Recruitment data for nerve cuff electrodes: implications for design of implantable stimulators
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Recruitment characteristics of nerve cuff electrodes implanted in four cats for five months were measured. Monopolar, bipolar, and tripolar configurations were considered. Approximately twice the current was required to achieve a given response using the tripolar configuration as compared with monopolar stimulation. Bipolar stimulation also required more current than monopolar stimulation. Using the recruitment data, a number of strategies for modulating muscle tension were considered. It was shown that both pulse amplitude and pulse duration should be software-selectable to achieve adequate control of muscle tension when using either pulse amplitude modulation or pulse duration modulation. When using pulse amplitude modulation, it was found to be desirable to operate at a low pulse duration in the high end of the allowable range for pulse amplitude. For pulse duration modulation, one should operate at a low pulse amplitude in the high end of the allowable range for pulse duration. The effect of pulse amplitude and pulse duration step size on the maximum step change in muscle tension and the linearity of the recruitment curves were examined. The use of logarithmic steps in the modulation parameter was examined and was shown to result in improved controllability and linearity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313
Waters, R. L., McNeal, D. R., Faloon, W., & Clifford, B. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567050-00016 · Cited by 156
Self-citationCrago, P. E., Peckham, P. H., Mortimer, J. T., & Van Der Meulen, J. P. (1974) · Annals of Biomedical Engineering · doi:10.1007/bf02368496 · Cited by 133
Diaphragm pacing by electrical stimulation of the phrenic nerve
Glenn, W. W., & Phelps, M. L. (1985) · Neurosurgery · doi:10.1097/00006123-198512000-00021 · Cited by 15
Cited by
Stimulus waveforms for selective neural stimulation
Grill, W. M., & Mortimer, J. T. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.395310 · Cited by 280
Yamaguchi, G. T., & Zajac, F. E. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.58599 · Cited by 275
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234
The effect of stimulus pulse duration on selectivity of neural stimulation
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.481985 · Cited by 215
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
“Stimulation, on the other hand, has been very successful with the latter configuration [29,44,45].”
Background(2000) · PubMed · Cited by 50
ICFEM 2000. Third IEEE International Conference on Formal Engineering Methods
(2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867869 · Cited by 20
Wu, Y., & Guo, L. (2020) · Neural Interface Engineering · doi:10.1007/978-3-030-41854-0_5 · Cited by 3
Metadata
- Authors
- McNeal, D. R., Baker, L. L., & Symons, J. T.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1989-03
- Volume
- 36
- Issue
- 3
- Pages
- 301-308
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2139665805
- Cited by
- 35
- References
- 4
- FWCI
- 0.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.