The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Performance of planar multisite microprobes in recording extracellular single-unit intracortical activity
Abstract
The microprobes consist of a thin-film electrode array supported by a silicon micromachined substrate and insulated using deposited dielectrics. Microprobes with multiple recording sites spaced from 30 mu m to 200 mu m apart are used to record spontaneous single-unit activity from rat cerebral cortex. Additionally, a theoretical model is used to establish a basis for interpreting the multisite single-unit data. The results suggest that the microprobes (1) couple tightly to the neural tissue with relatively little disturbance to the neural system, (2) facilitate the identification of single units in multiunit records through the use of spatially-separate recording sites, and (3) can be used to detect the cell position in tissue and observe events such as the propagation of electrical activity from the soma to the dendritic tree.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Self-citationElectrophysiology of a Dendritic Neuron Model
Rall, W. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86953-7 · Cited by 492
The electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 464
The physiology of neuroglial cells
Kuffler, S. W., & Nicholls, J. G. (1966) · Ergebnisse der Physiologie Biologischen Chemie und Experimentellen Pharmakologie · doi:10.1007/bf02259903 · Cited by 462
The physiology of neuroglial cells
Kuffler, S. W., & Nicholls, J. G. (2007) · Ergebnisse der Physiologie Biologischen Chemie und Experimentellen Pharmakologie · doi:10.1007/bfb0116991 · Cited by 416
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
Self-citationA high-yield IC-compatible multichannel recording array
Najafi, K., Wise, K. D., & Mochizuki, T. (1985) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1985.22102 · Cited by 301
Self-citationPotentials recorded from the spinal cord with microelectrodes
Frank, K., & Fuortes, M. G. F. (1955) · The Journal of Physiology · doi:10.1113/jphysiol.1955.sp005432 · Cited by 196
Solid-State Electrodes for Multichannel Multiplexed Intracortical Neuronal Recording
BeMent, S. L., Wise, K. D., Anderson, D. J., Najafi, K., & Drake, K. L. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325895 · Cited by 145
Self-citationTerzuolo, C. A., & Araki, T. (1961) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1961.tb35558.x · Cited by 127
A Practical 24 Channel Microelectrode for Neural Recording in Vivo
Kuperstein, M., & Whittington, D. A. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324702 · Cited by 74
Research works printed but not linked: 7
- najafi, 1987, Multichannel intracortical recording microprobes: Scaling limitations, device characteristics, and circuit encapsulation, Dig 4th Int Conf Solid-State Sensors Actuators, 65
- 10.1109/TBME.1973.324175 · doi:10.1109/tbme.1973.324175
- rail, 0, Handbook of Physiology Section 1 The Nervous System, 1, 39
- smith, 1978, Numerical Solution of Partial Differential Equations Finite Difference Methods
- najafi, 1986, Multielectrode Intracortical Recording Arrays with On-Chip Signal Processing
- drake, 1987, A Planar multisite microprobe for recording simultaneous single-unit cortical activity
- kuffler, 1984, From Neuron to Brain
Cited by
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Harris, K. D., Henze, D. A., Csicsvari, J., Hirase, H., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.401 · Cited by 1,151
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Barthó, P., Hirase, H., Monconduit, L., Zugaro, M., Harris, K. D., & Buzsáki, G. (2004) · Journal of Neurophysiology · doi:10.1152/jn.01170.2003 · Cited by 887
Metadata
- Authors
- Drake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1988
- Volume
- 35
- Issue
- 9
- Pages
- 719-732
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2030275688
- Cited by
- 362
- References
- 11
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.