Versatile sample environments and automation for biological solution X-ray scattering experiments at the P12 beamline (PETRA III, DESY)
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
A high-brilliance synchrotron P12 beamline of the EMBL located at the PETRA III storage ring (DESY, Hamburg) is dedicated to biological small-angle X-ray scattering (SAXS) and has been designed and optimized for scattering experiments on macromolecular solutions. Scatterless slits reduce the parasitic scattering, a custom-designed miniature active beamstop ensures accurate data normalization and the photon-counting PILATUS 2M detector enables the background-free detection of weak scattering signals. The high flux and small beam size allow for rapid experiments with exposure time down to 30–50 ms covering the resolution range from about 300 to 0.5 nm. P12 possesses a versatile and flexible sample environment system that caters for the diverse experimental needs required to study macromolecular solutions. These include an in-vacuum capillary mode for standard batch sample analyses with robotic sample delivery and for continuous-flow in-line sample purification and characterization, as well as an in-air capillary time-resolved stopped-flow setup. A novel microfluidic centrifugal mixing device (SAXS disc) is developed for a high-throughput screening mode using sub-microlitre sample volumes. Automation is a key feature of P12; it is controlled by a beamline meta server, which coordinates and schedules experiments from either standard or nonstandard operational setups. The integrated SASFLOW pipeline automatically checks for consistency, and processes and analyses the data, providing near real-time assessments of overall parameters and the generation of low-resolution models within minutes of data collection. These advances, combined with a remote access option, allow for rapid high-throughput analysis, as well as time-resolved and screening experiments for novice and expert biological SAXS users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Encyclopedia of Analytical Chemistry: Applications, Theory and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/9780470027318 · Cited by 7,403
(2016) · Encyclopedia of Nanotechnology · doi:10.1007/978-94-017-9780-1_101037 · Cited by 3,780
Svergun, D., Barberato, C., & Koch, M. H. J. (1995) · Journal of Applied Crystallography · doi:10.1107/s0021889895007047 · Cited by 3,434
Self-citationSvergun, D. I. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77443-6 · Cited by 2,221
Self-citationDAMMIF , a program for rapid ab-initio shape determination in small-angle scattering
Franke, D., & Svergun, D. I. (2009) · Journal of Applied Crystallography · doi:10.1107/s0021889809000338 · Cited by 2,021 · cited 2×
“The particle shape is then automatically reconstructed ab initio using DAMMIF (Franke & Svergun, 2009).”
MethodSelf-citationHow fast-folding proteins fold
Lindorff-Larsen, K., Piana, S., Dror, R. O., & Shaw, D. E. (2011) · Science · doi:10.1126/science.1208351 · Cited by 1,980 · cited 1×
“The timescales for the experiments are broad, spanning from the submillisecond range for rapid protein folding events (Kathuria et al., 2011; Lindorff-Larsen et al., 2011) to hours for amyloid 436 Clement E. Blanchet et al. Versatile sample environments and automation J. Appl.”
BackgroundUniqueness of ab initio shape determination in small-angle scattering
Volkov, V. V., & Svergun, D. I. (2003) · Journal of Applied Crystallography · doi:10.1107/s0021889803000268 · Cited by 1,932
Self-citationAutomated matching of high- and low-resolution structural models
Kozin, M. B., & Svergun, D. I. (2001) · Journal of Applied Crystallography · doi:10.1107/s0021889800014126 · Cited by 1,302
Self-citationA low-background-intensity focusing small-angle X-ray scattering undulator beamline
Kirby, N. M., Mudie, S. T., Hawley, A. M., Cookson, D. J., Mertens, H. D. T., Cowieson, N., & Samardzic-Boban, V. (2013) · Journal of Applied Crystallography · doi:10.1107/s002188981302774x · Cited by 530
Small-Angle X-ray Scattering of Polymers
Chu, B., & Hsiao, B. S. (2001) · Chemical Reviews · doi:10.1021/cr9900376 · Cited by 455
Crystal structure of uncleaved ovalbumin at 1·95 Å resolution
Stein, P. E., Leslie, A. G. W., Finch, J. T., & Carrell, R. W. (1991) · Journal of Molecular Biology · doi:10.1016/0022-2836(91)80185-w · Cited by 426
Upgraded ESRF BM29 beamline for SAXS on macromolecules in solution
Pernot, P., Round, A., Barrett, R., De Maria Antolinos, A., Gobbo, A., Gordon, E., Huet, J., Kieffer, J., Lentini, M., Mattenet, M., et al. (2013) · Journal of Synchrotron Radiation · doi:10.1107/s0909049513010431 · Cited by 407
The centrifugal microfluidic Bio-Disk platform
Ducrée, J., Haeberle, S., Lutz, S., Pausch, S., Stetten, F. V., & Zengerle, R. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/7/s07 · Cited by 405
Self-citationDavid, G., & Pérez, J. (2009) · Journal of Applied Crystallography · doi:10.1107/s0021889809029288 · Cited by 371
Pace, C. N., Laurents, D. V., & Thomson, J. A. (1990) · Biochemistry · doi:10.1021/bi00462a019 · Cited by 332
Automated acquisition and analysis of small angle X-ray scattering data
Franke, D., Kikhney, A. G., & Svergun, D. I. (2012) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2012.06.008 · Cited by 305
Self-citationPILATUS: A single photon counting pixel detector for X-ray applications
Henrich, B., Bergamaschi, A., Broennimann, C., Dinapoli, R., Eikenberry, E. F., Johnson, I., Kobas, M., Kraft, P., Mozzanica, A., & Schmitt, B. (2009) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2009.03.200 · Cited by 304
Small-Angle X-Ray Scattering from RNA, Proteins, and Protein Complexes
Lipfert, J., & Doniach, S. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132655 · Cited by 300
How the capillary burst microvalve works
Cho, H., Kim, H.-Y., Kang, J. Y., & Kim, T. S. (2007) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2006.10.077 · Cited by 298
A Helical Structural Nucleus Is the Primary Elongating Unit of Insulin Amyloid Fibrils
Vestergaard, B., Groenning, M., Roessle, M., Kastrup, J. S., de Weert, M. V., Flink, J. M., Frokjaer, S., Gajhede, M., & Svergun, D. I. (2007) · PLoS Biology · doi:10.1371/journal.pbio.0050134 · Cited by 253
Self-citationRoessle, M. W., Klaering, R., Ristau, U., Robrahn, B., Jahn, D., Gehrmann, T., Konarev, P., Round, A., Fiedler, S., Hermes, C., et al. (2007) · Journal of Applied Crystallography · doi:10.1107/s0021889806055506 · Cited by 235
Self-citationRound, A. R., Felisaz, F., Fodinger, L., Gobbo, A., Huet, J., Villard, C., Blanchet, C. E., Pernot, P., McSweeney, S. M., Roessle, M. W., et al. (2014) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s1399004714026959 · Cited by 210
Self-citationSmall-Angle X-Ray Scattering on Biological Macromolecules and Nanocomposites in Solution
Blanchet, C. E., & Svergun, D. I. (2013) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-040412-110132 · Cited by 206
Self-citationImpact and progress in small and wide angle X-ray scattering (SAXS and WAXS)
Graewert, M. A., & Svergun, D. I. (2013) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2013.06.007 · Cited by 189
Self-citationAnisotropic particles align perpendicular to the flow direction in narrow microchannels
Trebbin, M., Steinhauser, D., Perlich, J., Buffet, A., Roth, S. V., Zimmermann, W., Thiele, J., & Förster, S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1219340110 · Cited by 181
Li, Y., Beck, R., Huang, T., Choi, M. C., & Divinagracia, M. (2008) · Journal of Applied Crystallography · doi:10.1107/s0021889808031129 · Cited by 158
Fratzl, P. (2003) · Journal of Applied Crystallography · doi:10.1107/s0021889803000335 · Cited by 149
Jeffries, C. M., Graewert, M. A., Svergun, D. I., & Blanchet, C. E. (2015) · Journal of Synchrotron Radiation · doi:10.1107/s1600577515000375 · Cited by 141
Self-citationLiquid-chromatography-coupled SAXS for accurate sizing of aggregating proteins
Mathew, E., Mirza, A. A., & Menhart, N. (2004) · Journal of Synchrotron Radiation · doi:10.1107/s0909049504014086 · Cited by 140
Round, A. R., Franke, D., Moritz, S., Huchler, R., Fritsche, M., Malthan, D., Klaering, R., Svergun, D. I., & Roessle, M. W. (2008) · Journal of Applied Crystallography · doi:10.1107/s0021889808021018 · Cited by 138
Self-citationSmall-angle x-ray scattering studies of human breast tissue samples
Fernández, M. A., Keyriläinen, J., Serimaa, R. E., et al. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/4/303 · Cited by 124
Advances in Time-Resolved Approaches To Characterize the Dynamical Nature of Enzymatic Catalysis
Callender, R. H., & Dyer, R. B. (2006) · Chemical Reviews · doi:10.1021/cr050284b · Cited by 93
Paris, O., Zizak, I., Lichtenegger, H. C., Roschger, P., Klaushofer, K., & Fratzl, P. (2000) · PubMed · Cited by 81
Chatani, E., Hayashi, R., Moriyama, H., & Ueki, T. (2002) · Protein Science · doi:10.1110/ps.31102 · Cited by 78
Sub-millisecond time-resolved SAXS using a continuous-flow mixer and X-ray microbeam
Graceffa, R., Nobrega, R. P., Barrea, R. A., Kathuria, S. V., Chakravarthy, S., Bilsel, O., & Irving, T. C. (2013) · Journal of Synchrotron Radiation · doi:10.1107/s0909049513021833 · Cited by 73
Blanchet, C. E., Zozulya, A. V., Kikhney, A., Franke, D., Konarev, P. V., Shang, W., Klaering, R., Robrahn, B., Hermes, C., Cipriani, F., et al. (2012) · Journal of Applied Crystallography · doi:10.1107/s0021889812013490 · Cited by 69
Self-citationRound, A. R., Brown, E., Marcelin, R., Kapp, U., Westfall, C. S., Jez, J. M., & Zubieta, C. (2013) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444913019276 · Cited by 50
Software for the high-throughput collection of SAXS data using an enhancedBlu-Ice/DCScontrol system
Classen, S., Rodic, I., Holton, J. M., Hura, G. L., Hammel, M., & Tainer, J. A. (2010) · Journal of Synchrotron Radiation · doi:10.1107/s0909049510028566 · Cited by 44
Chatani, E. (2002) · Protein Science · doi:10.1110/ps.ps.31102 · Cited by 41
Sample holder for small-angle x-ray scattering static and flow cell measurements
Lipfert, J., Millett, I. S., Seifert, S., & Doniach, S. (2006) · Review of Scientific Instruments · doi:10.1063/1.2194484 · Cited by 40
Fislage, M., Brosens, E., Deyaert, E., Spilotros, A., Pardon, E., Loris, R., Steyaert, J., García-Pino, A., & Versées, W. (2014) · Nucleic Acids Research · doi:10.1093/nar/gku213 · Cited by 30
Self-citation
Cited by
Franke, D., Petoukhov, M. V., Konarev, P. V., Panjkovich, A., Tuukkanen, A., Mertens, H. D. T., Kikhney, A. G., Hajizadeh, N. R., Franklin, J. M., Jeffries, C. M., et al. (2017) · Journal of Applied Crystallography · doi:10.1107/s1600576717007786 · Cited by 1,329
Self-citationATSAS 3.0: expanded functionality and new tools for small-angle scattering data analysis
Manalastas-Cantos, K., Konarev, P. V., Hajizadeh, N. R., Kikhney, A. G., Petoukhov, M. V., Molodenskiy, D. S., Panjkovich, A., Mertens, H. D. T., Gruzinov, A., Borges, C., et al. (2021) · Journal of Applied Crystallography · doi:10.1107/s1600576720013412 · Cited by 964
Self-citationHopkins, J. B., Gillilan, R. E., & Skou, S. (2017) · Journal of Applied Crystallography · doi:10.1107/s1600576717011438 · Cited by 646
Trewhella, J., Duff, A. P., Durand, D., Gabel, F., Guss, J. M., Hendrickson, W. A., Hura, G. L., Jacques, D. A., Kirby, N. M., Kwan, A. H., et al. (2017) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798317011597 · Cited by 285
Self-citationSmall-angle X-ray and neutron scattering
Jeffries, C. M., Ilavsky, J., Martel, A., Hinrichs, S., Meyer, A., Pedersen, J. S., Sokolova, A. V., & Svergun, D. I. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00064-9 · Cited by 256
Self-citation
Metadata
- Authors
- Blanchet, C. E., Spilotros, A., Schwemmer, F., Graewert, M. A., Kikhney, A., Jeffries, C. M., Franke, D., Mark, D., Zengerle, R., Cipriani, F., Fiedler, S., Roessle, M., & Svergun, D. I.
- Venue
- Journal of Applied Crystallography
- Published
- 2015-03-12
- Volume
- 48
- Issue
- 2
- Pages
- 431-443
- ISSN
- 0021-8898 (ISSN-L)
- 1600-5767
- OpenAlex
- W2150576297
- Cited by
- 589
- References
- 41
- FWCI
- 18.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.