The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Performance of planar multisite microprobes in recording extracellular single-unit intracortical activity
Abstract
The microprobes consist of a thin-film electrode array supported by a silicon micromachined substrate and insulated using deposited dielectrics. Microprobes with multiple recording sites spaced from 30 mu m to 200 mu m apart are used to record spontaneous single-unit activity from rat cerebral cortex. Additionally, a theoretical model is used to establish a basis for interpreting the multisite single-unit data. The results suggest that the microprobes (1) couple tightly to the neural tissue with relatively little disturbance to the neural system, (2) facilitate the identification of single units in multiunit records through the use of spatially-separate recording sites, and (3) can be used to detect the cell position in tissue and observe events such as the propagation of electrical activity from the soma to the dendritic tree.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544
Self-citationElectrophysiology of a Dendritic Neuron Model
Rall, W. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86953-7 · Cited by 492
The electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 464
The physiology of neuroglial cells
Kuffler, S. W., & Nicholls, J. G. (1966) · Ergebnisse der Physiologie Biologischen Chemie und Experimentellen Pharmakologie · doi:10.1007/bf02259903 · Cited by 462
The physiology of neuroglial cells
Kuffler, S. W., & Nicholls, J. G. (2007) · Ergebnisse der Physiologie Biologischen Chemie und Experimentellen Pharmakologie · doi:10.1007/bfb0116991 · Cited by 416
An implantable multielectrode array with on-chip signal processing
Najafi, K., & Wise, K. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052646 · Cited by 310
Self-citationA high-yield IC-compatible multichannel recording array
Najafi, K., Wise, K. D., & Mochizuki, T. (1985) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1985.22102 · Cited by 301
Self-citationPotentials recorded from the spinal cord with microelectrodes
Frank, K., & Fuortes, M. G. F. (1955) · The Journal of Physiology · doi:10.1113/jphysiol.1955.sp005432 · Cited by 196
Solid-State Electrodes for Multichannel Multiplexed Intracortical Neuronal Recording
BeMent, S. L., Wise, K. D., Anderson, D. J., Najafi, K., & Drake, K. L. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325895 · Cited by 145
Self-citationTerzuolo, C. A., & Araki, T. (1961) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1961.tb35558.x · Cited by 127
Research works printed but not linked: 7
- najafi, 1987, Multichannel intracortical recording microprobes: Scaling limitations, device characteristics, and circuit encapsulation, Dig 4th Int Conf Solid-State Sensors Actuators, 65
- 10.1109/TBME.1973.324175 · doi:10.1109/tbme.1973.324175
- rail, 0, Handbook of Physiology Section 1 The Nervous System, 1, 39
- smith, 1978, Numerical Solution of Partial Differential Equations Finite Difference Methods
- najafi, 1986, Multielectrode Intracortical Recording Arrays with On-Chip Signal Processing
- drake, 1987, A Planar multisite microprobe for recording simultaneous single-unit cortical activity
- kuffler, 1984, From Neuron to Brain
Cited by
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Harris, K. D., Henze, D. A., Csicsvari, J., Hirase, H., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.401 · Cited by 1,151
Intracellular Features Predicted by Extracellular Recordings in the Hippocampus In Vivo
Henze, D. A., Borhegyi, Z., Csicsvari, J., Mamiya, A., Harris, K. D., & Buzsáki, G. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.1.390 · Cited by 942
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Barthó, P., Hirase, H., Monconduit, L., Zugaro, M., Harris, K. D., & Buzsáki, G. (2004) · Journal of Neurophysiology · doi:10.1152/jn.01170.2003 · Cited by 887
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
Brain responses to micro-machined silicon devices
Szarowski, D. H., Andersen, M. D., Retterer, S., Spence, A. J., Isaacson, M., Craighead, H. G., Turner, J. N., & Shain, W. (2003) · Brain Research · doi:10.1016/s0006-8993(03)03023-3 · Cited by 796
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Quantitative measures of cluster quality for use in extracellular recordings
Schmitzer-Torbert, N., Jackson, J., Henze, D., Harris, K., & Redish, A. D. (2005) · Neuroscience · doi:10.1016/j.neuroscience.2004.09.066 · Cited by 662
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Self-citationNeural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638
Intensity versus Identity Coding in an Olfactory System
Stopfer, M., Jayaraman, V., & Laurent, G. (2003) · Neuron · doi:10.1016/j.neuron.2003.08.011 · Cited by 610
Cerebral Astrocyte Response to Micromachined Silicon Implants
Turner, J. N., Shain, W., Szarowski, D. H., Andersen, M., Martins, S., Isaacson, M., & Craighead, H. (1999) · Experimental Neurology · doi:10.1006/exnr.1998.6983 · Cited by 592
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Cui, X., & Martin, D. C. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00448-3 · Cited by 573
A Neuron-Silicon Junction: A Retzius Cell of the Leech on an Insulated-Gate Field-Effect Transistor
Fromherz, P., Offenhäusser, A., Vetter, T., & Weis, J. (1991) · Science · doi:10.1126/science.1925540 · Cited by 563
Surface modification of neural recording electrodes with conducting polymer/biomolecule blends
Cui, X., Lee, V. A., Raphael, Y., Wiler, J. A., Hetke, J. F., Anderson, D. J., & Martin, D. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200108)56:2<261::aid-jbm1094>3.0.co;2-i · Cited by 530
Self-citationImplanted Neural Interfaces: Biochallenges and Engineered Solutions
Grill, W. M., Norman, S. E., & Bellamkonda, R. V. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124927 · Cited by 488
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral Cortex
Vetter, R. J., Williams, J. C., Hetke, J. F., Nunamaker, E. A., & Kipke, D. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826680 · Cited by 475
Transcranial Electric Stimulation Entrains Cortical Neuronal Populations in Rats
Ozen, S., Sirota, A., Belluscio, M. A., Anastassiou, C. A., Stark, E., Koch, C., & Buzsáki, G. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.5252-09.2010 · Cited by 425
Multifunctional Nanobiomaterials for Neural Interfaces
Abidian, M. R., & Martin, D. C. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801473 · Cited by 416
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
Massively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
Self-citationWilliams, J. C., Rennaker, R. L., & Kipke, D. R. (1999) · Brain Research Protocols · doi:10.1016/s1385-299x(99)00034-3 · Cited by 395
Kipke, D. R., Vetter, R. J., Williams, J. C., & Hetke, J. F. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814443 · Cited by 367
Single unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358
Biran, R., Martin, D. C., & Tresco, P. A. (2007) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31138 · Cited by 341
Microfabricated Microneedles for Gene and Drug Delivery
McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.289 · Cited by 335
Tools for Probing Local Circuits: High-Density Silicon Probes Combined with Optogenetics
Buzsáki, G., Stark, E., Berényi, A., Khodagholy, D., Kipke, D. R., Yoon, E., & Wise, K. D. (2015) · Neuron · doi:10.1016/j.neuron.2015.01.028 · Cited by 334
Self-citationCui, X., Hetke, J. F., Wiler, J. A., Anderson, D. J., & Martin, D. C. (2001) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00637-9 · Cited by 330
Self-citationMicrofabrication Techniques for Integrated Sensors and Microsystems
Wise, K. D., & Najafi, K. (1991) · Science · doi:10.1126/science.1962192 · Cited by 309
Self-citationUsing noise signature to optimize spike-sorting and to assess neuronal classification quality
Pouzat, C., Mazor, O., & Laurent, G. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00276-5 · Cited by 308
Prasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298
Polytrodes: High-Density Silicon Electrode Arrays for Large-Scale Multiunit Recording
Blanche, T. J., Spacek, M. A., Hetke, J. F., & Swindale, N. V. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01023.2004 · Cited by 282
A multichannel neural probe for selective chemical delivery at the cellular level
Chen, J., Wise, K. D., Hetke, J. F., & Bledsoe, S. C. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.605435 · Cited by 280
Self-citationSelective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Relationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
Multiplexed, High Density Electrophysiology with Nanofabricated Neural Probes
Du, J., Blanche, T. J., Harrison, R. R., Lester, H. A., & Masmanidis, S. C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026204 · Cited by 231
“d; Figure 7B), which is in good agreement with other extracellular recordings with comparable electrode properties [11,16].”
MethodResultRecent advances in neurotechnologies with broad potential for neuroscience research
Vázquez-Guardado, A., Yang, Y., Bandodkar, A. J., & Rogers, J. A. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-00739-8 · Cited by 202
Implantable microscale neural interfaces
Cheung, K. C. (2007) · Biomedical Microdevices · doi:10.1007/s10544-006-9045-z · Cited by 202
Jimbo, Y., Robinson, H. P. C., & Kawana, A. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.238465 · Cited by 192
Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178
Silicon ribbon cables for chronically implantable microelectrode arrays
Hetke, J. F., Lund, J. L., Najafi, K., Wise, K. D., & Anderson, D. J. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284959 · Cited by 174
Self-citationAzemi, E., Lagenaur, C. F., & Cui, X. T. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.033 · Cited by 164
Barrese, J. C., Aceros, J., & Donoghue, J. P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026003 · Cited by 161
Strength characterization of silicon microprobes in neurophysiological tissues
Najafi, K., & Hetke, J. F. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55638 · Cited by 146
Ceramic-Based Multisite Electrode Arrays for Chronic Single-Neuron Recording
Moxon, K. A., Leiser, S., Gerhardt, G. A., Barbee, K. A., & Chapin, J. K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821037 · Cited by 129
Maynard, E. M. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.145 · Cited by 126
Electrical stimulation and recording from cultured neurons using a planar electrode array
Jimbo, Y., & Kawana, A. (1992) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(92)80067-q · Cited by 126
A wafer-scale etching technique for high aspect ratio implantable MEMS structures
Bhandari, R., Negi, S., Rieth, L., & Solzbacher, F. (2010) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2010.06.011 · Cited by 71
Flavopiridol reduces the impedance of neural prostheses in vivo without affecting recording quality
Purcell, E. K., Thompson, D. E., Ludwig, K. A., & Kipke, D. R. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.06.026 · Cited by 62
A low-profile three-dimensional neural probe array using a silicon lead transfer structure
Cheng, M.-Y., Je, M., Tan, K. L., Tan, E. L., Lim, R., Yao, L., Li, P., Park, W.-T., Phua, E. J. R., Gan, C. L., et al. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/9/095013 · Cited by 18
Metadata
- Authors
- Drake, K. L., Wise, K. D., Farraye, J., Anderson, D. J., & BeMent, S. L.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1988
- Volume
- 35
- Issue
- 9
- Pages
- 719-732
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2030275688
- Cited by
- 362
- References
- 11
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.