The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Surface-marker cluster design criteria for 3-D bone movement reconstruction
Abstract
When three-dimensional (3-D) human or animal movement is recorded using a photogrammetric system, bone-embedded frame positions and orientations are estimated from reconstructed surface marker trajectories using either nonoptimal or optimal algorithms. The effectiveness of these mathematical procedures in accommodating for both photogrammetric errors and skin movement artifacts depends on the number of markers associated with a given bone as well as on the size and shape characteristics of the relevant cluster. One objective of this paper deals with the identification of marker-cluster design criteria aimed at the minimization of error propagation from marker coordinates to bone-embedded frame position and orientation. Findings allow for the quantitative estimation of these errors for any given cluster configuration and suggest the following main design criteria. A cluster made up of four markers represents a good practical compromise. Planar clusters are acceptable, provided in quasi-isotropic distribution. The root mean square distance of the markers from their centroid should be greater than ten times the standard deviation of the marker position error. The second objective of this paper deals with the identification of the optimal cluster position and orientation on the limb aimed at the minimization of error propagation to anatomical landmark laboratory coordinates. Cluster position should be selected to minimize skin movement artifacts. The longest principal axis of the marker distribution should be oriented toward the relevant anatomical landmark position.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Least-Squares Fitting of Two 3-D Point Sets
Arun, K. S., Huang, T. S., & Blostein, S. D. (1987) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1987.4767965 · Cited by 3,952
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Cappozzo, A., Catani, F., Della Croce, U., & Leardini, A. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)91394-t · Cited by 1,677
Self-citationVaughan, C. L., Davis, B. L., & O’Connor, J. (1992) · Medical Entomology and Zoology · Cited by 798
A study of lower-limb mechanics during stair-climbing.
Andriacchi, T. P., Andersson, G. B., Fermier, R. W., Stern, D., & Galante, J. O. (1980) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198062050-00008 · Cited by 765
Position and orientation in space of bones during movement: experimental artefacts
Cappozzo, A., Catani, F., Leardini, A., Benedetti, M., & Della Croce, U. (1996) · Clinical Biomechanics · doi:10.1016/0268-0033(95)00046-1 · Cited by 756
Self-citationDetermining the movements of the skeleton using well-configured markers
Söderkvist, I., & Wedin, P.-Å. (1993) · Journal of Biomechanics · doi:10.1016/0021-9290(93)90098-y · Cited by 735
Medical image matching-a review with classification
van den Elsen, P. A., Pol, E.-J. D., & Viergever, M. A. (1993) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.195938 · Cited by 718
Rigid body motion calculated from spatial co-ordinates of markers
Spoor, C. W., & Veldpaus, F. E. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90020-2 · Cited by 579
Woltring, H. J., Huiskes, R., de Lange, A., & Veldpaus, F. E. (1985) · Journal of Biomechanics · doi:10.1016/0021-9290(85)90293-3 · Cited by 468
Biometrics, biomathematics and the morphometric synthesis
Bookstein, F. L. (1996) · Bulletin of Mathematical Biology · doi:10.1007/bf02458311 · Cited by 456
A procedure for determining rigid body transformation parameters
Challis, J. H. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00116-l · Cited by 398
A least-squares algorithm for the equiform transformation from spatial marker co-ordinates
Veldpaus, F. E., Woltring, H. J., & Dortmans, L. J. M. G. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90190-x · Cited by 376
Cappozzo, A. (1984) · Human Movement Science · doi:10.1016/0167-9457(84)90004-6 · Cited by 361
Self-citation3-D attitude representation of human joints: A standardization proposal
Woltring, H. J. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90191-0 · Cited by 251
A solidification procedure to facilitate kinematic analyses based on video system data
Chèze, L., Fregly, B. J., & Dimnet, J. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)95278-d · Cited by 222
Three-dimensional rotation of the elbow
Chao, E. Y. S., & Morrey, B. F. (1978) · Journal of Biomechanics · doi:10.1016/0021-9290(78)90044-1 · Cited by 138
Woltring, H. J., Long, K., Osterbauer, P. J., & Fuhr, A. W. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90192-9 · Cited by 133
Modelling of the biomechanics of posture and balance
Riley, P. O., Mann, R. W., & Hodge, W. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90306-n · Cited by 124
Analysis of Measurements Based on the Singular Value Decomposition
Hanson, R. J., & Norris, M. J. (1981) · SIAM Journal on Scientific and Statistical Computing · doi:10.1137/0902029 · Cited by 98
Optimization and smoothing techniques in movement analysis
Cappello, A., Palombara, P. F. L., & Leardini, A. (1996) · International Journal of Bio-Medical Computing · doi:10.1016/0020-7101(96)01167-1 · Cited by 77
Self-citationChallis, J. H. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)91877-j · Cited by 38
Cited by
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
Self-citationAbnormal Rotational Knee Motion during Running after Anterior Cruciate Ligament Reconstruction
Tashman, S., Collon, D., Anderson, K., Kolowich, P., & Anderst, W. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503261709 · Cited by 722
Human movement analysis using stereophotogrammetry
Chiari, L., Croce, U. D., Leardini, A., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.04.004 · Cited by 441
Self-citationWearable soft sensing suit for human gait measurement
Mengüç, Y., Park, Y.-L., Pei, H., Vogt, D., Aubin, P. M., Winchell, E., Fluke, L., Stirling, L., Wood, R. J., & Walsh, C. J. (2014) · The International Journal of Robotics Research · doi:10.1177/0278364914543793 · Cited by 415
Mündermann, L., Corazza, S., & Andriacchi, T. P. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-6 · Cited by 387
Metadata
- Authors
- Cappozzo, A., Cappello, A., Croce, U. D., & Pensalfini, F.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1997
- Volume
- 44
- Issue
- 12
- Pages
- 1165-1174
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2119274204
- Cited by
- 456
- References
- 22
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.