Joint-Angle Measurement Using Accelerometers and Gyroscopes—A Survey
The DOI matches its Crossref record; 13 of the 14 references it cites were found in a registry or an index.
Abstract
This paper presents an analysis of rigid-body joint-angle measurement based on microelectromechanical-system (MEMS) biaxial accelerometers and uniaxial gyroscopes. In comparison to conventional magnetic and optical joint angular sensors, this new inertial sensing principle has the advantages of flexible installation and true contactless sensing. This paper focuses on the comparison of four different inertial-sensor combination methods that are reported in reference papers and utilizes the theory of rigid-body kinematics to explain and analyze their advantages and weaknesses. Experiments have also been conducted to further verify and strengthen the arguments put forward in the analysis. All experiments in this paper took place on a custom-built rigid-body robot arm model that can be manipulated by hand. Sensor calibration and accelerometer alignment issues are also described, and their details are discussed. The experiment results presented in this paper show significant differences with reference to the achieved angular accuracy for various situations when using the four different sensor combination methods. In some cases, the angular error based on one method is more than 0.04 rad, while that from another method is within ±0.005 rad. The noise levels of angular readings from different methods are also experimentally compared and analyzed. The conclusion drawn serves to guide readers toward a suitable method for their particular application.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Integrating advanced sensors enable real-time capture of user motion data and physiological signals such as joint angles 1,2 , acceleration 3,4 , electromyography (EMG) [5][6][7] , electrocardiography (ECG) 8,9 , and electroencephalography (EEG) 10 , providing high-quality and diverse raw data support for HMIP.”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [2]
In the citing paper
“Analyze motion state by detecting mechanical | changes such as acceleration and angular | velocity.”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [2]
Citations
Cites
Mayagoitia, R. E., Nene, A. V., & Veltink, P. H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00231-7 · Cited by 655 · cited 1×
“Different papers define this threshold value in different ways: [6] sets a threshold on the variance of measured acceleration, [7] sets thresholds on both the variance and the frequency of the measured acceleration, [8] did not mention this threshold setting at all, and [9] sets a threshold value on the magnitude diff…”
BackgroundDejnabadi, H., Jolles, B. M., & Aminian, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851475 · Cited by 286 · cited 1×
“D. CMRGD This method is reported in [ 10 ]. It uses the same hardware setup as in the CMRGI method but with a different algorithm.”
MethodDejnabadi, H., Jolles, B. M., Casanova, E., Fua, P., & Aminian, K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873678 · Cited by 189 · cited 1×
“Different papers define this threshold value in different ways: [6] sets a threshold on the variance of measured acceleration, [7] sets thresholds on both the variance and the frequency of the measured acceleration, [8] did not mention this threshold setting at all, and [9] sets a threshold value on the magnitude diff…”
BackgroundDetecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes
Williamson, R., & Andrews, B. J. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345283 · Cited by 185 · cited 1×
“Different papers define this threshold value in different ways: [6] sets a threshold on the variance of measured acceleration, [7] sets thresholds on both the variance and the frequency of the measured acceleration, [8] did not mention this threshold setting at all, and [9] sets a threshold value on the magnitude diff…”
BackgroundLower extremity angle measurement with accelerometers-error and sensitivity analysis
Willemsen, A. T. M., Frigo, C., & Boom, H. B. K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.137284 · Cited by 92 · cited 1×
“This method is reported in [11] and [12] and requires two biaxial accelerometers on both Li and Li−1 to calculate the joint angle θi.”
MethodPrecision calibration of fiber-optics gyroscopes for mobile robot navigation
Ojeda, L., Chung, H., & Borenstein, J. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2000.846333 · Cited by 54 · cited 1×
“... φi and φi−1 to calculate θi. When any Li starts moving, the change in its orientation angle ϕi is calculated by numerically integrating its gyroscope’s reading until the movement stops, and then, φi from the accelerometer is again used as ϕi. The numerical integration in this method also provides the typical probl…”
MethodA Method for Gait Analysis in a Daily Living Environment by Body-Mounted Instruments
Ohtaki, Y., Sagawa, K., & Inooka, H. (2001) · JSME International Journal Series C · doi:10.1299/jsmec.44.1125 · Cited by 52 · cited 1×
“Different papers define this threshold value in different ways: [6] sets a threshold on the variance of measured acceleration, [7] sets thresholds on both the variance and the frequency of the measured acceleration, [8] did not mention this threshold setting at all, and [9] sets a threshold value on the magnitude diff…”
BackgroundDesign and Calibration of an Integration-Free Accelerometer-Based Joint-Angle Sensor
Ghassemi, F., Tafazoli, S., Lawrence, P. D., & Hashtrudi-Zaad, K. (2007) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.904488 · Cited by 31 · cited 6×
“There is a lack of an error model in [3] and [ 4 ] for the method that they used.”
BackgroundMethodInfluentialJoint motion monitoring by accelerometers set at both near sides around the joint
Kurata, S., Makikawa, M., Kobayashi, H., Takahashi, A., & Tokue, R. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1998.746978 · Cited by 29 · cited 2×
“The methods presented in this paper are based on the rigid-body kinematics model, so the experimental results cannot directly be related to nonrigid conditions such as those for the human body in [5]–[12].”
BackgroundMethodAn accelerometer-based joint angle sensor for heavy-duty manipulators
Ghassemi, F., Tafazoli, S., Lawrence, P. D., & Hashtrudi-Zaad, K. (2003) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2002.1014798 · Cited by 29
Research works printed but not linked: 5
- 2008, KXR94-2050
- 0, ADXRS612
- 0, ADS1274
- 0, Vert-X 22-24V
- 0, URM80CC
Cited by
IMU-Based Joint Angle Measurement for Gait Analysis
Seel, T., Raisch, J., & Schauer, T. (2014) · Sensors · doi:10.3390/s140406891 · Cited by 867
“, [7] and the references therein, that inertial measurement data can be used to calculate hinge joint angles when at least one IMU is attached to each side of the joint.”
BackgroundAn Indirect Eavesdropping Attack of Keystrokes on Touch Screen through Acoustic Sensing
Yu, J., Lu, L., Chen, Y., Zhu, Y., & Kong, L. (2021) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2019.2947468 · Cited by 181
“On the other hand, the angle a between the projection plane and plane passing through the central axes of the two smartphones can be estimated with the accelerometer and gyroscope through rotating the adversary’s smartphone from the projection plane to another plane [20].”
BackgroundA Self‐Powered Angle Sensor at Nanoradian‐Resolution for Robotic Arms and Personalized Medicare
Wang, Z., An, J., Nie, J., Luo, J., Shao, J., Jiang, T., Chen, B., Tang, W., & Wang, Z. L. (2020) · Advanced Materials · doi:10.1002/adma.202001466 · Cited by 177
Luo, H., Wang, M., Wong, P. K.-Y., & Cheng, J. C. P. (2020) · Automation in Construction · doi:10.1016/j.autcon.2019.103016 · Cited by 165
Research development of silicon MEMS gyroscopes: a review
Zhanshe, G., Cheng, F., Li, B., Le, C., Lu, C., & Ke, S. (2015) · Microsystem Technologies · doi:10.1007/s00542-015-2645-x · Cited by 145
Metadata
- Authors
- Cheng, P., & Oelmann, B.
- Affiliations
- Mid Sweden University (SE)
- Venue
- IEEE Transactions on Instrumentation and Measurement
- Published
- 2010-02
- Volume
- 59
- Issue
- 2
- Pages
- 404-414
- ISSN
- 0018-9456 (ISSN-L)
- 1557-9662
- OpenAlex
- W2116716880
- Cited by
- 140
- References
- 14
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 9 · 2023: 6 · 2022: 5 · 2021: 9 · 2020: 7 · 2019: 12 · 2018: 5 · 2017: 13 · 2016: 10 · 2015: 16 · 2014: 12 · 2013: 10 · 2012: 9
- FWCI
- 11.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Instrumentation and Measurement (publishedVersion)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Engineering › Control and Systems Engineering › Robotic Mechanisms and Dynamics
- Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
- Keywords
- joint angle measurement, MEMS accelerometer, MEMS gyroscope, inertial sensors, sensor fusion, rigid body kinematics, non-contact sensing, sensor calibration, angular accuracy, angular noise, robot manipulators
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Joint-Angle Measurement Using Accelerometers and Gyroscopes—A Survey. https://app.cochat.ai/papers/10.1109/tim.2009.2024367
- The paper
- Cheng, P., & Oelmann, B. (2010). Joint-Angle Measurement Using Accelerometers and Gyroscopes—A Survey. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2009.2024367
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.