Abstract

A percutaneous intramuscular electrode was developed for controlling paralyzed extremities by FES. The electrode was made of a Teflon-coated 19 strand rope wound from ultrafine SUS 316L stainless steel wires and was helically coiled for giving high flexibility. Because of low percentages of electrode failure in the body, stable and reliable FES was achieved for a long time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.32102

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 17

  1. handa, 1987, EMG-based stimulation patterns of FES for the paralyzed upper extremities, Proc 9th Int Symp ECHE, 329
  2. 10.1007/978-94-009-3361-3_6 · DOI
  3. 10.1109/10.32108 · DOI · Paper page
  4. handa, 1987, Percutaneous electrode for restoration of upper extremity function by FES, IEEE/9th Ann Conf EMBS, 1374
  5. handa, 1986, Studies on percutaneous wire electrode for FNS, IECE Japan
  6. marsolais, 1986, Implantation techniques and experience with percutaneous intramuscular electrodes in the lower extremities, J Rehab Res Develop, 23, 1
  7. peckham, 1987, Intramuscular electrode for neuromuscular stimulation, IEEE/9th Ann Conf EMBS, 1569
  8. bibel, 1987, Artificial nerves designed with ultrafine stranded wire, Wire J Intern, 32
  9. 10.1007/BF02363440 · DOI
  10. schwanda, 1983, Requirements for the first implantation of a 16-channel stimulation device in humans, Prog Artific Org, 2, 942
  11. nathan, 1984, The development of a computerized upper limb electrical stimulation system, Der Orthop�de, 7, 1170
  12. 10.1016/S0363-5023(80)80076-1 · DOI · Paper page
  13. handa, 1984, Electrically induced hand movements and their application for daily living, Proc 7th Int Symp ECHE, 169
  14. 10.1109/TBME.1987.325979 · DOI · Paper page
  15. marsolais, 1987, Functional electrical stimulation for walking in paraplegia, J Bone Joint Surg, 69 a, 729
  16. 10.1097/00003086-198305000-00005 · DOI · Paper page
  17. handa, 1985, A voice-controlled functional electrical stimulation system for the paralyzed hand, Japan J MEBE, 23, 292

Cited by

See all 98

Metadata

Authors
Handa, Y., Hoshimiya, N., Iguchi, Y., & Oda, T.
Venue
IEEE Transactions on Biomedical Engineering
Published
1989-07
Volume
36
Issue
7
Pages
705-710
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2112212331
Cited by
98
References
0
FWCI
1.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of percutaneous intramuscular electrode for multichannel FES system. https://app.cochat.ai/papers/10.1109/10.32102
The paper
Handa, Y., Hoshimiya, N., Iguchi, Y., & Oda, T. (1989). Development of percutaneous intramuscular electrode for multichannel FES system. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.32102

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.