/014 · Cited by 88
Ito, A., Nakano, H., Kusano, Y., Hirayama, R., Furusawa, Y., Murayama, C., Mori, T., Katsumura, Y., & Shinohara, K. (2006) · Radiation Research · doi:10.1667/rr3557.1 · Cited by 86
Range verification system using positron emitting beams for heavy-ion radiotherapy
Iseki, Y., Kanai, T., Kanazawa, M., KITAGAWA, A., Mizuno, H., Tomitani, T., Suda, M., & Urakabe, E. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/14/012 · Cited by 81
Development of a hospital-based proton beam treatment center
Slater, J. M., Miller, D. W., & Archambeau, J. O. (1988) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(88)90099-5 · Cited by 80
Galactic HZE Propagation through the Earth's Atmosphere
Wilson, J. W., Townsend, L. W., & Badavi, F. F. (1987) · Radiation Research · doi:10.2307/3576944 · Cited by 74
The Fragmentation of 670A MeV Neon-20 as a Function of Depth in Water: I. Experiment
Schimmerling, W., Miller, J., Wong, M., Rapkin, M., Howard, J., Spieler, H., & Jarret, B. V. (1989) · Radiation Research · doi:10.2307/3577634 · Cited by 67
Mouse skin reactions following fractionated irradiation with carbon ions
C, K. A. S. K. K. N. Y.-J. C. (1998) · International Journal of Radiation Biology · doi:10.1080/095530098141799 · Cited by 65
Effects of Ion Radiation on Cells and Tissues
Scholz, M. (2003) · Advances in polymer science · doi:10.1007/3-540-45668-6_4 · Cited by 64
Dosimetry and instrumentation for helium and heavy ions
Lyman, J. T., & Howard, J. (1977) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(77)90231-0 · Cited by 64
Linear Energy Transfer and Track Structure
Kraft, G., & Krämer, M. (1993) · Advances in radiation biology · doi:10.1016/b978-0-12-035417-7.50004-0 · Cited by 62
Dosimetry and Measured Differential W Values of Air for Heavy Ions
Kanai, T., Kohno, T., Minohara, S., Sudou, M., Takada, E., Soga, F., Kawachi, K., & Fukumura, A. (1993) · Radiation Research · doi:10.2307/3578867 · Cited by 59
Neon-20 Depth-dose Relations in Water
Wilson, J. W., Townsend, L. W., Bidasaria, H. B., Schimmerling, W., Wong, M., & Howard, J. (1984) · Health Physics · doi:10.1097/00004032-198405000-00010 · Cited by 54
Nuclear fragmentation of high-energy heavy-ion beams in water
Schardt, D., Schall, I., Geissel, H., Irnich, H., Kraft, G., Magel, A., Mohär, M. F., Münzenberg, G., Nickel, F., Scheidenberger, C., et al. (1996) · Advances in Space Research · doi:10.1016/0273-1177(95)00516-h · Cited by 53
Self-citationRelative Biological Effectiveness
(2008) · Springer eBooks · doi:10.1007/978-1-4020-6754-9_14353 · Cited by 52
A Monte Carlo Code for the Simulation of Heavy-Ion Tracks in Water
Champion, C., L’Hoir, A., Politis, M. F., Fainstein, P. D., Rivarola, R. D., & Chetioui, A. (2005) · Radiation Research · doi:10.1667/rr3295 · Cited by 50
Bichsel, H., Hiraoka, T., & Omata, K. (2000) · Radiation Research · doi:10.1667/0033-7587(2000)153[0208:aofid]2.0.co;2 · Cited by 50
Scaling algorithm to calculate heavy-ion spallation cross sections
Tsao, C. H., Silberberg, R., Barghouty, A. F., Sihver, L., & Kanai, T. (1993) · Physical Review C · doi:10.1103/physrevc.47.1257 · Cited by 47
Fertil, B., Reydellet, I., & Deschavanne, P. (1994) · Radiation Research · doi:10.2307/3578847 · Cited by 47
Koike, S., Andō, K., Oohira, C., et al. (2002) · Journal of Radiation Research · doi:10.1269/jrr.43.247 · Cited by 45
Imaging by Injection of Accelerated Radioactive Particle Beams
Llacer, J., Chatterjee, A., Alpen, E. L., Saunders, W., Andreae, S. W., & Jackson, H. C. (1984) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1984.4307660 · Cited by 44
Biophysical models in ion beam radiotherapy
Scholz, M., & Elsässer, T. (2007) · Advances in Space Research · doi:10.1016/j.asr.2007.02.066 · Cited by 43
Self-citationPetti, P. L., & Lennox, A. (1994) · Annual Review of Nuclear and Particle Science · doi:10.1146/annurev.ns.44.120194.001103 · Cited by 41
Heavy particles in therapy: an application of track theory
Katz, R., & Sharma, S. C. (1974) · Physics in Medicine and Biology · doi:10.1088/0031-9155/19/4/001 · Cited by 38
Brusasco, C., Voss, B., Schardt, D., Krämer, M., & Kraft, G. (2000) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(00)00058-6 · Cited by 36
Self-citationKatz, R., & Cucinotta, F. A. (1999) · Radiation Measurements · doi:10.1016/s1350-4487(99)00098-0 · Cited by 35
Attenuation of cosmic ray heavy nuclei fluxes in the upper atmosphere by fragmentation
Allkofer, O. C., & Heinrich, W. (1974) · Nuclear Physics B · doi:10.1016/0550-3213(74)90193-x · Cited by 33
How important is breathing in radiation therapy of the thorax?
Henkelman, R. M., & Mah, K. (1982) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(82)90462-x · Cited by 32
Shavers, M. R., Frankel, K. A., Miller, J., Schimmerling, W., Townsend, L. W., & Wilson, J. W. (1993) · Radiation Research · doi:10.2307/3578633 · Cited by 32
Shavers, M. R., Curtis, S. B., Miller, J., & Schimmerling, W. (1990) · Radiation Research · doi:10.2307/3577855 · Cited by 32
Radiation Biophysical Studies with Mammalian Cells and a Modulated Carbon Ion Beam
Chapman, J. D., Blakely, E. A., Smith, K. C., Urtasun, R. C., Lyman, J., & Tobias, C. A. (1978) · Radiation Research · doi:10.2307/3574760 · Cited by 31
Fukutsu, K., Kanai, T., Furusawa, Y., & Andō, K. (1997) · Radiation Research · doi:10.2307/3579574 · Cited by 31
Response of Chinese Hamster V79 Multicellular Spheroids Exposed to High-Energy Carbon Ions
Staab, A., Zukowski, D., Walenta, S., Scholz, M., & Mueller-Klieser, W. (2004) · Radiation Research · doi:10.1667/rr3113 · Cited by 30
Tumor Induction in Mice Locally Irradiated with Carbon Ions: A Retrospective Analysis
Andō, K., Koike, S., Oohira, C., Ogiu, T., & Yatagai, F. (2005) · Journal of Radiation Research · doi:10.1269/jrr.46.185 · Cited by 28
Fragmentation of High-Energy Oxygen-Ion Beams in Water
Maccabee, H. D., & Ritter, M. (1974) · Radiation Research · doi:10.2307/3574021 · Cited by 25
Cross Secion Calculations in Condensed Media: Charged Particles in Liquid Water
Dingfelder, M. (2002) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a006770 · Cited by 25
Suzuki, Y. K. M. (2000) · International Journal of Radiation Biology · doi:10.1080/09553000050134429 · Cited by 24
On‐line characterization of heavy‐ion beams with semiconductor detectors
Llacer, J., Tobias, C. A., Holley, W. R., & Kanai, T. (1984) · Medical Physics · doi:10.1118/1.595502 · Cited by 21
Acute Response of Pig Skin to Irradiation with 12C-ions or 200 kV X-rays
Zacharias, T., Dörr, W., Enghardt, W., Haberer, T., Krämer, M., Kumpf, R., Röthig, H., Scholz, M., Weber, U. A., Kraft, G., et al. (1997) · Acta Oncologica · doi:10.3109/02841869709001328 · Cited by 20
Kubota, N., Suzuki, M., Furusawa, Y., Andō, K., Koike, S., Kanai, T., Yatagai, F., Ohmura, M., Tatsuzaki, H., Matsubara, S., et al. (1995) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(95)00029-x · Cited by 15
Cited by
Ion acceleration by superintense laser-plasma interaction
Macchi, A., Borghesi, M., & Passoni, M. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.751 · Cited by 1,460
Newhauser, W. D., & Zhang, R. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/8/r155 · Cited by 675
Physical basis of radiation protection in space travel
Durante, M., & Cucinotta, F. A. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.1245 · Cited by 528
Charged particle therapy—optimization, challenges and future directions
Loeffler, J. S., & Durante, M. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.79 · Cited by 426
Assessing the risk of second malignancies after modern radiotherapy
Newhauser, W. D., & Durante, M. (2011) · Nature Reviews Cancer · doi:10.1038/nrc3069 · Cited by 380
Metadata
- Authors
- Schardt, D., Elsässer, T., & Schulz-Ertner, D.
- Venue
- Reviews of Modern Physics
- Publisher
- American Physical Society (APS)
- Published
- 2010-02-19
- Volume
- 82
- Issue
- 1
- Pages
- 383-425
- ISSN
- 0034-6861 (ISSN-L)
- 1539-0756
- OpenAlex
- W2017529805
- Cited by
- 778
- References
- 123
- FWCI
- 30.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.