Methods for haptic feedback in teleoperated robot‐assisted surgery
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Teleoperated minimally invasive surgical robots can significantly enhance a surgeon's accuracy, dexterity and visualization. However, current commercially available systems do not include significant haptic (force and tactile) feedback to the operator. This paper describes experiments to characterize this problem, as well as several methods to provide haptic feedback in order to improve surgeon's performance. There exist a variety of sensing and control methods that enable haptic feedback, although a number of practical considerations, e.g. cost, complexity and biocompatibility, present significant challenges. The ability of teleoperated robot‐assisted surgical systems to measure and display haptic information leads to a number of additional exciting clinical and scientific opportunities, such as active operator assistance through “virtual fixtures” and the automatic acquisition of tissue properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Telerobotics, Automation, and Human Supervisory Control
Sheridan, T. B. (1992) · Medical Entomology and Zoology · Cited by 1,949
A design framework for teleoperators with kinesthetic feedback
Hannaford, B. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.88057 · Cited by 926
Virtual fixtures: Perceptual tools for telerobotic manipulation
Rosenberg, L. B. (1993) · Proceedings of IEEE Virtual Reality Annual International Symposium · doi:10.1109/vrais.1993.380795 · Cited by 578
The role of force feedback in surgery: analysis of blunt dissection
Wagner, C. R., Stylopoulos, N., & Howe, R. D. (2005) · Proceedings 10th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. HAPTICS 2002 · doi:10.1109/haptic.2002.998943 · Cited by 379
Hashtrudi-Zaad, K., & Salcudean, S. E. (2002) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.988981 · Cited by 373
Towards force-reflecting teleoperation over the Internet
Niemeyer, G., & Slotine, J.-J. E. (2002) · Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146) · doi:10.1109/robot.1998.680592 · Cited by 355
The Black Falcon: a teleoperated surgical instrument for minimally invasive surgery
Madhani, A. J., Niemeyer, G., & Salisbury, J. K. (2002) · Proceedings. 1998 IEEE/RSJ International Conference on Intelligent Robots and Systems. Innovations in Theory, Practice and Applications (Cat. No.98CH36190) · doi:10.1109/iros.1998.727320 · Cited by 291
Howe, R. D., & Matsuoka, Y. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.211 · Cited by 282
Application of Haptic Feedback to Robotic Surgery
Bethea, B. T., Okamura, A. M., Kitagawa, M., Fitton, T. P., Cattaneo, S. M., Gott, V. L., Baumgartner, W. A., & Yuh, D. D. (2004) · Journal of Laparoendoscopic & Advanced Surgical Techniques · doi:10.1089/1092642041255441 · Cited by 250
Self-citation
Cited by
Medical robotics in computer-integrated surgery
Taylor, R. H., & Stoianovici, D. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817058 · Cited by 997
Haptic feedback in robot-assisted minimally invasive surgery
Okamura, A. M. (2009) · Current Opinion in Urology · doi:10.1097/mou.0b013e32831a478c · Cited by 708
Self-citationEmerging Robotic Platforms for Minimally Invasive Surgery
Vitiello, V., Lee, S.-L., Cundy, T. P., & Yang, G.-Z. (2013) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2012.2236311 · Cited by 457
Haptics in minimally invasive surgery – a review
Westebring – van der Putten, E. P., Goossens, R. H. M., Jakimowicz, J. J., & Dankelman, J. (2008) · Minimally Invasive Therapy & Allied Technologies · doi:10.1080/13645700701820242 · Cited by 328
Medical Robotics and Computer-Integrated Surgery
Taylor, R. H., Menciassi, A., Fichtinger, G., Fiorini, P., & Dario, P. (2016) · Springer Handbooks · doi:10.1007/978-3-319-32552-1_63 · Cited by 325
Towards Wearability in Fingertip Haptics: A 3-DoF Wearable Device for Cutaneous Force Feedback
Prattichizzo, D., Chinello, F., Pacchierotti, C., & Malvezzi, M. (2013) · IEEE Transactions on Haptics · doi:10.1109/toh.2013.53 · Cited by 292
Russo, M., Sadati, S. M. H., Dong, X., Mohammad, A., Walker, I. D., Bergeles, C., Xu, K., & Axinte, D. A. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200367 · Cited by 263
Haptics in Robot-Assisted Surgery: Challenges and Benefits
Enayati, N., De Momi, E., & Ferrigno, G. (2016) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2016.2538080 · Cited by 252
“misreading these cues is torn tissue or broken suture [17].”
Review of methods for objective surgical skill evaluation
Reiley, C. E., Lin, H. C., Yuh, D. D., & Hager, G. D. (2011) · Surgical Endoscopy · doi:10.1007/s00464-010-1190-z · Cited by 249
“Modified from reference [78] Fig.”
Force Sensor Integrated Surgical Forceps for Minimally Invasive Robotic Surgery
Kim, U., Lee, D.-H., Yoon, W. J., Hannaford, B., & Choi, H. R. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2473515 · Cited by 239
“Forces applied to sutures using a surgical robot were detected to be less than 4 N [25].”
MethodCutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery
Pacchierotti, C., Prattichizzo, D., & Kuchenbecker, K. J. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2455932 · Cited by 235
“However, haptic feedback is still widely believed to be valuable for teleoperated surgical procedures [5]–[9].”
BackgroundEffects of visual force feedback on robot-assisted surgical task performance
Reiley, C. E., Akinbiyi, T., Burschka, D., Chang, D. C., Okamura, A. M., & Yuh, D. D. (2008) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2007.08.043 · Cited by 228
Self-citationHaptic Feedback and Force-Based Teleoperation in Surgical Robotics
Patel, R. V., Atashzar, S. F., & Tavakoli, M. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3180052 · Cited by 200
“However, the number of DoFs for haptic feedback is related to the complexity and cost of the interface and is dictated by the availability of measurements of interaction forces and torques at the end effector of the teleoperated robot [31], [39].”
BackgroundRosbridge: ROS for Non-ROS Users
Crick, C., Jay, G., Osentoski, S., Pitzer, B., & Jenkins, O. C. (2017) · Springer Tracts in Advanced Robotics · doi:10.1007/978-3-319-29363-9_28 · Cited by 198
“Much of the teleoperation work in robotics has traditionally been aimed at tasks where robots operate in environments that are hazardous to human users, such as robotic surgery [18], search and rescue [6], and outer space [2].”
BackgroundIordachita, I., Sun, Z., Balicki, M., Kang, J. U., Phee, S. J., Handa, J., Gehlbach, P., & Taylor, R. (2009) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-009-0301-6 · Cited by 181
“The present program utilizes the steady-hand “Eye Robot” [3,4] and various “sensory substitution” schemes to provide the surgeon with feedback on tool-to-tissue forces that would otherwise be imperceptible [5].”
MethodImproving Collocated Robot Teleoperation with Augmented Reality
Hedayati, H., Walker, M., & Szafir, D. (2018) · Proceedings of the 2018 ACM/IEEE International Conference on Human-Robot Interaction · doi:10.1145/3171221.3171251 · Cited by 165
“As a result, teleoperation is still a dominant paradigm for human-robot interaction in many domains, including the operation of surgical robots for medical purposes [29, 30, 39], robotic manipulators in space exploration [22], and aerial robots for disaster response [32].”
BackgroundInfluentialSoft Wearable Skin-Stretch Device for Haptic Feedback Using Twisted and Coiled Polymer Actuators
Chossat, J.-B., Chen, D. K. Y., Park, Y.-L., & Shull, P. B. (2019) · IEEE Transactions on Haptics · doi:10.1109/toh.2019.2943154 · Cited by 73
“Correspondingly, tasks requiring high degrees of hand-eye coordination strongly benefit from recreating or supplementing the sense of touch through haptic feedback [4], [6].”
BackgroundMullenbach, J., Peshkin, M., & Colgate, J. E. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2016.2630057 · Cited by 43
Atashzar, S. F., Shahbazi, M., Tavakoli, M., & Patel, R. V. (2017) · The International Journal of Robotics Research · doi:10.1177/0278364916689139 · Cited by 41
“(2007), Simorov et al. (2012), and Hapticsenabled Robotic Rehabilitation systems (HRR) Blank et al.”
BackgroundActive and efficient motor skill learning method used in a haptic teleoperated system
Garcia-Hernandez, N., & Parra-Vega, V. (2009) · RO-MAN 2009 - The 18th IEEE International Symposium on Robot and Human Interactive Communication · doi:10.1109/roman.2009.5326132 · Cited by 9
Metadata
- Authors
- Okamura, A. M.
- Venue
- Industrial Robot: An International Journal
- Publisher
- Emerald
- Published
- 2004-12-01
- Volume
- 31
- Issue
- 6
- Pages
- 499-508
- ISSN
- 0143-991X (ISSN-L)
- OpenAlex
- W2070328658
- Cited by
- 493
- References
- 22
- FWCI
- 12.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.