The DOI matches its Crossref record.
Closed-loop class E transcutaneous power and data link for MicroImplants
Abstract
Magnetic transcutaneous coupling is frequently used for power and data transfer to implanted electronic devices. The proposed development of MicroImplants, small enough to be injected through a hypodermic needle suggest the need for a high-efficiency magnetic transcutaneous link. This paper describes the use of a multifrequency transmitter coil driver based upon the Class E topology. The development of a "high-Q approximation" which simplifies the design procedure is presented. A closed-loop controller to compensate for transmitter and receiver variations, and a method of data modulation, using synchronous frequency shifting are described. The closed-loop Class E circuit shows great promise, especially for circuits with unusually low coefficients of coupling. Currents of several amperes, at radio frequencies, can easily and efficiently be obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Robust wireless power transfer using a nonlinear parity–time-symmetric circuit
Assawaworrarit, S., Yu, X., & Fan, S. (2017) · Nature · doi:10.1038/nature22404 · Cited by 812
Wearable and implantable wireless sensor network solutions for healthcare monitoring
Darwish, A., & Hassanien, A. E. (2011) · Sensors · doi:10.3390/s110605561 · Cited by 556
Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
Wang, G., Liu, W., Sivaprakasam, M., & Kendir, G. A. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.852923 · Cited by 435
Retinal Prosthesis for the Blind
Margalit, E., Maia, M., Weiland, J. D., Greenberg, R. J., Fujii, G. Y., Torres, G., Piyathaisere, D. V., O'Hearn, T. M., Liu, W., Lazzi, G., et al. (2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00311-9 · Cited by 427
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
A neuro-stimulus chip with telemetry unit for retinal prosthetic device
Liu, W., Vichienchom, K., Clements, M., DeMarco, S. C., Hughes, C., McGucken, E., Humayun, M. S., De Juan, E., Weiland, J. D., & Greenberg, R. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.871327 · Cited by 371
Xue, R.-F., Cheng, K.-W., & Je, M. (2013) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2012.2209297 · Cited by 340
Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems
Baker, M. W., & Sarpeshkar, R. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.893180 · Cited by 317
Wireless Power Transmission With Self-Regulated Output Voltage for Biomedical Implant
Ahn, D., & Hong, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2273472 · Cited by 315
BION ™ system for distributed neural prosthetic interfaces
Loeb, G. E., Peck, R. A., Moore, W. H., & Hood, K. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00011-x · Cited by 243
“A feedback circuit consisting of an adjustable phase shift and zero-crossing detector compensates for propagation delays in the drive circuitry and shifts in resonant frequency that may result from deformation of the coil (introduced by Troyk and Schwan [19]; new circuit shown in Fig.”
BackgroundA multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
Maynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126
Low-Power Circuits for Brain–Machine Interfaces
Sarpeshkar, R., Wattanapanitch, W., Arfin, S. K., Rapoport, B. I., Mandal, S., Baker, M. W., Fee, M. S., Musallam, S., & Andersen, R. A. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003198 · Cited by 91
Inductive link design for medical implants
Ali, H., Ahmad, T. J., & Khan, S. A. (2009) · 2009 IEEE Symposium on Industrial Electronics & Applications · doi:10.1109/isiea.2009.5356376 · Cited by 41
Metadata
- Authors
- Troyk, P. R., & Schwan, M. A. K.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1992-06
- Volume
- 39
- Issue
- 6
- Pages
- 589-599
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2148032039
- Cited by
- 177
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.